8
oPeRaTInG InSTRUCTIonS
Power-Up & Pre-Heat
Your C5 1 SerieS or 3 SerieS Cabinet maY be equipped with Several different moduleS:
C5 1 SERIES
C5 3 SERIES
COMBINATION PROOF & HOLD MODULE
COMBINATION PROOF & HOLD MODULE
HOLDING MODULE
HOLDING MODULE
PROOFING MODULE
MOISTURE HOLDING MODULE
A. Refer to the data plate located near the power cord for the electrical specifications of cabinet as shown on page 3.
• With the the POWER switch OFF, plug the cord into the appropriate rated, grounded receptacle.
• Cabinets rated at 120V 1440W must be plugged into either a 15 amp or 20 amp 125VAC receptacle.
• Cabinets rated at 120V 2000W must be plugged into a 20 amp 125VAC receptacle.
• Cabinets rated at 220-240V must be plugged into a 15 amp 250VAC receptacle.
B. With POWER switch OFF, plug into a grounded receptacle.
C. Fill the stainless steel water pan to
1
/
2
" from the top with clean HOT tap water for Proofing or if moisture is desired
for Holding. Check water level every 3 hours (2 hours when Proofing) and refill with clean HOT tap water as
necessary. Water pan does not have to be filled for Holding. Proofing and Moisture Holding Module require water
pan to be filled if moisture control is turned on.
HOLDING INSTRUCTIONS (Combo, Holding & Moisture Holding)
1. Set Combination Module switch to
HOLD.
2. Set POWER switch to the
ON
position.
3. Set TEMPERATURE control to
10.
4.
On Moisture Holding only:
Set MOISTURE
control to
10.
5. Pre-heat cabinet until desired temperature
is reached (typical heat-up time from 72°F (22°C)
ambient to 160°F (71°C) is approximately
45 minutes).
6. Re-set TEMPERATURE control and adjust as
necessary to reach the desired temperature
(setting 6-8 typical for 150°F (66°C) to 160°F
(71°C)). Power indicator light will turn on
and off as the heat thermostat cycles.
7.
On Moisture Holding only:
Adjust
MOISTURE
control to desired level (10 being highest level,
1 lowest level,
OFF
being no heat to the water).
The indicator lights will turn on and off as the
heat and moisture thermostats cycle.
PROOFING INSTRUCTIONS (Combo & Proofing)
1. Set Combination Module switch to
PROOF.
2. Set POWER switch to the
ON
position.
3. Set TEMPERATURE control to
2.
4. Set MOISTURE control to
10.
5. Pre-heat cabinet until desired temperature
and humidity is reached (typical heat-up time
from 72°F (22°C) ambient to 95°F (35°C) and
95% relative humidity is approximately
30 minutes).
6. Adjust settings as necessary to reach the
desired temperature and humidity levels.
Power indicator lights will turn on and off
as the heat and moisture thermostats cycle.
7. Adjust
MOISTURE
control to desired level
(10 being highest level, 1 lowest level,
OFF
being no heat to the water). The indicator
lights will turn on and off as the heat and
moisture thermostats cycle.
When the power switch is on, the blower is always energized, circulating air, and the digital thermometer is always
displaying the cabinet temperature. When the thermostat senses heat is required, the appropriate indicator will light
and the heater element will begin to produce heat.
• At the end of the operating day, it is not necessary to disrupt the temperature setting to turn the cabinet off. By
switching the power switch off, the cabinet is no longer operating. When resuming operations, switch the power
on and the cabinet will attain the previous temperature and moisture levels.
M
oi
st
ur
e
H
ol
di
ng
M
od
ul
e
MOISTURE
HOLDING
MOISTURE
HOLDING
M
oi
st
ur
e
H
ol
di
ng
M
od
ul
e
Figures Shown in °F