background image

Pulsar EX : 51032278XT/AB

MGE UPS SYSTEMS

note

c

 this equipment has been tested and found to comply with Part 15 of the FCC Rules. These limits are designed to provide reasonable protection

against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate
radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio
communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to
correct the interference at his own expense.

service and factory repair - call 1 - 800 - 523 - 0142

c

 direct questions about the operation, repair, or servicing of this equipment to MGE UPS SYSTEMS, Inc. Customer Support Services. Include

the part number, assembly number, and serial number of the unit in any correspondence. Should you require factory service for your equipment,
contact MGE UPS SYSTEMS, Inc. Customer Support Services and obtain a Return Materials Authorization (RMA) prior to shipping your unit.
Never ship equipment to MGE UPS SYSTEMS, Inc. without first obtaining an RMA.

proprietary rights statement

c

 the information in this manual is the property of MGE UPS SYSTEMS, Inc., and represents a proprietary article in which MGE UPS SYSTEMS,

Inc., retains any and all patent rights, including exclusive rights of use and/or manufacture and/or sale. Possession of this information does not
convey any permission to reproduce, print, or manufacture the article or articles shown herein. Such permission may be granted only by specific
written authorization, signed by an officer of MGE UPS SYSTEMS, Inc.;

c

 IBM, PC-AT, ES/9000, and AS/400 are trademarks of International Business Machines Corporation. Other trademarks that may be used herein

are owned by their respective companies and are referred to in an editorial fashion only.

two years warranty policy

c

 MGE UPS SYSTEMS, Inc. (herein after referred to as MGE) warrants Topaz and Pulsar equipment manufactured by MGE to be free from

defects in materials and workmanship for a period of two years from date of purchase. If within such period purchaser discovers defective item
and promptly notifies MGE in writing, MGE shall repair or replace the item at the Company's option. This warranty shall not apply:

v

 to equipment not manufactured by MGE,

v

 to equipment repaired or altered by others than MGE,

v

 to equipment subjected to negligence, accident, or damage by circumstances beyond MGE's control, or to improper operations, maintenance,

or storage, or to other than normal use or service.
With respect to equipment not manufactured by MGE, the Warranty obligations of MGE shall in all respects conform and Warranties do not cover
reimbursement for labor, transportation, removal, installation, or other expenses which may be incurred in connection with repairs or replacement.
Except as may be expressly provided in an authorized writing by MGE, MGE shall not be subject to any other obligations or liabilities whatsoever
with respect to equipment manufactured by MGE or service rendered by MGE. After Sales Service Support Line: 1-800-523-0142.

Summary of Contents for Pulsar EX20

Page 1: ...Manuel d utilisation User Manual Manual de instrucciones PulsarTM EX20 EX30 EXB20 30 Pulsar EX20...

Page 2: ...decemos la compra del SAI EX Lo invitamos a leer este manual esperando que ste le brindar todos los elementos necesarios para la instalaci n y la utilizaci n de su SAI EX Cont ctenos al siguiente n me...

Page 3: ...convey any permission to reproduce print or manufacture the article or articles shown herein Such permission may be granted only by specific written authorization signed by an officer of MGE UPS SYST...

Page 4: ...Postal address 1660 Scenic Avenue Costa Mesa CA 92626 714 557 1636 MGE UPS SYSTEMS Inc 51032278XT AB...

Page 5: ...ies in a fire The battery may explode c CAUTION do not open or mutilate the battery or batteries released electrolyte is harmful to the skin and eyes It may be toxic c CAUTION a battery can present a...

Page 6: ...urbances on computer systems range from data losses to hardware damage power supplies hard disks Pulsar EX20 and EX30 are specially designed to protect network servers and all other interconnection de...

Page 7: ...ur requirements c isolation transformer input line cord plugs into the Pulsar EX30 output receptacle Rating is 120V AC input 208V 240V AC 2 75 kVA output c maintenance bypass switch enables the user t...

Page 8: ...recording of events in a log file v during long term power outages automatic shutdown of the system and of the UPS followed by automatic restart of the UPS system reboot on return of utility power v P...

Page 9: ...general contents sommaire g n ral sumario general Pulsar presentation 3 pr sentation de Pulsar presentaci n de Pulsar english 11 getting started operation fran ais 19 mise en service exploitation esp...

Page 10: ...sta trasera CIRCUIT BREAKER 120Vdc 40A 19 23 Volt 96Vdc 20A Volt 96Vdc 20A 22 20 21 solution pac 17 CIRCUIT BREAKER 30A 125V T INPUT U TALK 10 12 13 5 I max 15A Vac OUT SITE WIRING FAULT 8 11 EXT BATT...

Page 11: ...contents getting started 12 location 12 preliminary checks 12 connections 12 communication 13 operation 14 starting up with utility power present 14 starting up with out utility power 15 operation on...

Page 12: ...onnect the input connection cord v flip the circuit breaker of the battery unit to the right position O v connect the battery connection cord to the DC connector of the battery module and connect to t...

Page 13: ...to COM4 set up by EX Tuner series port of your computer equipped with Windows 3 1 on the one end and to the serial Pulsar EX connector on the other end Insert the disk and type A Install Follow the i...

Page 14: ...s beep output off output off normal operation indicator lights test press button on off automatic sequence your load is supported by the battery 1a to 1f flashing device and battery test indicating t...

Page 15: ...tion on battery indicator lights test press on off button automatic sequence your load is supported by the battery 1a to 1f flashing UPS is on utility power device and battery test indicating the rema...

Page 16: ...ing on battery or when site wiring fault occured Note 2 The function button allows you to force a transfer on bypass push three times within 5 seconds and to come back on normal operation push again t...

Page 17: ...the following occurs recharge your battery for 8 hours 1c flashing 1e off 1f on 1 beep every second operation on bypass see overload and device fault section Note This operating mode provides temporar...