1 - INTRODUCTION

The CPO optical counting sensor is a detection tool which, thanks to its sensitivity and 
adjustment characteristics, is the answer to all counting problems for objects in any 
material or shape, both free falling and forced.
It also offers the opportunity not to count objects in sizes under those desired, such as 
machining waste for example, which could accidentally cross the reading area.

2 – WARNINGS

- ATTENTION: for correct use of the equipment, it is essential to comply with the

instructions in this manual. You are advised to read each part of it carefully before
start-up, to prevent possible damage due to improper actions.

- The equipment MUST NEVER be used as a detection device to protect people.
-   Do   not   use   the   equipment   in   environments   with   a   dangerous   atmosphere

(inflammable or explosive).

- Only use in enclosed environments not subject to water sprays.
-  Avoid   fumes   or   mist   passing   through   the   reading   area,   which   could   cause   false

readings or detection loss.

- The power supply must comply with the operating voltage planned and it is preferred

not   to   share   such   supply   with   motors,   relays   or   solenoids   whose   activation   could
reduce sensitivity or cause false detections.

- Connect the body of the sensor to the ground, using the best support to reject external

electrical disturbance.

- Avoid sunlight or stroboscopic flashes directly striking the equipment.

 

3 – ELECTRICAL CHARACTERISTICS

Voltage supply

10-30Vdc, o  12Vac

Current supply

100mA   tipical 30mA

Outputs

PNP o NPN max 24Vdc 100mA

Outputs protection

Overvoltage and overcurrent

Signal delay

< 1mS

Signal duration

> 15mS < 1Sec. (other than sensor block signal)

Max. count

100pz/Sec.

Errors

Signalled on output and with optical indication

4 – MECHANICAL CHARACTERISTICS

2