DL7, DL7L
44
Fig. 8.1 An example
view of the ‘USB’ window.
The duration of the process is signalled by the blue diode on the front panel. After correct
storage of the date, a suitable message is displayed.
To erase a selected archive file, first select the required file from the list and then click
the
Delete selected
button.
!
Removing the USB flash memory before the writing process is complete
may result in damaging of the recorded files.
There is also a possibility:
saving settings on a USB flash memory (select the option
Save on USB
)
reading settings from a USB flash memory (select relevant file from the list and
then choose the option
Read from USB
).
If new settings file from the flash memory is read, the device will automatically reboot.
8.5 Factory settings
To restore the device to the factory settings, first login as the Administrator.
!
Before selecting the factory settings option, it is recommended to save the
previous settings on the USB flash memory. Otherwise, the settings will be
lost. Files in the archive will not be deleted.
!
The administrator password will not be changed. The user's password will be
restored to default.
In the next step, select the
button from menu bar and then the
icon. Select the
Service
tab and then
Restore Factory Settings
button. The device will automatically reboot
with factory settings in the used language (if the language change has been saved).
Previous settings will be lost, in particular I/O settings
– all inputs / outputs will be turned
off. Configure the settings of the device starting from I/O stetting, in the order described in
section
Recommended order for configuration of the device