3  Power Supply and Electrical Specification

The QuasarMX is powered using 24V DC which are connected at the front of the device

(X3). If you do not use a power supply supplied by metraTec, please make sure that your
own   PSU   provides   a   supply   voltage   of   high   quality.   If   possible,   use   a   PSU   with   high

precision/high speed linear regulator. If you use a switching PSU, please make sure that the
switching frequency is > 500 kHz.

Connector

Description

X3.1

GND

X3.2

24V DC

Tab. 1: 

Description of Power Connector

Operating Voltage

24 V DC

Power Consumption

1

, RF on

200 mA

Power Consumption

1

, RF off

80 mA

Power Consumption

1

, Sleep

20 mA

Voltage Inputs/Outputs

24 V

Tab. 2: Maximum Rating and Electrical Limits

1 Note: For Ethernet power consumption is increased by 250 mA.

Technical Documentation metraTec QuasarMX

                                                               Page 6 of 13

Fig. 2: Power Connector Description (ref. Tab. 1)

Summary of Contents for QuasarMX

Page 1: ...Technical Documentation for metraTec QuasarMX HF RFID Reader Date December 2016 Version 1 5 Technical Documentation metraTec QuasarMX Page 1 of 13...

Page 2: ...Intended Use 4 2 2 Technical Specification 4 2 3 Product Drawing 5 2 4 Scope of Delivery 5 2 5 Accessories 5 3 Power Supply and Electrical Specification 6 4 Communication 7 4 1 USB Driver Installatio...

Page 3: ...light control systems life support systems or weapon systems The manufacturer denies the suitability of this device for such scenarios 1 3 Export Restrictions The QuasarMX contains components that und...

Page 4: ...rom a normal PC with a full operating system with embedded systems as well as with a PLC 2 1 Intended Use RFID Reader Writer for wireless communication with RFID transponders according to ISO 15693 2...

Page 5: ...ilable via download from metraTec s website http www metratec com Support Downloads 2 5 Accessories The following accessories and modules are available to extend and evaluate the functionality of the...

Page 6: ...gulator If you use a switching PSU please make sure that the switching frequency is 500 kHz Connector Description X3 1 GND X3 2 24V DC Tab 1 Description of Power Connector Operating Voltage 24 V DC Po...

Page 7: ...with WiFi and ZigBee are available on special request 4 1 USB Driver Installation The basic option for connecting the QuasarMX with your host PC is using the USB connection every reader has 1 Connect...

Page 8: ...om To connect the antenna to the reader or multiplexer the devices are equipped with BNC jacks and the cables are equipped with BNC plugs at both ends When connecting antennas with multiplexers or rea...

Page 9: ...rrent of 250 mA per pin These can be used to directly power e g signal towers In total a maximum current of 1000 mA for all pins is allowed Outputs are equipped with internal overcurrent and overtempe...

Page 10: ...Out 2 X2 6 Out 2 X2 7 Out 3 X2 8 Out 3 X2 9 Out 4 X2 10 Out 4 X2 11 In 1 X2 12 In 1 X2 13 In 2 X2 14 In 2 X2 15 GND X2 16 24 V DC Tab 3 Pin Description for digital IOs Note All Out X are connected to...

Page 11: ...metals and other harmful substances as required by the RoHS Directive for many industries Hence our products are produced in the most environmentally friendly way possible 7 2 Declaration of Conformi...

Page 12: ...2 minor corrections and layout changes CS 06 08 2014 1 3 corrected scope of delivery German version CS 30 10 2014 1 4 HF Antenna Integration Guide mentioned USB driver installation description removed...

Page 13: ...c GmbH Reprint or reproduction of this documentation for other than internal purposes is only allowed with written permission by metraTec GmbH All trademarks are the property of their respective owner...

Reviews: