Fluxa A - with arm
Area floodlight for wall-
or pole mounting
Area floodlight for metal halide lamps
HIT-DE, HIT-DE-CE,
high pressure sodium lamps HST-DE
70 / 150 Watts, lampholder Rx7s.
MOUNTING INSTRUCTIONS
Light fitting is suitable for installation on
normal inflammable building materials.
Attention ! High Voltage !
Disconnect power supply before opening
light fitting or changing lamp.
Ensure that the correct size of pole is chosen;
if necessary consult the pole manufacturer.
Loosen screws in front frame. Lift frame and
glass and swing away from casing.
Depending on height of pole, take
a sufficiently long piece of cable
and insert it through the cable gland.
Strip the sheathing off the last 9 cm
of cable and slide the enclosed silicone
sleeves over the individual wires.
ATTENTION ! Do not insert more than 2 cm
of sheathed cable into luminaire housing.
Make the electrical connection.
Screw cable gland tight. Insert lamp, taking
care to use the correct lamp as mentioned
on the rating plate. If a high pressure sodium
lamp is to be used, make sure that only
lamps bearing the
- sign are used.
Connect the light fitting in compliance with
prevailing regulations in your country.
Swing front frame and glass back onto
casing and screw down evenly.
Hang the luminaire onto the M10 x 40
screws on the pole top fitter and tighten with
44 Nm torque. The threaded inserts in the
pole top fitter are self locking.
Push cable through hole in pole and
connect to connection box in base of pole.
Mounting on pole top fitter
Luminaire for non-protected outdoor
installation.
Mounting on the Wall Plate
Mounting on other surfaces
Make sure that the wall plate is sufficiently
securely fixed to the installation surface.
Hang the luminaire onto the M10 x 40
screws and tighten them with a torque of
44 Nm. The threaded inserts in the wall
plate are self locking. Insert the cable
through the cable gland into the luminaire
and then proceed with the electrical
connection as mentioned above.
Make sure that the installation surface is
sufficiently stable and strong. To attach the
luminaire, use at least 2 stainless steel M10
screws of hardness 70. Take adequate
precautions to prevent the screws from
loosening. Make electrical connection as
mentioned above.
The glass is toughened safety glass.
Ensure that the minimum spacing between
luminaire and illuminated surface is
observed.
The light fitting may be operated only if all
protective covers are in place.
Type
Weight
Projected area
8 271 3.1
9,0 kg
0,11 m
8 273 3.1
9,5 kg
0,11 m
2
2
Protection IP 65
Safety Class I
8 271 3.1
8 273 3.1
min 0,5 m
min 0,8 m
8 271 3.1
8 273 3.1
MOUNTING
INSTRUCTIONS
.
Stemmessiepener Weg 5
D-58675 Hemer