background image

 

www.metrologic.com 

10 

L

IMITED 

W

ARRANTY

 

 

The MS7580 Genesis

 scanners are manufactured by Metrologic at its Suzhou, China facility.   

The MS7580 Genesis scanners have a two (2) year limited warranty from the date of manufacture.  
Metrologic warrants and represents that all MS7580 Genesis scanners are free of all defects in material, 
workmanship and design, and have been produced and labeled in compliance with all applicable U.S. 
Federal, state and local laws, regulations and ordinances pertaining to their production and labeling. 
 
This warranty is limited to repair, replacement of product or refund of product price at the sole discretion 
of Metrologic.  Faulty equipment must be returned to one of the following Metrologic repair facilities: 
Blackwood, New Jersey, USA; Madrid, Spain; or Suzhou, China.  To do this, contact the appropriate 
Metrologic Customer Service/Repair Department to obtain a Returned Material Authorization (RMA) 
number.  
 

In the event that it is determined the equipment failure is covered under this warranty, Metrologic 
shall, at its sole option, repair the Product or replace the Product with a functionally equivalent unit 
and return such repaired or replaced Product without charge for service or return freight, whether 
distributor, dealer/reseller, or retail consumer, or refund an amount equal to the original purchase 
price.   
 
This limited warranty does not extend to any Product which in the sole judgment of Metrologic, has 
been subjected to abuse, misuse, neglect, improper installation, or accident, nor any damage due 
to use or misuse produced from integration of the Product into any mechanical, electrical or 
computer system.  The warranty is void if: (i) the case of the Product is opened by anyone other 
than Metrologic's repair department or authorized repair centers; or (ii) any software is installed on 
the Product other than a software program approved by Metrologic. 
 
THIS LIMITED WARRANTY, EXCEPT AS TO TITLE, IS IN LIEU OF ALL OTHER WARRANTIES 
OR GUARANTEES, EITHER EXPRESS OR IMPLIED, AND SPECIFICALLY EXCLUDES, 
WITHOUT LIMITATION, WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A 
PARTICULAR PURPOSE UNDER THE UNIFORM COMMERCIAL CODE, OR ARISING OUT OF 
CUSTOM OR CONDUCT.  THE RIGHTS AND REMEDIES PROVIDED HEREIN ARE 
EXCLUSIVE AND IN LIEU OF ANY OTHER RIGHTS OR REMEDIES.  IN NO EVENT SHALL 
METROLOGIC BE LIABLE FOR ANY INDIRECT OR CONSEQUENTIAL DAMAGES, 
INCIDENTAL DAMAGES, DAMAGES TO PERSON OR PROPERTY, OR EFFECT ON 
BUSINESS OR PROPERTY, OR OTHER DAMAGES OR EXPENSES DUE DIRECTLY OR 
INDIRECTLY TO THE PRODUCT, EXCEPT AS STATED IN THIS WARRANTY.  IN NO EVENT 
SHALL ANY LIABILITY OF METROLOGIC EXCEED THE ACTUAL AMOUNT PAID TO 
METROLOGIC FOR THE PRODUCT.  METROLOGIC RESERVES THE RIGHT TO MAKE ANY 
CHANGES TO THE PRODUCT DESCRIBED HEREIN. 

 

N

ORTH 

A

MERICA

 

 

 

M

ETROLOGIC 

E

UROPEAN 

R

EPAIR 

C

ENTER

Metrologic Instruments, Inc. 

 

(MERC)

 

90 Coles Rd. 

 

Metrologic Eria Ibérica, SL

 

Blackwood, NJ 08012-4683 

  C/Alfonso Gomez, 38-40, 1D 

Customer Service Department 

  28037 Madrid 

Tel: 1-800-ID-METRO 

  Tel: +34 913 751 249 

Fax: 856-228-6673 

  Fax: +34 913 270 437 

Email: [email protected] 

   

 

   

 

   

MTLG

 

A

UTO 

ID

 

I

NSTRUMENTS 

(S

HANGHAI

)

 

C

O

.,

 

L

TD

 

   

Suzhou Sales Office 

   

BLK A, Room#  03/03-04 

   

No.5 Xinghan Street, Xinsu Industrial Square 

   

China-Singapore Suahou Industrial Park, Suzhou, PRC     
Tel:  86-512-67622550 

   

Fax:  86-512-67622560 

   

Email:  [email protected] 

   

Summary of Contents for Genesis MS7580

Page 1: ...MS7580 Genesis Supplemental Guide for EAS Equipped Models ...

Page 2: ...prior written consent except by reviewer who may quote brief passages in a review or provided for in the Copyright Act of 1976 Trademarks Metrologic is a registered trademark of Metrologic Instruments Inc Products identified in this document are hereby acknowledged as trademarks registered or otherwise of Metrologic Instruments Inc or their respective companies ...

Page 3: ...tenna Connection 2 EAS System Connection 3 Checkpoint EAS System Integration 3 Configuration Imager Configuration for EAS Applications 4 Operation EAS Tag Deactivation Range 6 Scanner and Cable Terminations Scanner Pinout Connections 8 Cable Connector Configurations 9 Antenna Disconnect 9 Limited Warranty 10 ...

Page 4: ......

Page 5: ...ecified cables listed below Any damage incurred from incorrect cable usage will void the limited warranty shown on page 10 EAS Cable Options Part Description The following cables are compatible with Checkpoint System devices MX 5S000 E 3 RS232 12V VLink Straight Black Cable with Built in Power Jack MX 5S235 E 3 USB 12V VLink Straight Black Cable with Built in Power Jack Non Locking Type A Connecto...

Page 6: ...ottom of the imager s stand 2 Remove the socket screw securing the connector cover A 1 5 mm hex key is supplied 3 Remove the connector cover plate by lifting up the end and sliding the cover to the left 4 Insert the 2 pin box plug A into the receptacle on the imager s stand see Figure 2 5 Insert the cable s strain relief B into the channel on the stand see Figure 2 6 Re install the connector cover...

Page 7: ...re Gauge Connection Type Solid Light Green Thin INTLK Terminal Solid Black Thin INTLK Terminal GND Interlock Red and White Thick Antenna Terminal Black and White Thick Antenna Terminal No Insulation Shield Antenna Shield Antenna Interlock functionality requires specific EAS device settings Consult the manufacturer s EAS system documentation for the appropriate switch and timing potentiometer setti...

Page 8: ...below Disable EAS Support 3 3 7 2 0 0 2 Scan either the Enable Continuous Mode bar code or the Enable Regular Mode bar code Enable Regular Mode Regular Mode In regular EAS mode the imager will signal the EAS system to activate immediately after the area imager successfully transmits a bar code The area imager will signal the EAS system to deactivate after the configured EAS timeout expires 1 4 6 1...

Page 9: ...will leave the EAS interlock signal asserted following a successful scan If the area imager commonly fails to deactivate EAS tags try increasing the value of the timeout setting Note The EAS timeout setting has no effect in continuous mode EAS Timeout 100 ms 8 4 6 0 0 0 EAS Timeout 500 ms 8 4 6 0 5 0 EAS Timeout 1s 8 4 6 0 1 0 0 EAS Timeout 5s 8 4 6 0 5 0 0 ...

Page 10: ...e expected deactivation range Tag Storage Precaution Do not store tags within 45 7 cm 18 0 of the MS7580 Tags stored closer than 45 7 cm 18 0 may be unintentionally deactivated The precautionary area includes storage areas located under the MS7580 Proper tag deactivation requires the entire tag to pass through the expected tag deactivation range indicated in figures 4 and 5 Figure 4 Expected Tag D...

Page 11: ...7 OPERATION Figure 5 Expected Tag Deactivation Area Top View Specifications are subject to change without notice ...

Page 12: ...nect 4 No Connect 4 Tied to Pin 2 in Cable 5 Reserved 5 Reserved 6 RTS Output 6 USB D 7 No Connect 7 5VDC USB Power 8 RS232 Transmit Output 8 USB D 9 12V Power 9 12V Power 10 Shield Ground 10 Shield Ground SHELL Signal Power Ground SHELL Signal Power Ground 2 Pin Box Receptacle EAS Pin Function 1 EAS ANT 2 EAS ANT Figure 7 USB requires 12V power for pass through functionality Signals on Pin 6 and ...

Page 13: ...00 E 3 Pin Function 1 Shield Ground 2 RS232 Transmit Output 3 RS232 Receive Input 4 No Connect 5 Power Signal Ground 6 DSR 7 CTS Input 8 RTS Output 9 Host 12VDC Figure 8 9 Pin Female D Type USB MX 5S235 E 3 Pin Function 1 PC 5V V_USB 2 D 3 D 4 Ground Figure 9 USB Type A Non Locking Antenna Disconnect Figure 10 ...

Page 14: ...duced from integration of the Product into any mechanical electrical or computer system The warranty is void if i the case of the Product is opened by anyone other than Metrologic s repair department or authorized repair centers or ii any software is installed on the Product other than a software program approved by Metrologic THIS LIMITED WARRANTY EXCEPT AS TO TITLE IS IN LIEU OF ALL OTHER WARRAN...

Page 15: ......

Page 16: ...00 05269A November 2008 Printed in China 2008 Metrologic Instruments Inc ...

Reviews: