background image

Fluxa A - with arm

Area floodlight for wall-
or pole mounting

Area floodlight for metal halide lamps

HIT-DE, HIT-DE-CE,

high pressure sodium lamps HST-DE

70 / 150 Watts, lampholder Rx7s.

MOUNTING INSTRUCTIONS

Light fitting is suitable for installation on

normal inflammable building materials.

Attention ! High Voltage !

Disconnect power supply before opening

light fitting or changing lamp.

Ensure that the correct size of pole is chosen;

if necessary consult the pole manufacturer.

Loosen screws in front frame. Lift frame and

glass and swing away from casing.

Depending on height of pole, take

a sufficiently long piece of cable

and insert it through the cable gland.

Strip the sheathing off the last 9 cm

of cable and slide the enclosed silicone

sleeves over the individual wires.

ATTENTION ! Do not insert more than 2 cm

of sheathed cable into luminaire housing.

Make the electrical connection.

Screw cable gland tight. Insert lamp, taking

care to use the correct lamp as mentioned

on the rating plate. If a high pressure sodium

lamp is to be used, make sure that only

lamps bearing the

- sign are used.

Connect the light fitting in compliance with

prevailing regulations in your country.

Swing front frame and glass back onto

casing and screw down evenly.

Hang the luminaire onto the M10 x 40

screws on the pole top fitter and tighten with

44 Nm torque. The threaded inserts in the

pole top fitter are self locking.

Push cable through hole in pole and

connect to connection box in base of pole.

Mounting on pole top fitter

Luminaire for non-protected outdoor

installation.

Mounting on the Wall Plate

Mounting on other surfaces

Make sure that the wall plate is sufficiently

securely fixed to the installation surface.

Hang the luminaire onto the M10 x 40

screws and tighten them with a torque of

44 Nm. The threaded inserts in the wall

plate are self locking. Insert the cable

through the cable gland into the luminaire

and then proceed with the electrical

connection as mentioned above.

Make sure that the installation surface is

sufficiently stable and strong. To attach the

luminaire, use at least 2 stainless steel M10

screws of hardness 70. Take adequate

precautions to prevent the screws from

loosening. Make electrical connection as

mentioned above.

The glass is toughened safety glass.

Ensure that the minimum spacing between

luminaire and illuminated surface is

observed.

The light fitting may be operated only if all

protective covers are in place.

Type

Weight

Projected area

8 271 3.1

9,0 kg

0,11 m

8 273 3.1

9,5 kg

0,11 m

2

2

Protection IP 65
Safety Class I

8 271 3.1
8 273 3.1

min 0,5 m

min 0,8 m

8 271 3.1

8 273 3.1

MOUNTING

INSTRUCTIONS

.

Stemmessiepener Weg 5

D-58675 Hemer

Reviews: