Meyer Sound Amie-Sub Operating Instructions Manual Download Page 1

Keep these important operating instructions.

Check www.meyersound.com for updates.

OPERATING INSTRUCTIONS

ULTRA

Amie-Sub Compact Cinema Subwoofer 

Summary of Contents for Amie-Sub

Page 1: ...Keep these important operating instructions Check www meyersound com for updates OPERATING INSTRUCTIONS ULTRA Amie Sub Compact Cinema Subwoofer...

Page 2: ...be reproduced stored in a retrieval system or transmitted in any form or by any means electronic mechanical recording or otherwise without prior writ ten permission from Meyer Sound CAL Compass Go by...

Page 3: ...the replaceable fuse is the only user serviceable item When replacing the fuse only use the same type and the same value 15 Refer all other servicing to qualified service personnel Servicing is requi...

Page 4: ...ekter Sonneneinstrahlung fern und stellen Sie es nicht in der N he von w rmeabstrahlenden Ger ten z B Heizger t oder Herd auf Bei Ausstattung mit einem externen Sicherungshalter ist die austauschbare...

Page 5: ...onerlo a la luz solar directa No instale la unidad cerca de aparatos que emitan calor como un calefactor o una estufa Si est equipado con un portafusibles externo el fusible reemplazable es el nico el...

Page 6: ...AMIE SUB OPERATING INSTRUCTIONS vi...

Page 7: ...Current Requirements 13 Intelligent AC Power Supply 14 Electrical Safety Guidelines 14 Chapter 3 Amplification and Audio Connectors 17 Optional Integration Input Modules 18 TruPower Limiting 20 Amplif...

Page 8: ...AMIE SUB OPERATING INSTRUCTIONS viii...

Page 9: ...quency response down to 22 Hz with easy integration in multichannel configurations In addition due its performance and versatility the Amie Sub is equally suited to complement other Meyer Sound loudsp...

Page 10: ...e features industry standard multi pin DB 25 and can be used in 5 1 or 7 1 configurations with third party high quality 8 channel DB 25 to XLR cables The integration modules feature bass management pr...

Page 11: ...damage to the input and output stages of the system s electronic components 120 V AC 3 Phase Wye System Single Line Line Neutral Earth Ground Figure 4 illustrates a basic 120 V AC 3 phase Wye distribu...

Page 12: ...power cable 15 A Consider the total current draw for all loudspeakers on the circuit including the first loud speaker Table 1 AC Loop Output Gray The gray AC Loop Output connector allows multiple Amie...

Page 13: ...not cause the loud speaker s amplifier to cycle on and off or cause dam age to the power supply CURRENT REQUIREMENTS Current draw for loudspeakers is dynamic and fluctuates as operating levels change...

Page 14: ...ation temporarily during low voltage periods Powering on Amie Sub When powering on Amie Sub the following startup events take place over several seconds 1 Audio output is muted 2 Voltage is detected a...

Page 15: ...the circuit including the first loudspeaker Make sure the AC power cable for the loudspeaker has the appropriate power plug on the other end for the area in which you will operate the loudspeaker In...

Page 16: ...AMIE SUB OPERATING INSTRUCTIONS 16...

Page 17: ...dio source The Loop output connector uses the same wiring scheme as the Input connector see Audio Input XLR 3 Pin Female on this page For applications that require multiple Amie Sub connect the Loop o...

Page 18: ...LFE Bass Management For the LFE output there are three controls on the user panel that affect operation see Figure 13 and Figure 14 LFE switch the user can selectively add 10 dB of gain by setting thi...

Page 19: ...Ch or 7 1 DB 25 7 Ch Inputs 2 Ch or 7 Ch 2 Ch or 7 Ch Sum Sum Ch 1 Ch 7 10 dB LFE Gain Switch Base Management Bypass Amie Sub Power Amp On Level 6 dB 0 dB Passive Path Loop Out Balanced Receivers Bala...

Page 20: ...t summation may be boosted or attenuated by the 6 dB LFE Bass Management dial NOTE The option to boost the signal by 10 dB is provided for playback of recorded audio in situations where the LFE channe...

Page 21: ...ING SYSTEM CAUTION The Amie Sub loudspeaker is convection cooled The amplifier s heat sink provides natural convection cooling from the air flowing near its fins CAUTION The Amie Sub heat sink can rea...

Page 22: ...AMIE SUB OPERATING INSTRUCTIONS 22...

Page 23: ...ch mounting hardware to the building s structural components studs or joists and not just to the wall surface Verify that the building s structure and the anchors used for the installation will safely...

Page 24: ...h 16 mounting points on both sides of the cabinet The kit includes two 3 8 inch screws washers for attaching the MUB Amie Sub to the loudspeaker BLACK CLOTH GRILLE FRAME The optional grille frame with...

Page 25: ...on of the environment in which they operate including air temperature pressure humidity and the location of prediction surfaces Importing both CAD DXF and Sketchup SKP files containing detailed venue...

Page 26: ...ludes custom designed settings for each family of speakers as well as to integrate families together For example the Product Integration feature matches the phase characteristics between Meyer speaker...

Page 27: ...most common input spectrum and to verify there is still headroom over pink noise COVERAGE 360 single unit varies with number of units and configuration TRANSDUCERS Low Frequency One 15 inch cone driv...

Page 28: ...er cabling must be of sufficient gauge so that under burst current rms conditions cable transmission losses do not cause the loudspeaker s voltage to drop below the specified operating range Maximum I...

Page 29: ...PPENDIX A AMIE SUB SPECIFICATIONS 29 AMIE SUB LOUDSPEAKER DIMENSIONS Figure 21 Amie Sub Loudspeaker Dimensions 17 50 in 444 5 mm 24 00 in 610 mm 8 52 in 216 mm 19 00 in 483 mm 9 75 in 248 mm M8 thread...

Page 30: ...AMIE SUB OPERATING INSTRUCTIONS 30...

Page 31: ......

Page 32: ...Sound Laboratories Inc 2832 San Pablo Avenue Berkeley CA 94702 www meyersound com T 1 510 486 1166 2020 Meyer Sound Laboratories Inc All rights reserved Amie Sub Operating Instructions PN 05 251 005...

Reviews: