background image

25

A

PPENDIX 

B (

CONTINUED

)

P

ARAMETER

D

EFAULT

RS-232

RS-422

L

IGHT

P

EN

Transmit SANYO ID Chr

9

9

SNI Beetle Mode

9

9

French PC Term

not

currently

supported

9

9

Xon/Xoff handshaking

9

9

Programmable prefix identifiers

9

9

Xmit (dec) as 1st prefix identifier

Xmit (dec) as 2nd prefix identifier

Programmable suffix identifiers

9

9

Xmit (dec) as 1st suffix identifier

Xmit (dec) as 2nd suffix identifier

LIGHT PEN FORMAT

POLL SRC

No/Yes

No

9

HI/OUTPUT

Bars/Code 39, Spaces/Code 39, Spaces/Code 39,
Bars/as scanned, Spaces/as scanned

Spaces/as

scanned

9

OPTIONS

Extra Transition before Bar Code

9

50x element border

9

10x narrow element border

9

1.0 ms narrow element

*

9

.50 ms narrow element

9

.30 ms narrow element

9

.15 ms narrow element

9

FORMATTING - UPC

Convert EAN-8 to EAN-13

9

9

Convert UPC-A to EAN-13

9

9

Expand UPC-E

9

9

Transmit lead zero on UPC-E

9

9

Transmit UPC-A check digit

*

9

9

Transmit UPC-A Number System

*

9

9

Transmit UPC-E check digit

9

9

Transmit EAN-13 check digit

*

9

9

Transmit EAN-8 check digit

*

9

9

FORMATTING - NONUPC

CLSI editing

9

9

Transmit Codabar Start/Stop Characters

9

9

Summary of Contents for HoloTrak IS8300

Page 1: ...METROLOGIC INSTRUMENTS INC HoloTrak IS8000 Series Holographic Scanners Installation and User s Guide...

Page 2: ......

Page 3: ...1 48 63 24 94 Email info fr metrologic com CHINA SUZHOU Metro Technologies Co Ltd SPAIN MADRID Tel 86 512 62572511 Fax 86 512 62571517 Metrologic Eria Ib rica SL Email info cn metrologic com Tel 34 91...

Page 4: ...nd Running the MetroSet 2 Program 8 Parts of the Scanner 10 Mounting Bracket Installation 11 Visual and Audible Indicators 12 Labels 13 Depth of Field and Scan Pattern Characteristics IS8300 Depth of...

Page 5: ...is based conservatively on a 0 33 mm 0 013 bar code width Actual scan areas will vary by label size and application The area defined is based conservatively on a 0 25 mm 0 010 bar code width Actual sc...

Page 6: ...00 only MX008 High Volume Speaker MLPN 52 52206 3 7 meter 12 ft Communication Cable MLPN 45 45745 MX001 for Single Scanner Setup MX001 Industrial Controller MLPN 52 52708 Communication Cable MLPN 45 4...

Page 7: ...o connect or daisy chain two scanners together to act as one scanner interfacing with only one host PRIMARY SECONDARY COVERAGE WITH ONE HOST AND TWO HOLOTRAKS Single Conveyor Two Conveyors IS8300 12 3...

Page 8: ...primary scanner and to the host 3 Connect the Primary Secondary cable to the primary scanner and the secondary scanner 4 Check the AC input requirements of the power supplies for both scanners to mak...

Page 9: ...ensor Alarm Special configuration of the MX001 Industrial controller is necessary for proper installation Please refer to the MX001 Industrial Control Interface Installation and User s Guide MLPN 00 0...

Page 10: ...tem 2 Connect the communications cable to the HoloTrak and to the host 3 Connect the External MX008 cable to the HoloTrak and the MX008 4 Check the AC input requirements of the power supply for the sc...

Page 11: ...the scanner to make sure the voltage matches the AC outlet 5 Connect the power supply to the HoloTrak 6 Plug the power supply into the AC outlet 7 Power up the host system When the hand held scanner...

Page 12: ...guration is downloaded to the primary scanner the primary will automatically configure the HoloTrak secondary scanner This step is necessary in order to configure the secondary scanner properly For al...

Page 13: ...the equipment 4 Power up the scanner 5 Turn on the PC 6 From your Start menu choose Programs MetroSet 2 MetroSet 2 7 Select Holotrak as the unit to configure 8 Then choose Configure 9 For detailed ins...

Page 14: ...Laser Output Window This aperture emits and receives laser light f D type Connector Area This area contains four D type male connectors a 25 pin 15 pin and two 9 pin D sub connectors The 25 pin connec...

Page 15: ...r with the channels on the mounting bracket 3 Slide the unit into place until the scanner bolts sit securely in the bottom of the channels 4 Rotate the unit to the desired angle and secure into place...

Page 16: ...as not been successfully read If handshaking is being used the green LED goes out when proper handshaking has completed When the green light turns off communication to the host is complete Alternating...

Page 17: ...13 LABELS A C D B...

Page 18: ...ND SCAN PATTERN CHARACTERISTICS IS8300 Depth of Field and Scan Pattern The depth of field area defined is based conservatively on a 0 25 mm 0 010 bar code width Actual scan areas will vary by label si...

Page 19: ...ND SCAN PATTERN CHARACTERISTICS IS8400 Depth of Field and Scan Pattern The depth of field area defined is based conservatively on a 0 33 mm 0 013 bar code width Actual scan areas will vary by label si...

Page 20: ...ND SCAN PATTERN CHARACTERISTICS IS8500 Depth of Field and Scan Pattern The depth of field area defined is based conservatively on a 0 33 mm 0 013 bar code width Actual scan areas will vary by label si...

Page 21: ...ND SCAN PATTERN CHARACTERISTICS IS8800 Depth of Field and Scan Pattern The depth of field area defined is based conservatively on a 0 33 mm 0 013 bar code width Actual scan areas will vary by label si...

Page 22: ...g of a bar code Therefore the output window will need occasional cleaning 1 Spray optical quality cleaning fluid onto lint free nonabrasive cleaning cloth 2 Gently wipe the output window Do not use so...

Page 23: ...connection at the host and scanner The communication cable is damaged Replace the communication cable The unit scans but does not communicate with the host Scanner configuration settings have been lo...

Page 24: ...2 720 mm 28 720 mm 28 460 mm 18 Width 460 mm 18 560 mm 22 560 mm 22 310 mm 12 Conveyor speed 1 5 mps 300 fpm 1 5 mps 300 fpm 1 5 mps 300 fpm 1 5 mps 300 fpm Mechanical Length 349 mm 13 75 349 mm 13 75...

Page 25: ...r power average 1 mW 1 mW 1 mW 1 mW Laser class CDRH Class II Class II Class II Class II Laser class EN Class 2 Class 2 Class 2 Class 2 Environmental Operating Temperature 0 C to 40 C 32 F to 104 F St...

Page 26: ...upports a function a check mark appears on the chart PARAMETER DEFAULT RS 232 RS 422 LIGHT PEN INTERFACE FORMAT RS 232 RS 422 9 9 Light Pen 9 No Comm Test Mode Only CODE TYPES All UPC EAN 9 9 9 Code 3...

Page 27: ...9 9 9 Two Compare Buffers 9 9 9 Four Compare Buffers 9 9 9 Eight Compare Buffers 9 9 9 Scan Count 9 9 9 Reverse LED convention 9 9 9 Support multiple beep B razz Z commands 9 9 Support host BEL CAN ca...

Page 28: ...9 9 9 Save read and match bar code if power down 9 9 9 SCAN RANGE Close Extended and Normal Extended 9 9 9 RESERVE CODES Reserve Code 1 99 9 9 9 RS232 FORMAT BAUD 300 38 400 9600 9 9 DATA FORMAT Odd S...

Page 29: ...ars Code 39 Spaces Code 39 Spaces Code 39 Bars as scanned Spaces as scanned Spaces as scanned 9 OPTIONS Extra Transition before Bar Code 9 50x element border 9 10x narrow element border 9 1 0 ms narro...

Page 30: ...ransmit Code 39 Mod 43 check digit 9 9 SYMBOL LENGTH ITF variable length 50 char 14 char lock 9 9 9 Min 1 50 4 9 9 9 Lock 0 50 0 9 9 9 BEEPER TONE Normal Alt1 Alt 2 Alt3 Alt4 None Normal 9 9 9 LED Fla...

Page 31: ...ut 21 Reserved 22 Reserved 23 Reserved 24 Reserved 25 Ground RS 232 Cable Note Cables for RS 232 should leave the RS 422 pins unterminated at the scanner RS 422 Cable Note Cables for RS 422 should lea...

Page 32: ...ort 9 Power Ground DESCRIPTION PIN SIGNAL 1 Flip Sense 2 Data 3 Decode LED 4 Reserved 5 Proximity Detect Connector Type on Scanner DEC9P D Type 9 Pin Male 6 Laser Motor Control 7 Ground 8 Shield Funct...

Page 33: ...Metrologic has been subjected to abuse misuse neglect improper installation or accident nor any damage due to use or misuse produced from integration of the Product into any mechanical electrical or...

Page 34: ...cified herein may result in hazardous laser light exposure Under no circumstances should the customer attempt to service the laser scanner Never attempt to look at the laser beam even if the scanner a...

Page 35: ...ser anche se credete che lo scanner non sia attivo Non aprite mai lo scanner per guardare dentro l apparecchio Facendolo potete esporVi ad una esposizione laser rischiosa L uso di apparecchi ottici eq...

Page 36: ...5 140 144 5 149 950 5 180 904 5 200 599 5 229 591 5 247 162 5 250 790 5 250 791 5 250 792 5 262 628 5 280 162 5 280 164 5 304 788 5 321 246 5 324 924 5 396 053 5 396 055 5 408 081 5 410 139 5 436 440...

Page 37: ...28 default settings 8 22 26 depth of field 1 14 15 16 17 21 design specifications 20 21 E electrical power supply 2 7 19 F failure indicator s 12 19 H host 3 4 5 6 7 8 9 12 19 23 I indicators 10 12 in...

Page 38: ...34 INDEX specifications 20 21 system interfaces 1 8 20 22 T tones 6 transformers 9 troubleshooting 19 V ventilation 21 visual 10 12 voltage 21 W warranty 29 weight 21 window 2 10 18 19...

Page 39: ......

Page 40: ...January 2004 Printed in the USA 0 0 0 2 3 7 7...