metrofires Ultra Insert Installation & Owner'S Operation Manual Download Page 1

Important information ..................................... 2
Pre-installation requirements .......................... 2
Installing your Metro ....................................... 3
Firebox parts and components ....................... 5
Ultra Insert flue kit installation ........................ 6
Chimney vent requirements ............................ 8
Floor protector requirements .......................... 9

Getting to know your Metro ........................... 10
Replacement parts & accessories ................. 11 
Operating your Metro ................................... 11
Cleaning and maintenance  .......................... 13
Troubleshooting ........................................... 14
Metro warranty ............................................. 15

Ultra Insert Wood Fire

Wood Fire Installation & Owner’s Operation Manual

19 Oropuriri Road // New Plymouth 4312 
[email protected] // www.metrofires.co.nz

04/19 © PIONEER MANUF

ACTURING L

TD

B

G

C

F

D

605mm maximum

 

Height adjustable panel

Summary of Contents for Ultra Insert

Page 1: ...quirements 9 Getting to know your Metro 10 Replacement parts accessories 11 Operating your Metro 11 Cleaning and maintenance 13 Troubleshooting 14 Metro warranty 15 Ultra Insert Wood Fire Wood Fire In...

Page 2: ...lue pipe exposed A rear cavity vent is required Please see detail in Diagram 1 opposite with full cavity vent requirements and installation detailed on page 8 of this manual In New Zealand the Metro U...

Page 3: ...lation instructions detailed on page 6 proceed and fit the flue with All JOINTS SEALED and riveted with a minimum of three stainless steel or monel rivets on each joint 7 With Pioneer fire cement appl...

Page 4: ...or cabinet Ensure the fan rotates freely 4 Rotate the door handle fully anti clockwise before placement of the fascia The inner fascia slips snugly into the cabinet with the Top Rail of the fascia res...

Page 5: ...s in its correct position in the top chamber of the firebox It should be resting on four support lugs two on each side of the firebox The baffle must be hard back against the rear wall of the firebox...

Page 6: ...omponents A 1 x Stainless steel weather butterfly B 1 x Stainless steel ECO Cowl top C 1 x 420mm x 240mm diameter stainless steel ECO Cowl housing D 1 x 480mm long stainless steel flue pipe extension...

Page 7: ...eather butterfly A so the angled sections are facing up With both arms and angled sections of the stainless steel weather butterfly A facing up fit it into the stainless steel ECO Cowl top B and secur...

Page 8: ...nd bead off around the perimeter Fill the weather seal groove with silicon and embed the weather strip fully into the silicon to ensure weather tightness Chimney vent requirements 230mm Maximum height...

Page 9: ...de of the door opening making the minimum floor protector width 825mm The insulated floor protector must project from behind the fascia the distance specified I in the table below Minimum projection i...

Page 10: ...baffle plate promet extension white board on the baffle plate It is critical that the fire not be operated with cracked or broken door glass It is critical that the fire is operated with the fan switc...

Page 11: ...easoned 12 months later Burning properly seasoned dry fuel will result in Less ash buildup Less emission into the environment Less creosote that can cause a host of issues Maintain a clean flue system...

Page 12: ...latch After 2 minutes with the kindling well alight fully close the door Intermediate load with air control fully open Approximately 40 minutes after lighting once remaining fuel has formed hot coals...

Page 13: ...epends on the density and cleanliness of your fuel To remove the excess ash your Metro should not be operating Open the door and using a hearth shovel or similar empty the excess ash directly into a s...

Page 14: ...We highly recommend the Metro ECO Cowl is fitted as this will increase the draw If you already have an ECO Cowl and smoke is still entering the room please add another 600mm length of flue pipe Downd...

Page 15: ...the life span will be reduced If your Metro wood fire has been neglected by not being regularly maintained and serviced warranty may be declined It is critical the fire not be operated with over worn...

Page 16: ......

Reviews: