Metso LCP9H Series Installation Maintenance And Operating Instructions Download Page 12

Metso Flow Control Inc. 

Europe, 

 Vanha Porvoontie 229, P.O. Box 304, FI-01301 Vantaa, Finland. Tel. +358 20 483 150. Fax +358 20 483 151

North America,

  44 Bowditch Drive, P.O. Box 8044, Shrewsbury, M A  01545, USA. Tel. +1 508 852 0200. Fax +1 508 852 8172

South America, Av

. Independéncia, 2500-Iporanga, 18087-101, Sorocaba-São Paulo, Brazil. Tel. +55 15 2102 9700. Fax +55 15 2102 9748 

Asia Pacific,

 238B Thomson Road, #17-01 Novena Square Tower B, Singapore 307685. Tel. +65 6511 1011. Fax +65 6250 0830

China, 

11/F, China Youth Plaza, No.19 North Rd of East 3rd Ring Rd, Chaoyang District, Beijing 100020, China. Tel. +86 10 6566 6600. Fax +86 10 6566 2583

Middle East, 

Roundabout 8, Unit AB-07, P.O. Box 17175, Jebel Ali Freezone, Dubai, United Arab Emirates. Tel. +971 4 883 6974. Fax +971 4 883 6836

www.metso.com/valves

12

7 LCP9H 70 en Liwa

11

TYPE CODING

OPTIONAL DEVICE FOR VG9000H

LCP9H_

Externally powered Local Control Panel (LCP)

Versions for Ex i/e: 

LCP9H, LCP9HW.

Stainless steel 316L, IP66.

Versions for Ex d: L

CP9HE, LCP9HEW

.

Anodized aluminum, IP66

All versions include LEDs, Manual Reset and PST buttons.
Trip button removed in W versions. Buttons are lockable in 
all versions.
Power consumption 400 mW. Power supply 11-30 V DC, 
50 mA

ATEX and IECEx certifications:

LCP9H, LCP9HW: 

 

II 2 G Ex ia IIC T6...T4 Gb
Temperature range: T4; -20° to +85 °C, T5; -20° to +80 °C,
T6; -20° to +65 °C.
II 3 G Ex ic IIC T6...T4 Gc
Temperature range: T4; -20° to +85 °C, T5; -20° to +80 °C, 
T6; -20° to +85 °C.
II 2G Ex eb mb [ib] IIC T6...T4 Gb
Temperature range: T4; -20° to +65 °C, T5; < +65 °C,
T6; < +60 °C.

LCP9HE, LCP9HEW:

II 2 GD
Ex d IIB+H

2

 T6 Gb

Ex tb IIIC T85°C Db IP66
Ta -20° to +65 °C.

INMETRO certifications:

LCP9H, LCP9HW: 

Ex ia IIC T6...T4 Gb
Tamb: T6; -20 ... +50 °C, T5; -20 ... +65 °C, T4; -20 ... +65 °C
Ex ic IIC T6...T4 Gc
Tamb: T6; -20 ... +60 °C, T5; -20 ... +65 °C, T4; -20 ... +65 °C

LCP9HE, LCP9HEW: 

Ex d IIB+H

2

 T6 Gb

Ex tb IIIC T85°C Db IP65
Ta -20° to +65 °C

NOTE:

 7. sign "L2"  in VG9000H type coding needs to be 

selected for additional conduit entries and terminal strip.

NOTE:

 See manual 7VG9H70en for further VG9000H details.

OPTIONAL DEVICE FOR VG9000H

LCP9H_L

LOOP POWERED Local Control Panel (LCP)

Versions for Ex i/e: 

LCP9HL, LCP9HWL.

Stainless steel 316L, IP66.

Versions for Ex d: 

LCP9HEL, LCP9HEWL.

Anodized aluminum, IP66.

All versions include LEDs, Manual Reset and PST buttons. 
Trip button removed in W versions. Buttons are lockable in 
all versions.
Power taken from VG input signal (min 8mA).

ATEX and IECEx certifications:

LCP9HL, LCP9HWL

II 2 G Ex ia IIC T6...T4 Gb
Temperature range: T4; -20° to +65 °C, T5; -20° to +65 °C, 
T6; -20° to +50 °C.
II 3 G Ex ic IIC T6...T4 Gc
Temperature range: T4; -20° to +65 °C, T5; -20° to +65 °C, 
T6; -20° to +60 °C.
II 2G Ex eb mb [ib] IIC T6...T4 Gb
Temperature range: T4; -20° to +65 °C, T5; -20° to +63 °C,
T6; -20° to +48 °C.

LCP9EHL, LCP9HEWL:

II 2GD
Ex d IIB+H2 T6 Gb
Ex tb IIIC T85°C Db IP66
Ta -20°C to +65°C

NOTE:

 7. sign "L3" needs to be selected in VG9000H type

coding for additional conduit entries and terminal strip.

NOTE:

 Minimum input signal for VG9000H is 8 mA.

Summary of Contents for LCP9H Series

Page 1: ...Local Control Panels forVG9000H LCP9H Series Installation Maintenance and Operating Instructions NOTE Special version for Liwa project 7 LCP9H 70 en Liwa 5 2018 ...

