Setting Up the Scanner

Page 6

MDE-4631 Metrologic® MS7120 Bar Code Scanner Setup · January 2007 

Figure 1: MS7120 Scanner to Profit Point D-Box Connections

Q12651-19 
(MS7120) Scanner

POS D-Box 
Power Supply

To Scanner Port

POS D-Box

Phone Jack 
Connector

Metrologic-supplied 
Cable

POS D-Box 
AC Plug

Note: The power transformer connection on the node in the cable is to be left open.

Performing the Verification Sequence

While in POS operations, scan an item. The scanner should beep when the item is scanned.

• If the correct item description appears on the screen, it indicates that the scanner is 

programmed correctly.

• If the message “# not on file” appears and the number shown on the screen matches the 

number under the scanned bar code, it indicates that the scanner is functioning correctly, 
but the bar code cannot be identified. The display may not show the first or the last digit 
printed on the item. Press 

CLEAR MENU

 to cancel the item entry.

• If the screen does nothing or displays the messages “Data Error on Scanner Port” or “Item 

Entry Error”, repeat the scan. If the same message appears, it indicates that the scanner 
may be programmed incorrectly. Proceed to 

“Programming a Sequence” on page 7

.

Note: The first time the scanner is turned on, the first scan may produce the error message 

“Data Error on Scanner Port” even if the scanner is programmed correctly.

Summary of Contents for MS7120 Orbit

Page 1: ...p Datalogic DLL2020 Bar Code Scanner Used on Profit Point Terminal for Datalogic DLL2020 scanners Refer to MDE 4354 Setting Up Metrologic MS6720 Bar Code Scanner for Metrologic MS6720 scanners IMPORTA...

Page 2: ...MS7120 Bar Code Scanner Setup January 2007 Warranty For information on warranty refer to MDE 4255 Gasboy s Warranty Policy Statement If you have any warranty related questions contact Gasboy s Warrant...

Page 3: ...work Follow the Regulations There is applicable information in NFPA 30A Automotive and Marine Service Code NFPA 70 National Electrical Code NEC OSHA regulations and federal state and local codes whic...

Page 4: ...nds after handling equipment Do not place any equipment in mouth IMPORTANT Oxygen may be needed at scene if gasoline has been ingested or inhaled Seek medical advice immediately Emergency First Aid In...

Page 5: ...e of the other parts in the shipping box including the scanner power transformer will be used with this installation 4 Insert the phone jack end of the scanner cable into the phone jack connector on t...

Page 6: ...the scanner is programmed correctly If the message not on file appears and the number shown on the screen matches the number under the scanned bar code it indicates that the scanner is functioning cor...

Page 7: ...at corresponds to the hard copy page in 00 02407 Metrologic Instruments Inc MetroSelect Configuration Guide included with the scanner If the bar code cannot be read from Figure 2 on page 8 through Fig...

Page 8: ...le RS 232 Mode Note Refer to page G1 in the 00 02407 Metrologic Instruments Inc MetroSelect Configuration Guide if necessary Figure 3 Space Parity CAUTION Use only for Profit Point PLUS systems Note R...

Page 9: ...d DOS Profit Point systems CAUTION Note Refer to page G2 in the 00 02407 Metrologic Instruments Inc MetroSelect Configuration Guide if necessary Figure 5 Set 9600 Baud Rate Use only for Profit Point P...

Page 10: ...nt and DOS Profit Point systems CAUTION Note Refer to page G4 in the 00 02407 Metrologic Instruments Inc MetroSelect Configuration Guide if necessary Figure 7 Set to 7 Data Bits Use only for Profit Po...

Page 11: ...S Profit Point systems CAUTION Note Refer to page G5 in the 00 02407 Metrologic Instruments Inc MetroSelect Configuration Guide if necessary Figure 9 Set to 1 Stop Bit Use only for NT Profit Point and...

Page 12: ...haking Note Refer to page G6 in the 00 02407 Metrologic Instruments Inc MetroSelect Configuration Guide if necessary Figure 11 Disable XON XOFF Handshaking Use only for Profit Point PLUS systems CAUTI...

Page 13: ...fit Point systems CAUTION Note Refer to page E14 in the 00 02407 Metrologic Instruments Inc MetroSelect Configuration Guide if necessary Figure 13 Expand UPC E to 12 Digits Use only for NT Profit Poin...

Page 14: ...West Friendly Avenue Post Office Box 22087 Greensboro North Carolina 27420 Phone 1 800 444 5529 http www gasboy com Printed in the U S A MDE 4631 Metrologic MS7120 Bar Code Scanner Setup January 2007...

Reviews: