background image

Chapter II 

Portable digital multimeter 

29 

5.6. Capacitance 

 

)

 

Note 

Discharge all capacitors before taking measurements. 

 

Ranges Accuracy 

Measurement 

current 

Max measurement 

time 

Protection

 

Resolution 

50 nF

∗∗

 

100 nA 

10 pF 

500 nF 

1 µA 

100 pF 

5 µF 

10 µA 

1 nF 

50 µF 

100 µA 

0.5 s 

10 nF 

500 µF 

1% R + 2D 

1.5 s 

100 nF 

5000µF 

3 s/mF 

1 µF 

50 mF 

2% R + 2D 

1 mA 

3 s/mF 

600 V

RMS

 

10 µF 

 Overload protection can be reset automatically. 

∗∗ 

It is highly recommended to use very short and shielded test leads for measurements in            

this range. 

Number of count : 

5000 

Range selection : 

automatic or manual 

Maximum open circuit voltage : 

7 V 

5.7. Diode 

threshold 

voltage measurement 

 

Measurable voltages : 

0 to 2 V 

Measurement current : 

1 mA typical 

Resolution : 

1 mV 

Protection : 

600 V

RMS

, can be reset automatically 

5.8. Frequencies 

 

Selector switch setting : 

V

AC

 + SEL/ON 

Measurement range : 

0.62 Hz to 500 kHz 

Accuracy : 

0.03 % 

Protection : 

600 V

RMS

 

Display : 

50.000 count 

Range

Sensitivity

5 V to 500 V 

600 V 

0.62 Hz to 5 kHz 

 

2 % of range 

100 V 

5 kHz to 50 kHz 

5 % of range 

250 V 

50 kHz to 500 kHz 

10 % of range 

//////////////// 

 Rectangular signals 

5.9. 

Duty cycle %+, %- 

 

θ

T

θ

T

% - = 

θ

T

x 100

% + = 

θ

T

x 100

Resolution : 0.01 % 
Min. duration for 

θ

 or T-

θ

 : 2 µs

Max. duration for T : 0.8 s 
Min. duration for T : 100 µs 

Absolute error as a % : 

T

4

10

.

3

Sensitivity : see frequency measurement mode 
Absolute additional error on 

θ

, due to the zero crossing slope : 

0.1 x 

P

C

with C : range in V (C = 5000 V for 600V

DC

 or 600 V

AC

 ranges) 

with P :  slope in V/s 

Summary of Contents for MX 58HD

Page 1: ...istruzioni Manual de instrucciones ENGLISH page 16 Chapter II Office Jl Radin Inten II No 62 Duren Sawit Jakarta 13440 Indonesia Workshop Jl Pahlawan Revolusi No 22B Jakarta 13430 Indonesia Phone 021...

Page 2: ...Multim tre digital portable 8 9 7 10 11 12 13 5 20 6 19 18 17 16 15 14 1 2 3 4...

Page 3: ...14 Widerstandsmessung 5 Multimeter Einschalten Zweitfunktionen 15 Kapazit tsmessung 6 Bereichsumschaltung 16 Strommessung bis 5 mA 7 Relativ Messung 17 Strommessung bis 50 mA 8 Spitzenwertmessung 18...

Page 4: ...test leads 21 3 2 Switching on the instrument 21 3 3 Switching off the instrument 21 3 4 Special configurations 21 3 5 Multimeter maintenance 22 4 FUNCTIONAL DESCRIPTION 23 4 1 SEL ON key 23 4 2 RANGE...

Page 5: ...rformed on circuits not directly connected to mains E g protected electronic circuits CAT II Measurement category II is for measurements performed on circuits directly connected to the low voltage ins...

Page 6: ...rent and make sure not to be loaded with static electricity which may destroy internal components Fuses must be replaced with fuses of the same rating and type Any adjustment maintenance or repair wor...

Page 7: ...related software without the explicit authorization of the manufacturer Repairs necessitated by attempts to repair or maintain the product made by a person not approved by the manufacturer Adaptation...

Page 8: ...threshold voltage frequencies duty cycles 2 2 Keypad A six key keypad lets you select the autoranging mode RANGE key freeze a value HOLD key measure fast peaks Pk key set the measurement relative to...

Page 9: ...lly by returning the selector switch to the OFF position or automatically after approximately half an hour if no key is pressed or the switch is not operated Note Automatic shutdown of the instrument...

Page 10: ...n appears on the display the instrument still has approximately 50 hours of operation but specifications can no longer be guaranteed Replace the battery 3 5 3 Replacing the battery or fuses Disconnect...

Page 11: ...sed to access secondary functions associated with the selector switch positions The flowcharts below define these various functions 4 1 1 VAC position 4 1 2 mV position SEL ON SEL ON DC voltage measur...

Page 12: ...imeter 4 1 3 VDC position 4 1 4 position 4 1 5 position SEL ON SEL ON AC DC voltage measurement DC voltage measurement SEL ON SEL ON Continuity test Resistance measurement SEL ON SEL ON Diode voltage...

Page 13: ...RANGE key is used to change from one range voltage to the next range The new range is then displayed for 2 seconds 4 3 REL key Short press Mode REL the last value measured becomes the reference value...

Page 14: ...urement is stable When you remove the probes a second audible signal indicates that this stable value displayed has been stored 4 6 PRINT key This key operates with the optional serial interface for p...

Page 15: ...Serial mode rejection at 50 and 60 Hz better than 60 dB Additional error in Pk mode for a pulse of 1 ms 1 R 50 D For measurements performed on alternative signals the selected range must tally with t...

Page 16: ...1 F2 100 A 1 A 1 5 V 10 A 1 5 R 3 D 2 kHz 1 5 typ 600 VRMS F2 10 mA 30 A 500 mV refer to fuse specifications section 6 1 1 acceptance overload 20 A during 30 s max observing a break 5 min between 2 te...

Page 17: ...threshold voltage measurement Measurable voltages 0 to 2 V Measurement current 1 mA typical Resolution 1 mV Protection 600 VRMS can be reset automatically 5 8 Frequencies Selector switch setting VAC S...

Page 18: ...0 M 0 to 70 from 40 C to 50 C 60 above 50 C Casing and circuit self extinguishing materials Operating quality IEC 359 Electromagnetic compatibility Emission Immunity EN 61326 1 Max influence in electr...

Page 19: ...ps 0 5 to 240 AAC 20 mm MN09 0 1 to 1200 AAC 52 mm CI03 0 5 to 1000 AAC 39 mm PAC 20 0 5 to 1000 AAC 39 mm PAC 21 Shunts 30 A 300 mV HA030 1 50 A 100 mV HA050 Miscellaneous Set of RS232 serial link SX...

Reviews: