DC3445 SPECIFICATIONS
13
5 DC3445 SPECIFICATIONS
5. 1 DC3445 Product Specification
Parameter
Definition
E3/DS3 LINE
Interface
G.703 compliant, Sensitivity -10dB.
E3 Line coding HDB3. DS-3 Line coding B3ZS
Interface type:
75 Ohm unbalanced coax, BNC connectors
Jitter Tolerance
Per G.823.
Barrier
EN 41003 compliant barrier provided on the E3/DS3 LINE
interface.
DTE Interface
HSSI:
50 way miniature AMP connector
Clocking options
E3/DS3 LINE port:
Circuit 113 (normally slaved to Circuit 114)
DTE port (Circuit 114):
INTERNAL, LOOP
DTE Receive timing RT:
Circuit 115 is always sourced from
the E3/DS3 Receive clock
Diagnostics
Loop Test initiated by Bit-switch
General
Definition
Power supply
100-250 VAC, 50-60 Hz, 115-45 mA or
-36 to -72 VDC, 150-70 mA
Dimensions
202 x 132 x 44 mm (w x d x h) Enclosure only
202 x 132 x 47 mm (w x d x h) Overall including feet
Environmental
Range
Ambient Temperature 0 degC to +50 degC
Storage Temperature
-20 degC to +70 degC
Relative Humidity
0% - 95% non condensing
Barometric Pressure
86 KPa - 106 KPa