background image

Glucose Test Strips

IMPORTANT: Please read this information and your Gluceofine® operation manual before using the Gluceofine®  

glucose test strips. 

Warning! To avoid false readings, use only a Gluceofine® Meter to measure glucose with your Gluceofine® 

                  Glucose Test Strips. 

Intended Use: 

The Gluceofine® Glucose Test Strips are used with Gluceofine® Glucose Test Meter for the measurement of glucose in 

your blood. The Gluceofine® Blood Glucose Monitoring System is plasma-calibrated to allow comparison of results 

with the laboratory method. The Gluceofine® Glucose Test Strips are for testing outside the body (in vitro diagnostic 

use only). Gluceofine® Blood Glucose monitoring system is for self-testing.

General :

Gluceofine® glucose test strips adopt a new bio-sensor technology composed of electro-chemical components and 

require a small 0.5µl volume of blood giving you less pain. Gluceofine® can store 365 readings in memory with date 

& time, you can easily store your readings on your PC (optional). This will provide an easier and better way to control 

your glucose levels.

Storage and Handling :

t4UPSFUIF(MVDFPöOF® Glucose Test Strip vials in a cool and dry place between 2-30°C(36-86°F). Keep out of direct 

sunlight. Do not freeze. 

t4UPSF(MVDPTF5FTU4USJQTJOUIFJSPSJHJOBMWJBMPOMZ%POPUNJYUIF(MVDPTF5FTU4USJQTJOOFXWJBMTPSJOBOZPUIFS

container.

t*NNFEJBUFMZSFQMBDFUIFDBQBOEDMPTFUJHIUMZBGUFSSFNPWJOHB(MVDFPöOF® Glucose Test Strip.  

t6TFFBDI(MVDPTF5FTU4USJQJNNFEJBUFMZBGUFSSFNPWJOHJUGSPNUIFWJBM

t%POPUVTF(MVDPTF5FTU4USJQTBGUFSUIFFYQJSZEBUFQSJOUFEPOUIFQBDLBHFPSWJBMTJODFJUNBZDBVTFJOBDDVSBUF

results.

t.BLFBOPUBUJPOPGUIFEJTDBSEEBUFPOUIFWJBMMBCFMXIFOZPVöSTUPQFOJU

   Discard remaining Gluceofine® Glucose Test Strips 3 months after first opening the vial.

t"WPJEHFUUJOHEJSUGPPEBOEXBUFSPOUIF(MVDPTF5FTU4USJQ%POPUIBOEMF(MVDPTF5FTU4USJQTXJUIXFUIBOET

t%POPUCFOEDVUPSBMUFSBOZ(MVDFPöOF® Glucose Test Strip.

t(MVDFPöOF® Glucose Test Strips are for single use only. Do not re-use. 

t%POPUQFSGPSNUFTUTBUUFNQFSBUVSFTCFMPX¡$ ¡'PSBCPWF¡$ ¡'%POPUQFSGPSNUFTUTXJUIIVNJEJUZ

CFMPXPSBCPWF

t#FDBSFGVMOPUUPQPMMVUFUIFDPMPSDPEJOHMBCFM 1PMMVUFEDPMPSDPEJOHMBCFMEVFUPEVTUBOEPUIFSTVCTUBODFT

t%JTDBSEUIFVTFE(MVDPTF5FTU4USJQDBSFGVMMZUPQSFWFOUBOZJOGFDUJPO

t,FFQUIF5FTU4USJQTBXBZGSPNDIJMESFO

Care Procedures : 

t%POPUSFVTFHMVDPTFUFTUTUSJQT4JOHMFVTFPOMZ

t*GZPVFYQFSJFODFBOZTZNQUPNTUIBUBSFOPUDPOTJTUFOUXJUIZPVSCMPPEHMVDPTFUFTUSFTVMUTBOEZPVIBWFGPMMPXFE

the instructions described in your Gluceofine® Meter Manual, call your physician. 

t%POPUNBLFTJHOJöDBOUDIBOHFTUPZPVSEJBCFUFTDPOUSPMQSPHSBNXJUIPVUDPOTVMUJOHZPVSQIZTJDJBO

t%POPUJHOPSFQIZTJDBMTZNQUPNTXJUIPVUDPOTVMUJOHZPVSQIZTJDJBO

Test Principle :

Glucose in the blood sample will react to the electrodes in the glucose test strip, generating an electrical current that 

will stimulate a chemical reaction. This reaction is measured by the Gluceofine® meter and displayed as your blood 

glucose result. 

Reagent Composition :

Each Gluceofine® glucose test strip contains: 

(MVDPTF0YJEBTF "TQFSHJMMVTOJHFS 

6OJUT

.FEJBUPS )FYBBNNJOFSVUIFOJVNDIMPSJEF

 

#JOEFS

 

4UBCJMJ[FS 

The procedure for Blood Glucose Measurement :

Materials needed: Gluceofine® Test Strips, Gluceofine® meter, operation manual, lancing device, sterile lancet

Obtaining Blood Sample :

The Gluceofine® Glucose Test Strips are designed to be used with fresh capillary whole blood.  You may obtain a blood 

drop from either a fingertip or an alternative site (see meter manual).

To obtain a drop of blood, follow these steps :

Step 1:  Cleanliness 

Wash your hands and test site with warm water. Dry it thoroughly.  (Dirt, oil, lotion, or 

sweat may affect the test result).

Step 2:  Lancing

Prepare the lancing device. Insert a lancet into the lancing device. The device holds, 

QPTJUJPOTBOEDPOUSPMTIPXEFFQMZUIFMBODFUHPFTJOUPUIFTLJO 3FGFSUPUIFPXOFST

manual for more information).

Step 3: Insert the Glucose Test Strip

Remove a test strip from the vial. Recap the vial immediately to prevent moisture 

from affecting the other strips. Insert the test strip into the port of the meter, with 

arrow sign facing up and showing towards the meter. The meter will automatically 

UVSOPOBOEEJTQMBZUIFDPEFOVNCFS.BLFTVSFUIBUUIFDPEFPOZPVSNFUFSEJTQMBZ

matches the code number printed on the test strip vial. If not matching repeat this 

step.

The test strip icon with a drop of blood will be flashing at the top of the meter display. 

You are now ready for testing.

Step 4: Obtain and apply the blood sample

 

1MBDFUIFMBODJOHEFWJDFBHBJOTUUIFBSFBUPCFQSJDLFEGPSFYBNQMFUIFöOHFSUJQ'PS

a correct test result, an amount of 0,5µl is necessary. While the symbol for apply is 

flashing, place the drop of blood on your finger against the slim end of the test strip 

until the window is completely filled. Do not press your finger against the test strip. 

Do not try to wipe off the blood with the test strip. A beep sound confirms, when the 

window is correctly filled. If you have a poor amount of blood: Run a new test whith a 

NEW test strip!

 

Step 5: Measurement result in 5 seconds

5IF NFUFS BVUPNBUJDBMMZ TUBSUT UFTUJOH *U DPVOUT EPXO GSPN  UP  EJTQMBZT UIF

NFBTVSFNFOU SFTVMU BOE TUPSFT JU BVUPNBUJDBMMZ  5P TUPSF XJUI 6TFShT "DUJWJUZ BOE

6TFS*%QMFBTFSFGFSUPZPVSNFUFSNBOVBM6TFUIFUFTUTUSJQFKFDUPSUPSFNPWFUIF

test strip. The meter will automatically turn off.

Important Information About Using Alternate Site Testing :

t"MUFSOBUFTJUFTXIFSFZPVDBOUFTUBSFEPSTBMIBOEWFOUSBMQBMNVQQFSBSNGPSFBSNDBMGBOEUIJHI

t6OEFSDFSUBJODPOEJUJPOTCMPPEHMVDPTFUFTUSFTVMUTPCUBJOFEVTJOHTBNQMFTUBLFOGSPNZPVSBMUFSOBUFTJUFTNBZ

differ significantly from fingertip samples.

t8IFOCMPPEHMVDPTFJTDIBOHJOHSBQJEMZöOHFSUJQTBNQMFTTIPXUIFTFDIBOHFTNPSFRVJDLMZUIBOBMUFSOBUFTJUFT

samples. 

t8IFOZPVSCMPPEHMVDPTFJTGBMMJOHUFTUJOHXJUIBöOHFSUJQTBNQMFNBZJEFOUJGZBIZQPHMZDFNJD MPXCMPPETVHBS

level sooner than a test with a alternate sites sample.

t6TFBMUFSOBUFTJUFTTBNQMFTPOMZGPSUFTUJOHQSJPSUPPSNPSFUIBOUXPIPVSTBGUFSNFBMJOTVMJOEPTFTPSQIZTJDBM

FYFSDJTF

t5FTUJOHQFSGPSNFEXJUIJOUXPIPVSTBGUFSNFBMTJOTVMJOEPTFTPSQIZTJDBMFYFSDJTFPSXIFOFWFSZPVGFFMUIBUZPVS

glucose levels may be changing rapidly should be done from the fingertip.

t:PVTIPVMEBMTPVTFöOHFSUJQUFTUJOHXIFOFWFSZPVIBWFBDPODFSOBCPVUIZQPHMZDFNJB JOTVMJOSFBDUJPOTTVDIBT

XIFOESJWJOHBDBSQBSUJDVMBSMZJGZPVTVòFSGSPNIZQPHMZDFNJDVOBXBSFOFTT MBDLPGTZNQUPNUPJOEJDBUFBTJOTVMJO

reaction), as forearm testing may fail to detect hypoglycemia.

Test Results : 

The results are displayed on the Gluceofine® meter as either milligrams of glucose per deciliter of blood (mg/dL) or 

NJMMJNPMFTPGHMVDPTFQFSMJUFSPGCMPPE NNPM-5IFHMVDPTFUFTUNFUFSEJTQMBZTSFTVMUTCFUXFFO_NHE-

 _NNPM-

*GUIFUFTUSFTVMUJTCFMPXNHE- NNPM-i-PwXJMMBQQFBSPOUIF(MVDFPöOF® meter display. Consult with your 

EPDUPS JNNFEJBUFMZ JO IPX UP USFBU FYUSFNFMZ MPX CMPPE HMVDPTF  IZQPHMZDFNJB *G UIF UFTU SFTVMU JT BCPWF

NHE- NNPM-i)Jw XJMM BQQFBS PO UIF (MVDFPöOF® NFUFS EJTQMBZ5IJT JOEJDBUFT FYUSFNFMZ IJHI CMPPE

HMVDPTF IZQFSHMZDFNJB4FFLNFEJDBMBTTJTUBODFJNNFEJBUFMZ

When the glucose control solution is applied to the top edge of the glucose test strip, you should get results within 

UIFFYQFDUFESBOHFQSJOUFEPOUIFMBCFMPGUIFHMVDPTFUFTUTUSJQWJBM*GUIFHMVDPTFDPOUSPMTPMVUJPOUFTUSFTVMUTGBMM

outside the range, repeat the test with a new strip. Results that fall out-side the range may be caused by:

t&SSPSJOQFSGPSNJOHUIFUFTU

t'BJMVSFUPTIBLFUIFDPOUSPMTPMVUJPOCPUUMFXFMMFOPVHI NVTUTIBLFWJHPSPVTMZ

t'BJMVSFUPEJTDBSEUIFöSTUESPQPGDPOUSPMTPMVUJPO

t&YQJSFEPSDPOUBNJOBUFEDPOUSPMTPMVUJPO

t(MVDPTF5FTU4USJQEFUFSJPSBUJPO

t(MVDPTF5FTU.FUFSNBMGVODUJPOT

t$POUSPMTPMVUJPOUFTUTUSJQBOEPSNFUFSJTOPUBUSFDPNNBOEFEUFNQFSBUVSFMFWFM ¡$

IMPORTANT NOTE: If the Gluceofine® Glucose Control Solution test results continuously falls outside the range 

printed on the vial, the Gluceofine® Blood Glucose Monitoring system may not be functioning properly. DO NOT 

use the Gluceofine® Blood Glucose Monitoring system to test your blood until you get a glucose control solution 

test result that falls within the range. If you continue to have problems, contact Metrado GmbH or your local 

representative immediately.

 

Limitations of System :

The Gluceofine® Glucose Test Strips provide accurate results when the following constraints are followed: 

t%POPUVTFOFPOBUFTBNQMFT

t6TFGSFTIDBQJMMBSZXIPMFCMPPEPOMZ

t%FIZESBUJPONBZMPXFSUFTUSFTVMUT

t*OBDDVSBUFSFTVMUTNBZPDDVSXIFOJOTIPDLIZQPUFOTJWFIZQFSHMZDFNJDPSIZQFSPTNPMBSTUBUFXJUIPSXJUIPVU

LFUPTJT

t(MVDPTFUFTUTUSJQTVTFEJOBMUJUVEFTBCPWFGFFUXJMMIBWFBOBòFDUPOUFTUSFTVMUT

Physicians - Please note the following interferences that may affect test results :

4)

t&YUSFNFTJOIFNBUPDSJUNBZBòFDUUFTUSFTVMUT*GUIFIFNBUPDSJUSBOHFJTPVUPGUIFSBOHF _UIFOUIFUFTU

results may be lower or higher than actual value. 

t*OUFSGFSFODFT"DFUBNJOPQIFO6SJDBOE"TDPSCJDBDJE 7JUBNJO$BOEPUIFSSFEVDJOHTVCTUBODFTXIFOPDDVSSJOH

in normal blood or normal therapeutic concentrations do not significantly affect results. However, abnormally high 

concentrations in may cause inaccurately high results.

t-JQFNJDTBNQMFT$IPMFTUFSPMVQUPNHE-PSUSJHMZDFSJEFVQUPNHEMEPOPUTJHOJöDBOUMZBòFDUUIFSFTVMUT

7BMVFTCFZPOEUIFTFMFWFMTTIPVMECFJOUFSQSFUFEXJUIDBVUJPO

t#MPPETBNQMFTUIBUDPOUBJOBIJHIDPODFOUSBUJPOPGEJTTPMWFEPYZHFONBZMPXFSUIFUFTUSFTVMU

Performance Characteristics :

1), 2), 3)

The performance of the Glucose Test Strips has been evaluated in laboratory. 

Measurement Range:

 

5IFNFBTVSFNFOUSBOHFPGUIF(MVDFPöOF¥(MVDPTF5FTUJOHJTUPNHE- NNPM-

Accuracy:

 The accuracy results obtained with the Gluceofine® Blood Glucose Monitoring system were compared to 

HMVDPTFSFTVMUTPCUBJOFEXJUI)*5"$)*(MVDPTF"VUP"OBMZ[FSBMBCPSBUPSZJOTUSVNFOU(MVDPTFMFWFMTXFSF

NFBTVSFEPOQBUJFOUT

System accuracy results for glucose concentration <75 mg/dL (4.2 mmol/L)

System accuracy results for glucose concentration ≥75 mg/dL (4.2 mmol/L) 

Precision: 

- Repeatability Precision Test.

- Intermediate Precision Test

IMPORTANT:

t#FGPSFVTJOHUIF(MVDFPöOF¥NFUFSBOEHMVDPTFUFTUTUSJQTSFBEBMMPGUIFPQFSBUJOHJOTUSVDUJPOTJOUIFPXOFShT

manual.

t$POTVMUZPVSQIZTJDJBOPSEJBCFUJDIFBMUIDBSFQSPGFTTJPOBMBCPVUEBJMZNBOBHFNFOUPGZPVSEJBCFUFTBOEQSPQFS

use of the glucometer.

t1MFBTFCFWFSZDBSFGVMXIJMFIBOEMJOHCMPPE$BSFMFTTOFTTDBOIBWFTFSJPVTDPOTFRVFODFTGPSZPVSIFBMUI%JTDBSE

used test strips properly, to avoid any infection.

t*GZPVIBWFBOZRVFTUJPOTBCPVUVTFPGUIFQSPEVDUTQMFBTFDPOUBDU.FUSBEP(NC)PSZPVSMPDBMSFQSFTFOUBUJWF

063$0..*5.&/550:06

We understand that blood glucose levels provide a way to control your diabetes. As a result, the Gluceofine® 

Testing System was developed to help you manage your diabetes by the most comfortable and convenient way 

possible. Our goal, at Infopia is to provide you the best quality products and superior customer service. If you have 

any questions or comments, please contact Metrado GmbH or your local representative. 

/PUF1SJDLJOHUIFTJEFPGZPVSöOHFSUJQJTMFTTQBJOGVM%POPUTRVFF[FPSNJMLUIFQVODUVSFTJUF

IMPORTANT NOTE: Blood glucose may be altered by your food, physical activity, and/or stress.

Within ±  5mg/dL

(within ± 0.28 mmol/L)

8JUIJOœNHE-

(within ± 0.56 mmol/L)

8JUIJOœNHE-

(within ± 0.83 mmol/L)

 

 

 

8JUIJOœ

8JUIJOœ

8JUIJOœ

 

 

 

8JUIJOœ

 

Mean (mg/dL)

228.2

362.0

SD

$7

2.8

2.2

2.8

Mean (mg/dL)

SD

$7

3.0

2.5

Correct

Completely Filled

Incorrect

Poorly filled

"QQMZZPVSCMPPEUPUIFHMVDPTFUFTUTUSJQBOEEPOPUUBLFPòZPVSöOHFSVOUJMZPVHFUUIFCFFQTPVOE5IFUFTUXJMM

automatically start.

    

     NOTE : Please refer to the table below to identify symbol

Range of Expected Values :

Self testing of blood glucose levels provides a way to control your diabetes. Consult with your physician to determine 

UIFCFTUSBOHFPGFYQFDUFECMPPEHMVDPTFWBMVFTGPSZPV

5IFGBTUJOHBEVMUCMPPEHMVDPTFSBOHFGPSBQFSTPOXJUIPVUEJBCFUFTJTMFTTUIBONHE-PSNNPM-5XPIPVST

BGUFSNFBMTOPSNBMHMVDPTFMFWFMTTIPVMECFMFTTUIBONHE-PSNNPM-

"NFSJDBO%JBCFUFT"TTPDJBUJPO%JBCFUFT$BSF7PMVNF4VQBOVBSZQ44

  IMPORTANT: 

*GZPVIBWFBUFTUSFTVMUCFMPXNHE- NNPM-PSPWFSNHE- NNPM-DPOUBDUZPVSEPDUPSJNNFEJ-

ately. If your blood glucose result is unusually low or high, repeat the test again with a new glucose test strip. If the 

SFTVMUTBSFTUJMMJODPOTJTUFOUQMFBTFDPOTVMUZPVSQIZTJDJBOCFGPSFNBLJOHBOZEFDJTJPOUPDPOUSPMZPVSEJBCFUFT

Quality Control (System Maintenance) :

Gluceofine®(MVDPTF$POUSPM4PMVUJPOJTVTFEUPDIFDLUIBUUIFNFUFSBOEHMVDPTFUFTUTUSJQTBSFQSPQFSMZXPSLJOH

together to provide you with the most accurate reading.

Note:

  

The Gluceofine® Glucose Control Solutions is sold separately. The normal, and high level glucose control solutions 

can be obtained through your pharmacy, Metrado GmbH or your local representative.

Gluceofine® Glucose Control Solution test can only be used with the Gluceofine® meter and should be used 

during the following:

t8IFOBOFXWJBMPGHMVDPTFUFTUTUSJQTJTPQFOFE

t"OZTVTQJDJPOUIBUUIFNFUFSPSHMVDPTFUFTUTUSJQTBSFOPUXPSLJOHQSPQFSMZ

t8IFOZPVSCMPPEHMVDPTFUFTUSFTVMUTBSFOPUDPOTJTUFOUXJUIZPVSTZNQUPNTPSJGZPVUIJOLUIFZBSFOPUBDDVSBUF

t*GZPVESPQUIFHMVDPTFUFTUNFUFS

t6TFSPVUJOFMZUPPCUBJOBDDVSBUFSFTVMU

6TFE#Z

Consult Instructions for use

This product fulfills the requirements of Directive 
&$POJOWJUSPEJBHOPTUJDNFEJDBMEFWJDFT

Attention, see instructions for use

Catalogue Number

*O7JUSP%JBHOPTUJDT.FEJDBM%FWJDF

Batch code

Temperature limitation

Date of Manufacture

Do not re-use

For Self-testing

Manufacturer

('4..533FW

METRADO GmbH

"VG1GVIMTU%.FSDIXFJMFS
GERMANY
5FM 
'BY
www.metrado.de

Discard 3 months after opening

3 M

Correct

 Incorrect

Applying Blood

0483

1;/

Blutzucker-Teststreifen

8*$)5*(#FWPS4JFEJF5FTUTUSFJGFOCFOVU[FOMFTFO4JFEJFTF1BDLVOHTCFJMBHFVOEEJF#FEJFOVOHTBOMFJUVOHMISFT
(MVDFPöOF¥#MVU[VDLFS.FTTHFSÊUFT

Verwendungszweck:

(MVDFPöOF¥#MVU[VDLFS5FTUTUSFJGFOTJOE[VS4FMCTUBOXFOEVOHHFFJHOFUVOEXFSEFONJU(MVDFPöOF¥#MVU[VDLFS-

.FTT4ZTUFNFO [VS RVBOUJUBUJWFO #FTUJNNVOH EFT #MVU[VDLFSHFIBMUFT JO LBQJMMBSFN7PMMCMVU CFOVU[U 6N FJOFO

FJOGBDIFO7FSHMFJDIEFS.FTTFSHFCOJTTFNJU-BCPSNFUIPEFO[VFSNÚHMJDIFOTJOE(MVDFPöOF¥4ZTUFNFQMBTNBLBMJ-

CSJFSU%JF(MVDFPöOF¥5FTUTUSFJGFOTJOEOVS[VN(FCSBVDIBV•FSIBMCEFTNFOTDIMJDIFO,ÚSQFSTCFTUJNNU *OWJUSP-

%JBHOPTUJL%BT(MVDFPöOF¥#MVU[VDLFS.FTT4ZTUFNXVSEF[VS4FMCTUBOXFOEVOHFOUXJDLFMU

Allgemeines:

%JF(MVDFPöOF¥#MVU[VDLFS5FTUTUSFJGFOTJOENJUFJOFSOFVFOUXJDLFMUFO#JP4FOTPS5FDIOPMPHJFBVGFMFLUSPDIFNJTDIFS

#BTJT BVTHFTUBUUFU %BT HFSJOHF 1SPCFOWPMVNFO WPO OVS  ɅM FSNÚHMJDIU [VEFN TDINFS[GSFJFSFT .FTTFO

(MVDFPöOF¥.FTT4ZTUFNFLÚOOFOCJT[V.FTTXFSUFNJU%BUVNVOE6IS[FJUTQFJDIFSO%JF&SHFCOJTTFLÚOOFO

BVGEFO1$àCFSUSBHFOXFSEFO PQUJPOBM%JFTFSNÚHMJDIUFJOFFJOGBDIFSFVOECFTTFSF,POUSPMMF*ISFT#MVU[VDLFST

Lagerung und Handhabung:

-BHFSO4JFEJF3ÚISDIFONJUEFO(MVDFPöOF¥5FTUTUSFJGFOBOFJOFNUSPDLFOFO0SU[XJTDIFO¡$VOE¡$4FU[FO4JF

EJF5FTUTUSFJGFOOJFEJSFLUFN4POOFOMJDIUBVTVOEMBHFSO4JFEJFTFOJDIUJN,àIMPEFS(FGSJFSTDISBOL

#FXBISFO4JFEJF5FTUTUSFJGFOOVSJOEFOEB[VHFIÚSFOEFO3ÚISDIFOBVGVOENJTDIFO4JFOJFNBMT5FTUTUSFJGFOBVT

VOUFSTDIJFEMJDIFO1BDLVOHFOJOFJOFN3ÚISDIFO

7FSTDIMJF•FO4JFEBT3ÚISDIFOOBDI&OUOBINFEFT5FTUTUSFJGFOTVNHFIFOE%SàDLFO4JFEB[VEFO%FDLFMGFTUBVGEBT

3ÚISDIFO

Benutzen Sie den Teststreifen sofort nach der Entnahme.

6NGBMTDIF.FTTFSHFCOJTTF[VWFSNFJEFOCFOVU[FO4JFEJF5FTUTUSFJGFOOJDIUOBDIEFNBVGHFESVDLUFO7FSGBMMTEB-

UVNBVG1BDLVOHVOE3ÚISDIFO

7FSCSBVDIFO4JFEJF5FTUTUSFJGFOFJOFT3ÚISDIFOTJOOFSIBMCWPOESFJ.POBUFOOBDI"OCSVDI/PUJFSFO4JFTJDIEBT

&OUTPSHVOHTEBUVN 5BHEFT"OCSVDITQMVT.POBUFBVGEFN5FTUTUSFJGFOSÚISDIFO

7FSNFJEFO4JFEFO,POUBLUEFS5FTUTUSFJGFONJU4DINVU[-FCFOTNJUUFMOPEFS8BTTFS'BTTFO4JFEJF5FTUTUSFJGFOOJDIU

NJUOBTTFO)ÊOEFOBO

#JFHFOPEFSTDIOFJEFO4JFEJF5FTUTUSFJGFOOJDIU/FINFO4JFBVDITPOTULFJOF7FSÊOEFSVOHFOBOJIOFOWPS

"DIUFO4JFEBSBVGEJF'BSCNBSLJFSVOHBVGEFN5FTUTUSFJGFOOJDIU[VWFSTDINVU[FO

Gluceofine®-Teststreifen sind nur zum einmaligen Gebrauch bestimmt.

/FINFO4JFLFJOF#MVU[VDLFSNFTTVOHFOVOUFSIBMCFJOFS5FNQFSBUVSWPO¡$C[XPCFSIBMCFJOFS5FNQFSBUVSWPO

¡$WPSFCFOTPOJDIUVOUFSIBMCFJOFS-VGUGFVDIUJHLFJUWPOC[XPCFSIBMCFJOFS-VGUGFVDIUJHLFJUWPO

%JF5FTUTUSFJGFOEàSGFOOJDIUJOEJF)ÊOEFWPO,JOEFSOHFMBOHFO

&OUTPSHFO4JFEFO5FTUTUSFJGFOTPSHTBNVNFJOF*OGFLUJPO[VWFSNFJEFO

"DIUVOH#FOVU[FO4JF(MVDFPöOF¥#MVU[VDLFS5FTUTUSFJGFOOVSNJU(MVDFPöOF¥#MVU[VDLFS.FTTHFSÊUFO

Wichtige Hinweise:

7FSXFOEFO4JFKFEFO5FTUTUSFJGFOOVSFJONBM&JOFNFISGBDIF7FSXFOEVOHGàISU[VGBMTDIFO.FTTFSHFCOJTTFO

#FNFSLFO 4JF 4ZNQUPNF EJF TJDI BVDI CFJ SJDIUJHFS "OXFOEVOH EFT (FSÊUFT OJDIU NJU EFO HFNFTTFOFO

#MVU[VDLFSXFSUFOEFDLFOLPOUBLUJFSFO4JFCJUUF*ISFO"S[U

7FSÊOEFSO4JFOJDIUTFMCTUÊOEJH*ISFO5FTUPEFS.FEJLBUJPOTQMBO

*HOPSJFSFO4JFLFJOFLÚSQFSMJDIFO4ZNQUPNFLPOUBLUJFSFO4JF*ISFO"S[U

Messprinzip:

%JF#MVUQSPCFXJSEEVSDI,BQJMMBSLSÊGUFJOEJF4QJU[FEFT5FTUTUSFJGFOTHFTBVHU%JF(MVLPTFJOEFS#MVUQSPCFSFBHJFSU

NJUEFN&O[ZN(MVDPTF0YJEBTFBVGEFN5FTUTUSFJGFO%BCFJFOUTUFIUFJOVOHFGÊISMJDIFSFMFLUSJTDIFS(MFJDITUSPN

%JFTFSXJSEWPN(FSÊUHFNFTTFOVOEEBTBOHF[FJHUF.FTTFSHFCOJTEBSBVTBCHFMFJUFU

Zusammensetzung der Reagenzien (Jeder Gluceofine®-Teststreifen enthält):

(MVDPTF0YJEBTF "TQFSHJMMVTOJHFS

&JOIFJUFO

.FEJBUPS )FYBBNNJOFSVUIFOJVNDIMPSJEF

#JOEFNJUUFM

4UBCJMJTBUPS

Ablauf der Blutzucker-Messung:

#FOÚUJHU XFSEFO (MVDFPöOF¥ #MVU[VDLFS5FTUTUSFJGFO CFOÚUJHU BCFS OJDIU JN -JFGFSVNGBOH FOUIBMUFO

(MVDFPöOF¥#MVU[VDLFS.FTTHFSÊU#FEJFOVOHTBOMFJUVOH4UFDIIJMGFTUFSJMF-BO[FUUF

Gewinnung der Blutprobe: 

(MVDFPöOF¥#MVU[VDLFS5FTUTUSFJGFOEàSGFOOVSNJUGSJTDIFNLBQJMMBSFN7PMMCMVU[VN&JOTBU[LPNNFO&OUOFINFO4JFEJF

#MVUQSPCFBVTFJOFS'JOHFSCFFSFPEFSFJOFSBOEFSFOHFFJHOFUFO,ÚSQFSTUFMMF TJFIF#FOVU[FSIBOECVDI[VN.FTTHFSÊU

Um einen Tropfen Blut zu erhalten, beachten Sie folgende Schritte:

t

t

t

t

t

t

t

t

t

t

t

t

t

t

t

t

t

Schritt 1: Sauberkeit 

8BTDIFO4JF*ISF)ÊOEFHSàOEMJDINJUXBSNFN8BTTFSVOE

USPDLOFO4JFTJFHVUBC7PSEFS1SPCFOHFXJOOVOHNVTTEJF'JOHFSCFFSFBCTPMVU

USPDLFOVOETBVCFSTFJO "VDI4DINVU[PEFS4DIXFJ•CFFJOøVTTFOEBT.FTTFSHFC-

nis.)

Schritt 2: Vorbereiten der Stechhilfe 

Bereiten Sie die Stechhilfe und Lanzette vor. 

Führen Sie eine unbenutzte Lanzette in die Stechhilfe ein. Die Stechhilfe ist eine 

TUJGUBSUJHF7PSSJDIUVOH[VS"VGOBINFEFS-BO[FUUF4JFCFJOIBMUFUVOEQPTJUJPOJFSU

CFJN4UFDIFOEJF-BO[FUUF%JF5JFGFEFT&JOTUJDITLBOOBOEFS4UFDIIJMGFFJOHFTUFMMU

XFSEFO  /ÊIFSF *OGPSNBUJPOFO öOEFO 4JF JO EFS #FEJFOVOHTBOMFJUVOH EFT

(MVDFPöOF¥#MVU[VDLFS.FTTHFSÊUFT

Schritt 3: Einführen des Teststreifens

&OUOFINFO4JFFJOFO5FTUTUSFJGFOBVTEFN3ÚISDIFO7FSTDIMJF•FO4JFEBT3ÚISDIFO

VNHFIFOEXJFEFSVNEBT&JOESJOHFOWPO'FVDIUJHLFJU[VWFSNFJEFO'àISFO4JF

EFO5FTUTUSFJGFOTPJOEJF(FSÊUFÚòOVOHFJOEBTTEJFNJUEFN1GFJMHFLFOO[FJDIOFUF

4FJUFOBDIPCFOVOE[VN(FSÊUIJO[FJHU%BT(FSÊUTDIBMUFUTJDIFJOVOEFSLFOOU

automatisch  die  Teststreifen-Codierung.  Überprüfen  Sie,  ob  die  angezeigte 

$PEJFSVOHNJUEFSEFT5FTUSÚISDIFOTàCFSFJOTUJNNU*TUEJFTOJDIUEFS'BMMXJFEFSIP-

MFO4JFEFO7PSHBOH"OTDIMJF•FOECMJOLUEBT4ZNCPM[VN"VGUSBHFOEFS#MVUQSPCF

VOEEBT(FSÊUJTUNFTTCFSFJU

Schritt 4: Gewinnen und Auftragen der Blutprobe

Stechen Sie mit der Stechhilfe in die vorgesehene Stelle z.B. in die Fingerbeere. Für ein 

LPSSFLUFT .FTTFSHFCOJT XJSE FJO 1SPCFOWPMVNFO WPO NJOEFTUFOT ɅM CFOÚUJHU

8ÊISFOEEBT4ZNCPM[VN"VGUSBHFOJOEFS"O[FJHFCMJOLUIBMUFO4JFEFO'JOHFSNJUEFN

#MVUTUSPQGFOTFJUMJDIBOEBTTDINBMF&OEFEFT5FTUTUSFJGFOTCJTEBTJGÚSNJHF5FTUGFOTUFS

BVGEFN5FTUTUSFJGFOLPNQMFUUNJU#MVUHFGàMMUJTU%SàDLFO4JFEFO'JOHFSOJDIUHFHFOEBT

5FTUTUSFJGFOFOEF7FSTVDIFO4JFOJDIUEJF#MVUQSPCFBN5FTUTUSFJGFOBC[VTUSFJGFO&JO

#FTUÊUJHVOHTUPOTJHOBMJTJFSU*IOFOXFOOBVTSFJDIFOE#MVUBVGHFUSBHFOXVSEF#FJ[V

HFSJOHFS#MVUNFOHF/FVF.FTTVOHNJU/&6&.5FTUTUSFJGFOEVSDIGàISFO

Schritt 5: Messergebnis in 5 Sekunden

%BT(FSÊUTUBSUFUEJF.FTTVOHBVUPNBUJTDI/BDIFJOFN4FLVOEFO$PVOUEPXOXJSE

das  Ergebnis  angezeigt  und  automatisch  gespeichert.  (Zur  Mitspeicherung  von 

#FOVU[FS"LUJWJUÊUFOVOE#FOVU[FS*%TJFIF)BOECVDIEFT.FTTHFSÊUFT#FOVU[FO4JF

den  Teststreifenauswurf,  um  den  Teststreifen  zu  entfernen.  Nach  Beendigung  der 

.FTTVOHTDIBMUFUEBT(FSÊUBVUPNBUJTDIBC

5JQQ4UFDIFO4JFJOEJFTFJUMJDIF'JOHFSCFFSF%BTJTUXFOJHFSTDINFS[IBGUBMTNJUUJH[VTUFDIFO6NFJOHFOBVFT

.FTTFSHFCOJT[VFSIBMUFOQVOLUJFSUF4UFMMFOJDIUOBDIRVFUTDIFOTPOEFSOWPSEFN4UFDIFONBTTJFSFO

Wichtige Information zu an anderen Körperstellen gewonnenen Blutproben:

"MUFSOBUJWF.FTTQVOLUFTJOE)BOEøÊDIF)BOESàDLFO6OUFSBSN0CFSBSN8BEFVOE0CFSTDIFOLFM

.FTTFSHFCOJTTFBVT#MVUQSPCFOFJOFT'JOHFSTVOEBVTBOBOEFSFO,ÚSQFSTUFMMFOHFXPOOFOFO#MVUQSPCFOLÚOOFO

TUBSLWPOFJOBOEFSBCXFJDIFO

%JF#MVU[VDLFSLPO[FOUSBUJPOJOEFS'JOHFSTQJU[FWFSÊOEFSUTJDITDIOFMMFSBMTJN3FTUEFT,ÚSQFST

&JOF.FTTVOHBOEFS'JOHFSTQJU[FLBOOTDIOFMMFSFJOF)ZQPHMZLÊNJF 6OUFS[VDLFSBVDIBMT3FBLUJPOBVG*OTVMJOHB-

CF NÚHMJDI OBDIXFJTFO BMT FJOF .FTTVOH NJU FJOFS #MVUQSPCF WPO BOEFSFO ,ÚSQFSTUFMMFO #FJ 7FSEBDIU BVG

)ZQPHMZLÊNJFOVU[FO4JFCJUUFHFOFSFMM#MVUQSPCFOBVTEFS'JOHFSTQJU[F

.FTTVOHFONJU#MVUQSPCFOWPOBOEFSFO,ÚSQFSTUFMMFOTPMMUFONJOE4UVOEFOOBDIEFSMFU[UFO.BIM[FJULÚSQFSMJ

DIFS#FUÊUJHVOHPEFSKFHMJDIFNBOEFSFO&SFJHOJTEBT*ISFO#MVU[VDLFSXFSUCFFJOøVTTUEVSDIHFGàISUXFSEFO

#FJLàS[FSFO"CTUÊOEFOWFSXFOEFO4JFCJUUFJNNFS#MVUBVTEFS'JOHFSTQJU[F

%JFTHJMUCFTPOEFSTJN3BINFOWPO"VUPGBISUFOPEFSXFOO4JF[VEFS(SVQQFWPO%JBCFUJLFSOHFIÚSFOCFJEFOFO

TJDI LFJOF UZQJTDIFO 4ZNQUPNF FJOFT IZQPHMZLÊNJTDIFO ;VTUBOEFT  6OUFS[VDLFSVOH [FJHFO )JFS LBOO EVSDI

.FTTVOHBOBOEFSFO,ÚSQFSTUFMMFOV6FJOF)ZQPHMZLÊNJFOJDIUFOUEFDLUXFSEFO

Messergebnisse

%JF.FTTFSHFCOJTTFXFSEFOKFOBDI*ISFS&JOTUFMMVOHBN(FSÊUFOUXFEFSJONHE-PEFSNNPM-BOHF[FJHU%FS

.FTTCFSFJDIEFT(MVDFPöOF¥.FTTHFSÊUFTMJFHU[XJTDIFOVOENHE- NNPM-

-JFHUEFSHFNFTTFOF8FSUVOUFSIBMCWPONHE- NNPM-FSTDIFJOUi-PwJOEFS"O[FJHFi-PwCFEFVUFUTDIXFSF)ZQPHMZ

LÊNJF  6OUFS[VDLFS -JFHU EFS HFNFTTFOF8FSU PCFSIBMC WPO NHE-  NNPM- FSTDIFJOUi)*w JO EFS "O[FJHFi)*w

CFEFVUFUTDIXFSF)ZQFSHMZLÊNJF ÃCFS[VDLFS#FHFCFO4JFTJDIJOCFJEFO'ÊMMFOVNHFIFOEJONFEJ[JOJTDIF#FIBOEMVOH

8JDIUJH.BIM[FJUFOLÚSQFSMJDIF"LUJWJUÊUFOVOEBOEFSF&JOøàTTFXJSLFOTJDIBVG*ISFO#MVU[VDLFSXFSUBVT

Bandbreite von Messwerten:

4FMCTUÊOEJHFT.FTTFO*ISFT#MVU[VDLFSTIJMGU*IOFO*ISFO%JBCFUFT[VLPOUSPMMJFSFO,POTVMUJFSFO4JF*ISFO"S[UVN

*ISFOJOEJWJEVFMMFO;JFMCFSFJDIEFT#MVU[VDLFSXFSUFTGFTU[VTUFMMFO&SXBSUFUF.FTTXFSUFGàS.FOTDIFOPIOF%JBCFUFT

/àDIUFSOWPSEFN&TTFONHE- NNPM-4UVOEFOOBDIEFN&TTFONHE- NNPM-

"NFSJDBO%JBCFUFT"TTPDJBUJPO%JBHOPTJTBOE$MBTTJöDBUJPOPG%JBCFUFT.FMMJUVT 1PTJUJPO4UBUFNFOU%JBCFUFT$BSF 4VQQMFNFOU4

Wichtig:

#FJ .FTTFSHFCOJTTFO VOUFS  NHE-   NNPM- C[X àCFS  NHE-   NNPM- LPOUBLUJFSFO 4JF CJUUF

VNHFIFOE*ISFO"S[U*TUEBT&SHFCOJTVOHFXÚIOMJDIIPDIPEFSOJFESJHPEFSIBMUFO4JFEBT&SHFCOJTGàSGBMTDI

GàISFO4JFCJUUFFJOFFSOFVUF.FTTVOHEVSDI*TUEBT&SHFCOJTXFJUFSIJOOJDIU[VGSJFEFOTUFMMFOELPOUBLUJFSFO4JF

CJUUF*ISFO"S[UCFWPS4JFTFMCTU*ISFO.FEJLBUJPOTPEFS5FTUQMBOÊOEFSO

'VOLUJPOTLPOUSPMMFEFT4ZTUFNT

.JUEFS(MVDFPöOF¥,POUSPMM-ÚTVOHàCFSQSàGFO4JFPCEBT.FTTHFSÊUVOEEJF5FTUTUSFJGFOBMT&JOIFJUGVOLUJPOJFSFO

und Ihnen genaue Messergebnisse liefern.

Hinweis:

%JF(MVDFPöOF¥,POUSPMM-ÚTVOHJTUTFQBSBUFSIÊMUMJDI,POUSPMM-ÚTVOHFOJNOPSNBMFOVOEIPIFO#FSFJDIFSIBMUFO

4JFJOMISFS"QPUIFLFCFJEFS.FUSBEP(NC)PEFSEFN7FSUSJFCTQBSUOFSJO*ISFN-BOE

t

t

t

t

t

t

%JF,POUSPMM-ÚTVOHEBSGOVSNJU(MVDFPöOF¥.FTTHFSÊUFOWFSXFOEFUXFSEFO&JOF"OXFOEVOHJTUTJOOWPMM

XFOO4JFFJOFOFVF1BDLVOH5FTUTUSFJGFOWFSXFOEFO

XFOO4JFWFSNVUFOEBTT(FSÊUPEFS5FTUTUSFJGFOOJDIUFJOXBOEGSFJGVOLUJPOJFSFO

XFOO*ISF.FTTFSHFCOJTTFTJDIOJDIUNJU*ISFO4ZNQUPNFOEFDLFOPEFS4JFGBMTDIF.FTTFSHFCOJTTFWFSNVUFO

XFOO*IOFOEBT(FSÊUIFSVOUFSHFGBMMFOJTU

[VSSPVUJOFNʕJHFOÃCFSQSàGVOHEFS5FTUSFTVMUBUF

8FOO4JFEJF,POUSPMM-ÚTVOH BOBMPHFJOFT#MVUTUSPQGFOTBN&OEFEFT5FTUTUSFJGFOTBVGUSBHFOTPMMUFOEJF&SHFCOJT-

TFJOOFSIBMCEFTBVGEFN5FTUTUSFJGFOSÚISDIFOBVGHFESVDLUFO#FSFJDIFTMJFHFO-JFHUEBT&SHFCOJTBV•FSIBMCEJFTFT

Bereiches, wiederholen Sie bitte die Messung mit einem neuen Teststreifen.

.FTTFSHFCOJTTFBV•FSIBMCEFT#FSFJDIFTLÚOOFOGPMHFOEF6STBDIFOIBCFO

Fehler in der Durchführung der Messung.

6OHFOàHFOEFT4DIàUUFMOEFT'MÊTDIDIFOTWPSEFN"VGUSBHFO LSÊGUJHFT4DIàUUFMOJTUOPUXFOEJH

7FSXFOEVOHEFTFSTUFO5SPQGFOT,POUSPMM-ÚTVOH %FOFSTUFO5SPQGFOCJUUFJNNFSFOUTPSHFO

"CHFMBVGFOFPEFSWFSVOSFJOJHUF,POUSPMM-ÚTVOH

#FTDIÊEJHUFS5FTUTUSFJGFO

'FIMGVOLUJPOEFT(FSÊUFT

&JOF OJDIU BVTSFJDIFOEF "OQBTTVOH WPO ,POUSPMM-ÚTVOH 5FTUTUSFJGFO VOEPEFS (FSÊU BO EFO FNQGPIMFOFO

Temperaturbereich (20-25 °C).

8*$)5*(8FOOEJF.FTTFSHFCOJTTFNJUEFS,POUSPMM-ÚTVOHGPSUXÊISFOEBV•FSIBMCEFTBVGEFN3ÚISDIFOBOHFHFCF-

OFO#FSFJDIFTMJFHFOLÚOOUFEBT(MVDFPöOF¥4ZTUFNOJDIUSJDIUJHGVOLUJPOJFSFO#FOVU[FO4JFEBT4ZTUFNOJDIU[VS

#MVU[VDLFS.FTTVOHCJT4JFNJUEFS,POUSPMM-ÚTVOH&SHFCOJTTFJOOFSIBMCEFTBOHFHFCFOFO#FSFJDIFTFSIBMUFO#JUUF

LPOUBLUJFSFO4JFCFJGPSUXÊISFOEFO1SPCMFNFOEJF.FUSBEP(NC)PEFSEFO7FSUJFCTQBSUOFSJO*ISFN-BOE

Grenzen des Systems:

Mit den Gluceofine®-Teststreifen erhalten Sie genaue Messergebnisse, wenn Sie die nachfolgenden Dinge beachten:

7FSXFOEFO4JFLFJOF#MVUQSPCFOWPO/FVHFCPSFOFO

7FSXFOEFO4JF[VS.FTTVOHOVSGSJTDIFTLBQJMMBSFT7PMMCMVU#FOVU[FO4JFLFJO1MBTNBPEFS4FSVN

%FIZESBUJPO 'MàTTJHLFJUTNBOHFMLBOOEBT.FTTFSHFCOJTCFFJOøVTTFO4PMMUFO4JFTFISEFIZESJFSUTFJOLPOUBLUJF-

ren Sie bitte  umgehend Ihren Arzt.

%JF5FTUTUSFJGFOTJOEBVTTDIMJF•MJDI[VNFJONBMJHFO(FCSBVDIHFFJHOFU7FSXFOEFO4JFTJFOJDIUNFISNBMT

6OHFOBVF.FTTFSHFCOJTTFLÚOOFOVOUFS4DIPDLCFJ#MVUIPDIESVDLQBUJFOUFOJOIZQFSHMZLÊNJTDIFNPEFS

hyperosmolarem Zustand mit oder ohne Ausscheidung von Ketonen auftreten.

(MVDFPöOF¥5FTUTUSFJGFOLÚOOFOPIOF#FFJOUSÊDIUJHVOHJOCJTCJT[VN)ÚIFWFSXFOEFUXFSEFO

Ärzte und medizinisches Fachpersonal beachten bitte die nachfolgend aufgeführten Wechselwirkungen, die 

das Messergebnis beeinflussen können:

&YUSFNF )ÊNBUPLSJUXFSUF LÚOOFO EBT .FTTFSHFCOJT CFFJOøVTTFO )ÊNBUPLSJUXFSUF VOUFSIBMC  LÚOOFO [V

IPIFPCFSIBMC[VOJFESJHF.FTTFSHFCOJTTF[VS'PMHFIBCFO

8FDITFMXJSLVOHFO1BSBDFUBNPM)BSOTÊVSF"TDPSCJOTÊVSF 7JUBNJO$VOEBOEFSFSFEV[JFSFOEF4VCTUBO[FOIBCFO

JOOPSNBMFOUIFSBQFVUJTDIFO,PO[FOUSBUJPOFOJN#MVULFJOFOTJHOJöLBOUFO&JOøVTTBVGEBTKFXFJMJHF.FTTFSHFCOJT

*OTFISIPIFO,PO[FOUSBUJPOFOLÚOOFOTJFKFEPDIVOHFOBVFIÚIFSF.FTTFSHFCOJTTF[VS'PMHFIBCFO

'FUUSFJDIF#MVUQSPCFO,FJOFOTJHOJöLBOUFO&JOøVTTBVGEBT.FTTFSHFCOJTIBCFO$IPMFTUFSPM CJTNHE-PEFS

5SJHMZDFSJEF CJTNHE-#FJ1FSTPOFONJU8FSUFOBV•FSIBMCEJFTFT#FSFJDIFTTPMMUFOEJF(MVLPTFXFSUFNJU

besonderer Beachtung ausgewertet werden.

#MVUQSPCFONJUFJOFNIPIFO"OUFJMBO4BVFSTUPòLÚOOFOEBT.FTTFSHFCOJTWFSSJOHFSO

Leistungscharakteristika:

%JF-FJTUVOHEFS(MVDFPöOF¥5FTUTUSFJGFOJTUEVSDI-BCPSVOELMJOJTDIF5FTUTFWBMVJFSU

Messbereich: 

%FS.FTTCFSFJDIEFS(MVDFPöOF¥5FTUTUSFJGFOMJFHU[XJTDIFOVOENHE- NNPM-

Evaluierung der Systemleistung:

3JDIUJHLFJU%JF3JDIUJHLFJUEFS.FTTXFSUFEFT4ZTUFNTXVSEFJN7FSHMFJDINJUEFN)*5"$)*(MVDPTF"VUP"OBMZ[FS

FJOFN-BCPSJOTUSVNFOUàCFSQSàGU%JF.FTTXFSUFXVSEFOBVTGSJTDIFO,BQJMMBSCMVUQSPCFOFSNJUUFMU

Richtigkeit für Glukose-Konzentrationen <75 mg/dL (4,2 mmol/L)

Richtigkeit für Glukose-Konzentrationen >75 mg/dL (4,2 mmol/L)

Präzision:

t&SHFCOJTTF8JFEFSIPMQSÊ[JTJPO

t&SHFCOJTTF7FSHMFJDITQSÊ[JTPO

WICHTIG:

#JUUFMFTFO4JFGàSTJDIFSFTVOEHFOBVFT.FTTFOWPSEFN(FCSBVDIEFT(MVDFPöOF¥#MVU[VDLFS.FTTHFSÊUFTVOE

EFS5FTUTUSFJGFOVOCFEJOHUBVDITPSHGÊMUJHEBT#FOVU[FSIBOECVDI[VN.FTTHFSÊU

,POTVMUJFSFO4JFJN3BINFOEFS"OXFOEVOHEFT(MVDFPöOF¥(FSÊUFTVOE*ISFNUÊHMJDIFO%JBCFUFT.BOBHFNFOU

SFHFMNʕJH*ISFO"S[U

#JUUFTFJFO4JFJN6NHBOHNJU#MVUÊV•FSTUWPSTJDIUJH6OBDIUTBNLFJULBOOFSOTUIBGUFHFTVOEIFJUMJDIF'PMHFOOBDI

TJDI[JFIFO#FOVU[UF5FTUTUSFJGFOTJDIFSFOUTPSHFOVN*OGFLUJPOFO[VWFSNFJEFO

8FOO4JF'SBHFO[VN(FCSBVDIFJOFT(MVDFPöOF¥1SPEVLUFTIBCFOLPOUBLUJFSFO4JFCJUUFEJF.&53"%0(NC)

PEFSEFO7FSUSJFCTQBSUOFSJO*ISFN-BOE

Unser Engagement für Sie:

#MVU[VDLFS4FMCTULPOUSPMMFJTUJN3BINFOEFT%JBCFUFT.BOBHFNFOUTBVTHFTQSPDIFOXJDIUJH4JFLBOO*IOFO

4JDIFSIFJUJN6NHBOHNJU*ISFS,SBOLIFJUHFCFO.JUEJFTFN8JTTFOIBCFOXJSNJU(MVDFPöOF¥FJO#MVU[VDLFS-

.FTT4ZTUFNFOUXJDLFMUEBT*IOFOVOLPNQMJ[JFSUTDIOFMMFVOEHFOBVF.FTTFSHFCOJTTFMJFGFSU%FS.FTTWPSHBOH

JTU[VEFNTFISLPNGPSUBCFMVOEFJOGBDIEBEJF$PEJFSVOHBVUPNBUJTDIFSGPMHU

.JU (MVDFPöOF¥ FSIBMUFO 4JF FJO IPDIXFSUJHFT 2VBMJUÊUTQSPEVLU LPNCJOJFSU NJU VOTFSFN TFIS HVUFO 4FSWJDF

8FOO4JF'SBHFOPEFS"ONFSLVOHFO[V*ISFN(MVDFPöOF¥1SPEVLUIBCFOLPOUBLUJFSFO4JFCJUUF*ISFO"S[UPEFS

%JBCFUFTTQF[JBMJTUFOPEFSEFO)FSTUFMMFS ,POUBLUTJFIFVOUFO

t

t

t

t

t

t

t

t

t

t

t

t

t

t

t

t

t

t

t

t

t

t

t

t

t

t

t

Innerhalb ± 5mg/dL

(innerhalb ± 0.28 mmol/L)

*OOFSIBMCœNHE-

(innerhalb ± 0.56 mmol/L)

*OOFSIBMCœNHE-

(innerhalb ± 0.83 mmol/L)

25/26   )

26/26   )

26/26   )

 )

 )

 )

Innerhalb ±20

Innerhalb œ

Innerhalb œ

Innerhalb ±5

 )

Mittelwert (mg/dL)

2

6

2

228.2

362.0

SD

2.

2.

6.

6

$7  )

0

2.8

2.2

2.8

2.

Mittelwert (mg/dL)

30

SD

8

3.

6

$7  )

0

3.0

2.5

-FHFOEF6NEJFWFSXFOEFUFO4ZNCPMF[VJEFOUJö[JFSFOWFSXFOEFO4JFCJUUFOBDIGPMHFOEF"VGTUFMMVOH

Zu verbrauchen bis

Bitte beachten Sie die Gebrauchsanweisung!

%JFTFT1SPEVLUFSGàMMUEJF"OGPSEFSVOHFOEFS3JDIUMJOJF

&(àCFSMOWJUSP%JBHOPTUJLB

Achtung - Hinweise beachten!

"SUJLFMOVNNFS

*O7JUSP%JBHOPTUJLVN

Chargennummer

Lagerung bei (Temperaturbereich)

Herstellungsdatum

Zum Einmalgebrauch bestimmt

3 Monate nach dem Öffnen entsorgen

Hersteller

Zur Selbstanwendung geeignet

('4..533FW

     

METRADO GmbH

"VG1GVIMTU%.FSDIXFJMFS

GERMANY

5FM

'BY

www.metrado.de

Richtig

Blut auftragen

Falsch

Richtig

Falsch

Ausreichende Blutmenge

Zu geringe Blutmenge

5SBHFO4JFEBT#MVUBVGEFO#MVU[VDLFS5FTUTUSFJGFOBVGVOEIBMUFO4JF*ISFO'JOHFSTPMBOHFBOEFO5FTUTUSFJGFOCJT

FJO4JHOBMUPOFSUÚOU%JF.FTTVOHTUBSUFUBVUPNBUJTDI

3 M

0483

1;/

Reviews: