4. Maintenance

 

E

   - Remove the screws for the battery

cover.
 

F

   - Remove the cover.

Reinstallation of the battery module

Carry out the above operation in reverse order.

 To maintain an identical level of performance and safety, use a battery module identical to that previously

mounted in the UPS.

 Press the two parts of the battery connector tightly together to ensure proper connection.

 

G

   - Remove the battery units and replace

them.

F

E

100%

80%

50%

20%

test

%

1

2

%

BYPA

SS

G

G

100%

80%

50%

20%

test

%

1

2

%

BYPA

SS

Summary of Contents for Pulsar EXtreme 2200C

Page 1: ...34007532EN AA Page 1 www mgeups com MGE UPS SYSTEMS Installation and user manual Pulsar EXtreme 2200C 3200C T H E U N I N T E R R U P T I B L E P O W E R P R O V I D E R ...

Page 2: ...PS MGE UPS SYSTEMS pays great attention to the environmental impact of its products Measures that have made Pulsar EXtreme C a reference in environmental protection include the eco design approach used in product developmen recycling of Pulsar EXtreme C at the end of its service life To discover the entire range of MGE UPS SYSTEMS products and the options available for the Pulsar EXtreme C range w...

Page 3: ...nformation advice help Visual indication Action Audio indication In the illustrations on the following pages the symbols below are used LED off LED on LED flashing Information may be found primarily by consulting the contents the index Pictograms Foreword Using this document ...

Page 4: ...Page 4 34007532EN AA ...

Page 5: ...12 2 4 Connection to the RS232 or USB communications port optional 13 2 5 Installation of the communications card option 13 2 6 Connections 14 3 operation 3 1 Start up 15 3 2 Bargraph indications 15 3 3 Operation on battery power following failure of AC input power 16 Transfer to battery power 16 Threshold for the low battery warning 16 End of backup time 16 3 4 Personalisation optional 17 Functio...

Page 6: ...Page 6 34007532EN AA Contents 4 Maintenance 4 1 Troubleshooting 20 4 2 Replacement of the battery module 22 5 Environment 24 6 Appendices 6 1 Technical characteristics 25 6 2 Glossary 26 6 3 Index 27 ...

Page 7: ...tions Rack position Tower position Pulsar EXtreme 2200C 35 3 Kg Pulsar EXtreme 3200C 35 7 Kg 654 mm 438 mm 19 86 5 mm 2U www mgeups com P U L S A R E X t r e m e 100 80 50 20 test 1 2 BYPASS P U L S A R EXtreme www mgeups com 100 80 50 20 test 1 2 BYPASS ...

Page 8: ...for automatic detection of an additional battery module Pushbutton to test phase neutral inversion of AC power source LED indicating phase neutral inversion of AC power source Connector for remote power off Battery module connectors to the UPS or to other battery modules Connectors for automatic detection of additional battery modules Circuit breaker for battery ON OFF and protection 1 2 3 4 5 6 7...

Page 9: ...N LINE mode backup power available Status of programmable outlet 2 Operation on battery power Supplied with power Status change in progress 16 17 18 19 20 21 22 23 25 24 Press simultaneously at least 3 seconds to reset the End of battery life alarm load 100 80 50 20 27 26 UPS overload Electronics fault Battery fault flashing LED buzzer battery fault battery must be replaced flashing LED long buzze...

Page 10: ... cords for connection of the protected equipment RS232 communications cable USB communications cable Telescopic rails for mounting in 19 bay with mounting hardware Securing system for equipment power cords CD ROM with the Solution Pac and UPS Driver software Product documentation Two supports for the upright position 31 32 33 29 28 29 30 31 32 30 28 33 35 36 35 36 34 34 P U L S A R EXtreme www mge...

Page 11: ...on Follow steps 1 to 6 for rack mounting of the UPS on the rails The rails and the necessary mounting hardware are supplied by MGE UPS SYSTEMS Note for step 3 It is possible to adjust the positions of the front brackets 1 2 5 3 3 4 2 6 2 2 100 80 50 20 test 1 2 BYPAS S ...

Page 12: ...7532EN AA 2 3 Installation in tower position 2 Installation Connect the two supports for the upright position P U L S A R E X t r e m e P U L S A R EXtreme www mgeups com www mgeups com 100 80 50 20 test 1 2 BYPASS ...

Page 13: ...B 3 communications port on the UPS The UPS can now communicate with all MGE UPS SYSTEMS supervision set up or safety software 30 31 The RS232 and USB communications ports cannot operate simultaneously 2 5 Installation of the communications card option It is not necessary to shut down the UPS to install the communications card 1 Remove the slot 1 cover secured by two screws 2 Insert the card in the...

Page 14: ...AC power wall outlet 3 Connect the protected equipment to the UPS using the two cords 29 It is advised to connect priority loads to the four outlets 4 and any non priority loads to the two programmable outlets 5 If the UPS is connected to a computer running MGE UPS SYSTEMS communications software it is possible to program the interruption of power to the two programmable outlets 5 during operation...

Page 15: ...three different indications 1 Remaining backup time in percent during normal operation 2 Percent load drawn by the protected equipment when button 23 is pressed 3 Operating faults flashing LED and beeps 27 Overload 26 UPS fault 25 Battery fault or end of life warning Status LEDs 20 and 21 for programmable outlets 1 and 2 LEDs OFF the outlets are not supplied with power LEDs flashing status change ...

Page 16: ...very little remaining battery backup time Close all applications because UPS automatic shutdown is imminent End of backup time The buzzer sounds continuously Press button 22 to turn the buzzer OFF The equipment is no longer supplied with power The UPS goes to sleep mode at the end of the battery backup time until complete shutdown due to tripping of the battery protection function against deep dis...

Page 17: ...ROM containing the UPS Driver software in the computer drive 2 Open the Windows file manager or explorer and select the CD drive 3 Run Emb Config UPSDRVxx exe where xx is the software version It is also possible to download the UPS Driver software from the www mgeups com site Once the UPS Driver software has been installed the parameters listed below can be modified Battery tab Personalisable func...

Page 18: ...20 V 240 V 250 V Converter 60 Hz F 1 to 10 in 1 steps 0 to 110 in 10 steps Enabled click to add check Personalisable function Transfer to bypass if overload Transfer to bypass following a fault whatever the conditions on the AC power source Default setting Enabled Disabled Options Disabled click to remove check Enabled click to add check Output tab Bypass tab 3 5 UPS shutdown Press button 16 retur...

Page 19: ...n 1 Check that the UPS is shut off and disconnected to the AC power source 2 Remove the RPO connector 12 by undoing the screws 37 3 Connect an insulated dry contact NC 60 V DC 30 V AC max 20 mA max cable size 0 75 mm2 to the two terminals of the RPO connector 38 4 Put the RPO connector 12 back in place on the back of the UPS 5 Connect the UPS to the AC power source and restart it as indicated prev...

Page 20: ...etected during the automatic battery test The battery has reached the theoretical end of its service life The function for monitoring the phase and neutral position of your electrical network has detected a reversal Correction Check the power drawn by the equipment and disconnect any non priority devices Check that the battery connector is fully pushed in Replace battery module see the Maintenance...

Page 21: ...g on the UPS personalisation parameters see section 3 4 there are two possibilities the equipment connected to the UPS continues to be supplied but directly from the AC power source via the automatic bypass LED 19 ON the connected equipment is no longer supplied The equipment connected to the UPS is no longer protected Correction Check that there is not a short circuit on the outlets Eliminate any...

Page 22: ...ve all watches rings bracelets and any other metal objects use tools with insulated handles Removal of battery module A Slide a finger in the slot to remove the MGE UPS SYSTEMS logo from the front of the UPS B Remove the two screws C Remove the left side of the front panel D Remove the connector B A www mgeups com P U L S A R E X t r e m e 100 80 50 20 test 1 2 BYPAS S C D P U L S A R E X t r e m ...

Page 23: ... operation in reverse order To maintain an identical level of performance and safety use a battery module identical to that previously mounted in the UPS Press the two parts of the battery connector tightly together to ensure proper connection G Remove the battery units and replace them F E 100 80 50 20 test 1 2 BYPAS S G G 100 80 50 20 test 1 2 BYPAS S ...

Page 24: ...es and in compliance with all applicable regulations all UPS products recovered at the end of their service life contact your MGE UPS SYSTEMS branch office Packing UPS packing materials must be recycled in compliance with all applicable regulations Warning This product contains lead acid batteries Lead is a dangerous substance for the environment if it is not properly recycled by specialised compa...

Page 25: ... Hz auto selection 0 95 Single phase 230 V 3 2 50 60 Hz 5 3 4 for linear loads 6 for non linear loads 110 continuous 130 for 12 seconds 130 for 1 5 seconds 6 x 12 V 7 Ah sealed lead acid maintenance free 6 x 12 V 9 Ah sealed lead acid maintenance free 50 dBA 0 to 40 C 20 to 90 without condensation IEC EN 62040 1 1 EN 60950 1 RD IEC EN 62040 3 EN 50091 2 IEC 62040 2 class B IEC 61000 4 2 3 4 6 8 11...

Page 26: ...erated by continuous double conversion i e the AC power from the AC power source is rectified AC DC then converted back DC AC to AC power Equipment Devices or systems connected to the UPS output Forced shutdown Ten second interruption in the supply of power to the connected equipment following a system shutdown even if AC input power returns during the interruption period Percent load Ratio betwee...

Page 27: ...ications card 13 RS232 communications port 13 USB communications port 13 Communication 8 13 D Dimensions 7 E Environment 2 24 Excessive ambient temperature 25 F Forced shutdown 17 L Lamp test 9 LEDs 8 9 O ON LINE mode 9 Overload 9 18 20 P Personnalisation 17 Battery 17 By pass 18 On Off conditions 17 Output 18 Programmable outlets 8 9 15 S Sleep mode 17 Automatic restart 17 18 Start up 15 T Techni...

Page 28: ...Page 28 34007532EN AA ...

Reviews: