![Metrologic IS3480 QuantumE Installation And User Manual Download Page 35](http://html1.mh-extra.com/html/metrologic/is3480-quantume/is3480-quantume_installation-and-user-manual_1779735035.webp)
31
D
ESIGN
S
PECIFICATIONS
IS3480
Electrical
Voltage Supply:
5VDC ± 0.25V
Operating Power: 1.375 W
Standby Power: 1.0 W
Operating Current: 275 mA typical at 5VDC
Standby Current: 200 mA typical at 5VDC
DC Transformers: Class II; 5.2VDC @ 1A
For regulatory compliance information, see pages 43 – 45.
Environmental
Operating Temperature: -20°C to 40°C (-4°F to 104°F)
Storage Temperature: -40°C to 60°C (-40°F to 140°F)
Humidity: 5% to 95% relative humidity, non-condensing
Contaminants: Sealed to resist airborne particulate contaminants
Ventilation: None
required