Page 2: ...ademarks are property of their respective owners Table of Contents 1 LCP9H Local Control Panels for VG9000H 3 1 1 General 3 1 2 Technical description 3 1 3 System architecture 3 1 4 Markings 4 1 5 Technical specifications 4 1 6 Recycling and disposal 6 1 7 Safety precautions 6 2 TRANSPORTATION RECEPTION AND STORAGE 6 3 MOUNTING 7 3 1 Electrical connections 7 4 LCP9H LAYOUT AND FUNCTIONALITY 7 4 1 ...

Page 3: ...g position when the trip initiators are normal manual reset functionality see 4 1 2 for details There is also the option for functional testing PST of the emer gency isolation valve test functionality see 4 1 3 for details Trip functionality is removed in the W versions of the LCP9H See the details of different types of LCP9H in the type cod ing at the end of this document LCP9H has also indicator...

Page 4: ...al connection max 2 5 mm2 LCP9H 2 pcs conduit entry dia 21 mm cable glands for cable with with ext dia 8 12mmincluded LCP9HE 2 pcs conduit entry M20x1 5 Power consumption 400 mW Power supply Externally powered versions 11 24 V DC 50 mA Short circuit protected Maximum distance 1200 m Loop powered versions power taken from VG9000H input signal minimum 8 mA Interface values for externally powered ver...

Page 5: ...mH Co 3 6 μF Ex ic IIC T6 T4 Gc Input values for the power supply Ui 28 V Ii 120 mA Pi 1 W Li 313 μH Ci 27 5 nF Output values for the communication interface Tx Uo 8 3 V Io 5 8 mA Po 12 mW Lo 50 mH Co 3 6 μF Rx Uo 6 5 V Io 1 8 mA Po 3 mW Lo 50 mH Co 152 μF ATEX and IECEx approvals are valid under these conditions Compatible isolators for the power supply not loop pow ered models MTL 5021 P F KFD0 ...

Page 6: ...ailable from the manufacturer The Local Control Panel may also be returned to the manufac turer for recycling and disposal There will be a charge for this 1 7 Safety precautions 2 TRANSPORTATION RECEPTION AND STORAGE The Local Control Panel is a sophisticated instrument han dle it with care Check the Local Control Panel for any damage that may have occurred during transportation Store the Local Co...

Page 7: ... are as follows Ready To Open amber PST amber Open green Closed red FAULT white NOTE The tightening torque for the cover screws of LCP9HE_ versions is 16 Nm NOTE The enclosure of the LCP9H meets the IP66 protection class according to EN 60529 in any position when the cable entries are plugged according to IP66 Based on good mounting practice the recommended mounting position is with electrical con...

Page 8: ...est of the emergency isolation valve The stroke size of the test can be set via HART DTM EDD or from the LUI Local User Interface of the VG9000H See VG9000H manual 7VG970en for details The manual test via LCP9H uses the same stroke size than manual PST programmed into VG9000H itself To start the PST test press and release the PST button and the PST LED will be illuminated To stop the ongoing manua...

Page 9: ...be turned on 6 TROUBLE SHOOTING If the LCP9H does not work check the following Check the LCP parameter in the VG9000H The LCP parameter in the VG9000H needs to be ena bled Go to the parameters menu in the VG9000H LUI and check that LCP is enabled For details see the VG9000H IMO This can also be checked in Assembly Related view in the VG9000H DTM Check that LCP is selected in the External Devices p...

Page 10: ...ST READY TO OPEN CLOSE FAULT PST CLOSED OPEN Note This button is only available in LCP9H or LCP9HL LCP9HW or LCP9HWL does not have this button Note This button is only available in LCP9HE and LCP9HEL LCP9HEW or LCP9HEWL does not have this button Note The tightening torque for the cover screws is 16 Nm ...

Page 11: ...an Com munity Applicable directives EMC 2004 108 EC Electrical ATEX 2014 34 EU Approved and Ex marked types ATEX Notified Bodies for EC Type Examination Certificate SIRA Notified body number 0518 Sira Certification Service Rake Lane Eccleston Chester CH4 9JN England VTT Notified body number 0537 VTT Expert Services Otakaari 7B Espoo P O Box 1000 FI 02044 VTT Finland ATEX Notified Body for Quality ...

Page 12: ...C T6 T4 Gc Temperature range T4 20 to 85 C T5 20 to 80 C T6 20 to 85 C II 2G Ex eb mb ib IIC T6 T4 Gb Temperature range T4 20 to 65 C T5 65 C T6 60 C LCP9HE LCP9HEW II 2 GD Ex d IIB H2 T6 Gb Ex tb IIIC T85 C Db IP66 Ta 20 to 65 C INMETRO certifications LCP9H LCP9HW Ex ia IIC T6 T4 Gb Tamb T6 20 50 C T5 20 65 C T4 20 65 C Ex ic IIC T6 T4 Gc Tamb T6 20 60 C T5 20 65 C T4 20 65 C LCP9HE LCP9HEW Ex d ...

Reviews: