background image

 

 

46 

L

IMITED 

W

ARRANTY 

 

 

The MS3580 Quantum

T

 scanners are manufactured by Metrologic at its Blackwood, New Jersey, 

U.S.A. facility. The MS3580 Quantum

T

 scanners have a three (3) year limited warranty from the date of 

manufacture.  Metrologic warrants and represents that all MS3580 Quantum

T

 scanners are free of all 

defects in material, workmanship and design, and have been produced and labeled in compliance with 
all applicable U.S. Federal, state and local laws, regulations and ordinances pertaining to their 
production and labeling. 
 
This warranty is limited to repair, replacement of product or refund of product price at the sole discretion 
of Metrologic.  Faulty equipment must be returned to one of the following Metrologic repair facilities: 
Blackwood, New Jersey, USA; Madrid, Spain; or Suzhou, China.  To do this, contact the appropriate 
Metrologic Customer Service/Repair Department to obtain a Returned Material Authorization (RMA) 
number.  
 

In the event that it is determined the equipment failure is covered under this warranty, Metrologic 
shall, at its sole option, repair the Product or replace the Product with a functionally equivalent unit 
and return such repaired or replaced Product without charge for service or return freight, whether 
distributor, dealer/reseller, or retail consumer, or refund an amount equal to the original purchase 
price.   
 
This limited warranty does not extend to any Product which, in the sole judgment of Metrologic, 
has been subjected to abuse, misuse, neglect, improper installation, or accident, nor any damage 
due to use or misuse produced from integration of the Product into any mechanical, electrical or 
computer system. The warranty is void if the case of Product is opened by anyone other than 
Metrologic’s repair department or authorized repair centers. 
 
THIS LIMITED WARRANTY, EXCEPT AS TO TITLE, IS IN LIEU OF ALL OTHER WARRANTIES 
OR GUARANTEES, EITHER EXPRESS OR IMPLIED, AND SPECIFICALLY EXCLUDES, 
WITHOUT LIMITATION, WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A 
PARTICULAR PURPOSE UNDER THE UNIFORM COMMERCIAL CODE, OR ARISING OUT OF 
CUSTOM OR CONDUCT.  THE RIGHTS AND REMEDIES PROVIDED HEREIN ARE 
EXCLUSIVE AND IN LIEU OF ANY OTHER RIGHTS OR REMEDIES.  IN NO EVENT SHALL 
METROLOGIC BE LIABLE FOR ANY INDIRECT OR CONSEQUENTIAL DAMAGES, 
INCIDENTAL DAMAGES, DAMAGES TO PERSON OR PROPERTY, OR EFFECT ON 
BUSINESS OR PROPERTY, OR OTHER DAMAGES OR EXPENSES DUE DIRECTLY OR 
INDIRECTLY TO THE PRODUCT, EXCEPT AS STATED IN THIS WARRANTY.  IN NO EVENT 
SHALL ANY LIABILITY OF METROLOGIC EXCEED THE ACTUAL AMOUNT PAID TO 
METROLOGIC FOR THE PRODUCT.  METROLOGIC RESERVES THE RIGHT TO MAKE ANY 
CHANGES TO THE PRODUCT DESCRIBED HEREIN. 

 

C

ORPORATE 

H

EADQUARTERS

N

ORTH 

A

MERICA

 

 

 

M

ETROLOGIC 

E

UROPEAN 

R

EPAIR 

C

ENTER

(MERC) 

Metrologic Instruments, Inc. 

 

Metrologic Eria Ibérica, SL 

90 Coles Rd. 

  C/Alfonso Gomez, 38-40, 1D 

Blackwood, NJ 08012-4683 

  28037 Madrid 

Customer Service Department 

  Tel: +34 913 751 249 

Tel: 1-800-ID-METRO 

  Fax: +34 913 270 437 

Fax: 856-228-6673 

   

Email: [email protected] 

   

 

   

 

   

MTLG

 

A

UTO 

ID

 

I

NSTRUMENTS 

(S

HANGHAI

)

 

C

O

.,

 

L

TD

 

   

Suzhou Sales Office 

   

BLK A, Room#  03/03-04 

   

No.5 Xinghan Street, Xinsu Industrial Square 

   

China-Singapore Suahou Industrial Park, Suzhou, PRC     
Tel:  86-512-67622550 

   

Fax:  86-512-67622560 

   

Email:  [email protected] 

   

 

Summary of Contents for QuantumT MS3580

Page 1: ...METROLOGIC INSTRUMENTS INC MS3580 QuantumT Installation and User s Guide...

