Meyer Sound DS-2P Operating Instructions Manual Download Page 8

8

Rigging

The DS-2P weighs 221 lb (100 kg). The maximum recom-
mended load for a single cabinet with aircraft pan fittings
is 600 lb (273kg). This  working load is based on a 5:1 safety
factor. The DS-2P has six rigging brackets (three on top
and bottom). Each bracket is capable of supporting the
full working load of the cabinet.

There are four types of interchangeable rigging brackets,
each fastened by six Phillips screws:

• aircraft pan fittings (ring and stud)

3

/

8

”-16 nut plates

• M-10 x 1.5 metric nut plates

• blank plates (if no rigging brackets are requested)

NOTE: Units with nut plates are rated for the weight of
one cabinet only.

rigging brackets

three on top, three on bottom

Handles are for carrying only. 
Do not use them for rigging!

!

Rigging load ratings assume a straight tensile pull and
that the cabinet is in new condition with aircraft pan
fittings. If these conditions are not met, the load ratings
can be reduced significantly. Load ratings can also be
reduced by age, wear, and damage. It is important to
inspect the rigging hardware regularly and replace worn
or damaged components immediately.

The cabinet, exposed electronic circuitry, and drivers can
receive protective treatment that permits safe use in wet
conditions. Additionally, a rain hood can be fitted to
shield cables and electronics. Do not install a unit outdoors
without weather protection! 
Contact Meyer Sound for more
information.

NOTE: All Meyer Sound products must be used in accor-
dance with local, state, federal, and industry regulations.
It is the owner’s and/or user’s responsibility to evaluate
the reliability of any rigging method for their application.
Rigging should be done only by experienced professionals.

Measurement and System
Integration Tools

It is essential that even the most carefully assembled
sound systems be analyzed with precise measurement
tools. We recommend using the Meyer SIM® System II
Sound Analyzer 

and CP-10 Parametric Equalizer to

• assist the process of choosing and configuring

speakers;

• measure propagation delays between subsystems

to set the correct polarity and delay times;

• measure and equalize variations in frequency

response caused by the acoustical environment
and the placement and interaction of speakers.

Contact Meyer Sound for assistance with your application.

We recommend using the Meyer LD-1A Line Driver to
integrate different types of Meyer self-powered speakers
into a complete system. The LD-1A has two channels
equipped to control a full-range main system, and six
auxiliary channels for down-fill, front-fill, and delay
systems. The LD-1A maintains signal integrity for long
cable paths and provides the following useful functions:

• The  Lo Cut switch activates a high-pass filter

(160 Hz, –12 dB/oct, Q = 0.8) that performs a
crossover function for the Mid-Hi output.

• The DS-2 & Sub Crossover switch (channels 1 and

2 only) activates a crossover network optimized
for the DS-2P when used with the PSW-2 or 650-P.
With the switch in, frequencies below 80 Hz are
sent to the Sub output (for the 650-P), and above
80 Hz to the DS-2 output. When the subwoofer is
used without the DS-2P, (or the DS-2P is used
alone as a subwoofer) the switch should be out,
which sends a full-range signal to both the DS-2
and Sub outputs.

• The DS-2 

φ

 

and Sub 

φ 

switches (channels 1 and 2

only) toggle the polarity for the DS-2 and Sub
outputs.

• The Mid-HiDS-2, and Sub outputs  (channels 1

and 2 only) each have their own gain control and
mute switch.

POLARITY NOTE: 

The polarity for Meyer self-powered

speakers may be reversed using the input polarity switch
on the user panel. The LD-1A also allows polarity reversal
with the 

DS-2 

φ

 

and 

Sub 

φ

 

switches for speakers

connected to the DS-2 and Sub outputs. When making
polarity decisions in applications that include the LD-1A,
check the state of all polarity switches.

Summary of Contents for DS-2P

Page 1: ...Operating Instructions DS 2P Patents Pending Self Powered Mid bass Speaker Copyright 1997 Meyer Sound Laboratories Inc All rights reserved Part 05 035 005 01 Rev B...

Page 2: ...9600 58 FAX 49 2654 9600 59 Declaration of Conformity Contact Information Office of Quality Manager Berkeley California USA October 1 1995 1 0 kV Power Lines Shock 30 g 11 msec half sine on each of 6...

Page 3: ...Specifications 14 ATENCI N ACCESO INTERNO SOLO AUTORIZADO A PERSONAL T CNICO CALIFICADO ACHTUNG GEH USE NICHT FFNEN WARTUNG UND REPARATUR NUR DURCH ELEKTROFACHKR FTE ATTENTION ENTRETIEN ET REPARATION...

Page 4: ...er inlet and satisfies UL CSA and EC safety standards Voltage Requirements The DS 2P operates safely and without audio discon tinuity if the AC voltage stays within the ranges 85 134 V or 165 264 V at...

Page 5: ...a R t n e r r u C P 2 S D V 5 1 1 V 0 3 2 V 0 0 1 S M R s u o u n i t n o C x a M A 8 S M R A 4 S M R A 0 1 S M R S M R t s r u B x a M A 5 1 S M R A 8 S M R A 8 1 S M R t s r u B g n i r u D k a e P...

Page 6: ...certain that the source equipment can drive the total load impedance presented by the paralleled input circuit For example since the input impedance of a single DS 2P is 10 k cascading 20 DS 2Ps prod...

Page 7: ...uses a forced air cooling system with two fans to prevent the amplifiers from overheating The fans draw air in through ducts on the front of the cabinet over the heatsinks and out the rear of the cabi...

Page 8: ...ems be analyzed with precise measurement tools We recommend using the Meyer SIM System II Sound Analyzer and CP 10 Parametric Equalizer to assist the process of choosing and configuring speakers measu...

Page 9: ...6 can be used with identical connections for the other half The MSL 4 DS 2P and CQ arrays are flown the 650 Ps are on the floor The CH 1 Mid Hi and CH 3 outputs drive the inner three and outer two sp...

Page 10: ...ssipation in the driver regardless of the input signal level Therefore if all DS 2Ps in a system receiving the same audio signal exhibit TPL activity except one then that unit may have an open voice c...

Page 11: ...with reverse polarity cause acoustic cancellation Top driver is 180 out of phase The polarity is correct if the frequency response is 4 dB 50 160 Hz Cancellation greater than 6 dB in the same range i...

Page 12: ...face Speakers placed on the floor benefit from half space loading while flown speakers in free space without a nearby wall or ceiling do not In general subwoofers in half space generate twice the SPL...

Page 13: ...nur von ausgebildetem Kundenienstpersonal durchgef hrt werden Para reducir el riesgo de descarga el ctrica desconecte de la red el altoparlante antes de instalar el cable de se alizaci ndeinterfazdel...

Page 14: ...0P IEC 309 Twistlock male receptacle 85 134 V 165 264 V 50 Hz 60 Hz 115 V 8 A 230 V 4 A 100 V 10 A 115 V 15 A 230 V 8 A 100 V 18 A 115 V 22 Apk 230 V 11 Apk 100 V 25 Apk Inrush current 12A 115V 21 25...

Reviews: