3
Manufacturer’s declaration
Declaration of Conformity (see Annex A, page 34)
4
Applications for the MQMe Quantometer
The MQMe Quantometer is designed for metering the volume of natural gas used within a
company and is approved in accordance with European Regulation 2014/68/EU.
The MQMe Quantometer can be installed in potentially explosive atmospheres in category
1G (ATEX / IECEx Ex Zone 0) Ex ia II C T4 Ga (Annex B).
The MQMe Quantometer is suitable for measuring the volume of the following gases:
•
Natural gas, town gas, propane, butane, ethylene, air, nitrogen and noble gases
•
Other gases can be metered on request
Note:
The MQMe Quantometer is not suitable for oxygen and highly corrosive gases,
acetylene and other aggressive gases or explosive gases and gas mixtures.
Note:
The MQMe Quantometer should not be used in the presence of strong
pulsations. These conditions will increase the number of measurement errors and
could significantly reduce the service life of the MQMe Quantometer.
5