Page 2: ...reproduced transmitted or stored in any form or by any means without prior written consent except by reviewer who may quote brief passages in a review or provided for in the Copyright Act of 1976 Prod...

Page 3: ...ation 8 IBM 46xx or OCIA 9 Keyboard Wedge 10 Stand Alone Keyboard Wedge 11 Full Speed or Low Speed USB Integrated 12 Scanner Operation Configurable Primary and Secondary Scan Pattern Modes 13 Configur...

Page 4: ...Default Settings Communication Parameters 34 Upgrading the Flash ROM Firmware 39 Scanner and Cable Terminations 40 Scanner Pinout Connections 40 Cable Connector Configurations Host End 42 Laser and P...

Page 5: ...Reading Custom Configurable Scan Pattern User Replaceable Single Cable Interface to Host PowerLink Compatible Decoding of All Standard 1D RSS 14 RSS Limited and Expanded RSS Bar Codes 7 Beeper Tones...

Page 6: ...Canada 45 45591 220V 240V Continental European 45 45592 220V 240V United Kingdom 46 46803 220V 240V Australia 46 46983 220V 240V China 54 54000x 3 RS232 PowerLink Cable with Built in Power Jack 2 1 m...

Page 7: ...B Full Speed Cable Locking Plus Power Type A 5 m 17 ft straight cord short strain relief This cable is for use with full speed USB 40 interface only 54 54235x N 3 USB Low Speed Communication Cable Typ...

Page 8: ...t 4 Speaker 5 Blue and White LED Indicators 6 Button 7 Protective Boot and Stand Connection Never remove the protective boot from the MS3580 Removing the protective boot will expose electrical compone...

Page 9: ...tallic pin into the small pin hole 4 You will hear a faint click when the cable lock is released Pull gently on the strain relief of the PowerLink cable to remove it from the scanner Figure 3 Maintena...

Page 10: ...on Qty Item Description Qty 1 MS3580 QuantumT 1 6 Flexible Shaft 1 2 Pivot Cylinder 1 7 Base Plate Cover 1 3 Bearing Plate 1 8 8 x 1 00 Wood Screw 4 4 Pole Mount Adapter 1 9 Base Plate 1 5 Flexible Sh...

Page 11: ...7 INTRODUCTION Mounting Specifications and Stand Assembly Optional Flex Stand Figure 6 Mounting Hole Detail for the Flex Stand Base Plate Optional Figure 7 Assembling the Optional Flex Stand...

Page 12: ...rt of the PC does not guarantee that scanned information will appear at the PC A software driver and correct configuration setting are also required for proper communication to occur The MS3580 104 le...

Page 13: ...canner into the serial port of the PC does not guarantee that scanned information will appear at the PC A software driver and correct configuration setting are also required for proper communication t...

Page 14: ...urn on the host device When the scanner first receives power the blue LED will turn on the scanner will simultaneously emit a beep and flash the white LED Powering the MS3580 directly from the host de...

Page 15: ...will turn on the scanner will simultaneously emit a beep and flash the white LED Powering the MS3580 directly from the host device can sometimes cause interference with the operation of the scanner o...

Page 16: ...580 38 for USB Serial Emulation Mode please refer to Section P Low Speed USB in the MetroSelect Configuration Guide MLPN 00 02407 Plugging the scanner into the USB port of the PC does not guarantee th...

Page 17: ...t Each pattern mode can be configured to use one of three scan patterns listed below Please refer to the MetroSelect Configuration Guide for information on changing the default scan pattern settings a...

Page 18: ...set to single line menu reading with a 5 second button click timeout configured 1 The primary scan pattern is active when the scanner starts 2 To activate the secondary scan pattern press and release...

Page 19: ...tern has been set to single line menu reading with a 5 second button click timeout configured 1 The primary scan pattern is active when the scanner starts 2 To activate the secondary scan pattern pres...

Page 20: ...ing and the secondary pattern has been set to single line menu reading with a 5 second button click timeout configured 1 The primary scan pattern is active when the scanner starts 2 To activate the se...

Page 21: ...igurable Button Functions 5 To scan and transmit additional bar codes repeat steps 2 through 4 6 The primary scan pattern will automatically reactivate after the button is released and no bar code is...

Page 22: ...5 second button click timeout configured 1 The primary scan pattern is active when the scanner starts 2 To activate the secondary scan pattern press and hold the button 3 To scan and transmit the bar...

Page 23: ...e light does not flash then the bar code has not been successfully read Razzberry Tone This is a failure indicator Refer to Failure Mode Indicators on page 21 Three Beeps during operation When placing...

Page 24: ...he scanner successfully reads a bar code the white LED will flash and the scanner will beep once If the white LED does not flash or the scanner does not beep once then the bar code has not been succes...

Page 25: ...experienced a motor failure Return the unit to an authorized service center for repair Continuous Razzberry Tone with Both LEDs Off If upon power up the scanner emits a continuous razzberry tone then...

Page 26: ...h of Field Specifications Normal Scan Zone Specifications are based on a 0 33 mm 13 mil bar code Figure 14 MS3580 Normal Depth of Field All specifications are subject to change without notice MS3580 s...

Page 27: ...of Field Specifications Reduced Scan Zone Specifications are based on a 0 33 mm 13 mil bar code Figure 15 MS3580 Reduced Depth of Field All specifications are subject to change without notice MS3580...

Page 28: ...Bar Code Element Width Normal Scan Zone MINIMUM BAR CODE ELEMENT WIDTH A B C D E F mm 13 15 19 25 33 66 mils 5 2 5 7 7 5 10 13 26 Figure 16 Normal Scan Zone by Bar Code Element Width All specification...

Page 29: ...ar Code Element Width Reduced Scan Zone MINIMUM BAR CODE ELEMENT WIDTH A B C D E F mm 13 15 19 25 33 66 mils 5 2 5 7 7 5 10 13 26 Figure 17 Reduced Scan Zone by Bar Code Element Width All specificatio...

Page 30: ...will cause the scanner to exit power save mode The laser will automatically turn back on preparing the scanner for bar code recognition decoding and transmission Normal Figure 18 Normal IR Activation...

Page 31: ...are multiple scans upon presentation of code The same symbol timeout is set too short Adjust the same symbol timeout for a longer time increment The beeper is disabled Enable the beeper The unit powe...

Page 32: ...atches the format required by the host Make sure that the scanner is connected to the proper host port The print quality of the bar code is suspect The aspect ratio of the bar code is out of tolerance...

Page 33: ...VLD failure Contact a Metrologic service representative During power up the unit razzes twice and both LEDs flash There is a scanner motor failure Contact a Metrologic service representative RS232 Onl...

Page 34: ...onfigured for the appropriate mode Make sure that the proper PC type ie AT PS2 or XT is selected Verify correct country code and data formatting are selected The unit scans but the data is not correct...

Page 35: ...Lines 4 Motor Speed 5000 RPM Min Bar Width 0 127 mm 5 0 mil Decode Capability All standard 1 D bar codes including RSS 14 RSS Expanded and RSS 14 Limited System Interfaces RS232 Keyboard Wedge Stand...

Page 36: ...cal at 5VDC DC Transformers Class II 5 2VDC 650 mA Laser Class 1 IEC 60825 1 1993 A1 1997 A2 2001 EN 60825 1 1994 A11 1996 A2 2001 EMC FCC ICES 003 EN 55022 Class A Environmental Operating Temperature...

Page 37: ...ge Interface is designed to be used for keyboard emulation only Many RS232 programmable functions e g formatting available in other Metrologic scanners are also available as keyboard wedge functions T...

Page 38: ...es not support every parameter If the interface supports a parameter listed in the charts on the following pages a check mark will appear PARAMETER DEFAULT OCIA USB RS232 OR RS232 TTL LIGHT PEN IBM 46...

Page 39: ...High as Scanned Spaces High as Scanned DTS SIEMENS DTS NIXDORF NCR F NCR S Poll Light Pen Source Beeper Tone Normal Beep Transmit Sequence Before Transmit Communication Timeout None Razzberry Tone on...

Page 40: ...ransmit Lead Zero on UPC E Convert EAN 8 to EAN 13 Transmit UPC A Number System Transmit UPC A Manufacturer ID Transmit UPC A Item ID Transmit Codabar Start Stop Characters CLSI Editing Enable Transmi...

Page 41: ...TX Prefix ETX Suffix Carriage Return Line Feed disabled by default in KBW Tab Prefix Tab Suffix DE Disable Command FL Laser Enable Command DTR Handshaking Support RTS CTS Handshaking Character RTS CTS...

Page 42: ...Programmable in 100msec steps MAX 800 msec Coupon Code 128 as code 39 as code 39 Programmable Code Lengths 7 avail Programmable Prefix Characters 10 avail Programmable Suffix Characters 10 avail Pref...

Page 43: ...tegrated full speed USB 40 and RS232 TTL Laser Emulation 104 units can be upgraded To upgrade all units a power supply and a PowerLink cable MLPN 54 54014 are required RS232 units can be upgraded usin...

Page 44: ...round 2 RS232 Transmit Output 2 RS232 Transmit Output 3 RS232 Receive Input 3 RS232 Receive Input 4 PC Data 4 RTS Output 5 PC Clock 5 CTS Input 6 KB Clock 6 DTR Input LTPN Source 7 PC 5V 7 Reserved 8...

Page 45: ...6 DTR Input 6 Clock In 7 IBM B Transmit 7 Clock Out 8 IBM A Receive 8 Clock in Return Clock out Rtrn 9 5VDC 9 5VDC 10 Shield Ground 10 Shield Ground MS3580 104 RS232 TTL Laser Emulation Pin Function...

Page 46: ...nd 6 Light Pen Data 7 CTS Input 8 RTS Output 9 5VDC USB Power Communication Cable MLPN 54 54213x N 3 54 54214x N 3 or 54 54235x N 3 Pin Function 1 PC 5V V_USB 2 D 3 D 4 Ground Shield Shield Stand Alon...

Page 47: ...cable with a 5 pin DIN male connector on one end and a 6 pin mini DIN female connector on the other According to the termination required connect the appropriate end of the adapter cable to the Power...

Page 48: ...me le scanner ou le laser Ne regardez jamais directement le rayon laser m me si vous croyez que le scanner est inactif N ouvrez jamais le scanner pour regarder dans l appareil Ce faisant vous vous ex...

Page 49: ...ce may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Notice This Class A digital apparatus complies w...

Page 50: ...nor any damage due to use or misuse produced from integration of the Product into any mechanical electrical or computer system The warranty is void if the case of Product is opened by anyone other th...

Page 51: ...ht or sublicense is granted either expressly or by implication estoppel or otherwise under any METROLOGIC or third party intellectual property rights whether or not such third party rights are license...

Page 52: ...ult Settings 13 14 33 34 38 Depth of Field Normal 22 24 31 38 Reduced 23 24 25 31 38 F Failure Modes 21 FCC 45 Firmware 39 Flash ROM 1 39 H Host 27 30 I IBM 9 34 38 Indicator Audible 4 13 19 21 27 30...

Page 53: ...RMA 46 ROM 29 RS232 8 29 30 34 38 RS232 TTL 8 33 S Scan Lines 31 Scan Pattern 1 31 Horizontal Raster 13 Omnidirectional 13 18 Primary 13 18 Secondary 13 18 Single Line 13 18 Scan Speed 31 SELV 8 12 Si...

Page 54: ...48 63 78 78 Email info sg metrologic com Fax 33 0 1 48 63 24 94 Email info fr metrologic com China MTLG Auto ID Instruments Shanghai Co Ltd Spain Madrid Tel 86 2158692780 Fax 86 21 58692782 Metrologi...

Page 55: ......

Page 56: ...June 2005 Printed in the USA 0 0 0 5 0 9 0 B...

Reviews: