Metos OFTG 40B Operation Manual Download Page 2

10/31      Gas heated Fry-Tops and sloped Grillplates (FTG/BIG)

GB

INDEX

INSTALLATION INSTRUCTIONS

----------------------------------------------------------------------- page --- 11

WARNINGS

---------------------------------------------------------------------------------------------------------- page --- 11

INSTALLATION

------------------------------------------------------------------------------------------------------ page --- 11

Positioning
Assembly
In line union of the 600
Connection to gas piping

CONVERSION

 

TO

 

ANOTHER

 

TYPE

 

OF

 

GAS

------------------------------------------------------------------------ page --- 11

Replacement of burner nozzle
Burner primary air adjustment
Replacement of minimum adjustment screw
Replacement of pilot burner nozzle
Replacement of gas preset adhesive label

START

-

UP

------------------------------------------------------------------------------------------------------------ page --- 11

Function check
Nominal heat input check
Inlet pressure check

ANALYSIS

 

OF

 

SEVERAL

 

FAILURES

--------------------------------------------------------------------------------- page --- 11

Difficult or lacking pilot ignition
Extinction of pilot burner flame during operation
Extinction of main burner flame during operation
Difficult or lacking burner ignition
Difficult or lacking temperature adjustment

REPLACEMENT

 

OF

 

PARTS

 

SUBJECT

 

TO

 

CHANGE

----------------------------------------------------------------- page --- 12

Burner, Pilotburner, Thermocouple, Ignition spark plug, Safety thermostat
Gas valve, Piezoelectric igniter

USE AND MAINTENANCE

---------------------------------------------------------------------------------- page --- 12

WARNINGS

----------------------------------------------------------------------------------------------------------- page --- 12

Additional safety device

USE

------------------------------------------------------------------------------------------------------------------page --- 12

Burner ignition on appliances with firm splashguard
Burner ignition on appliances with removable splashguard
Burner extinction

CLEANING

 

AND

 

MAINTENANCE

------------------------------------------------------------------------------------ page --- 13

LIST

 

OF

 

PARTS

 

SUBJECT

 

TO

 

CHANGE

----------------------------------------------------------------------------- page --- 13

Summary of Contents for OFTG 40B

Page 1: ...GAS GRIDDLE OFTG 40B OFTG 40BLC OFTG 60B OFTG 60BLC Installation and Operation Manual...

Page 2: ...ure check ANALYSIS OF SEVERAL FAILURES page 11 Difficult or lacking pilot ignition Extinction of pilot burner flame during operation Extinction of main burner flame during operation Difficult or lacki...

Page 3: ...acking pilot ignition Insufficient gas inlet pressure Obstructed nozzle or main Defective gas cock INSTALLATION INSTRUCTIONS WARNINGS Installation adjustments and maintenance of the appliances must be...

Page 4: ...les or pans containing food on the plate The installation and adaptation to other types of gas must be done by qualified and authorized installers In case of breakdown close the gas cut off cock upstr...

Page 5: ...inse well and dry thoroughly Do not use iron scouring pads or chlorate products Do not use sharp objects which can scratch and ruin the steel surface Do not use corrosive products to clean the floor u...

Page 6: ......

Page 7: ......

Page 8: ...2x80 4x80 ugelli pilota 3 2x3 A mm 4 4 vite minimo 70 70 G30 G31 50 50 ugelli bruciatore 2x70 4x70 ugelli pilota 2 2x2 A mm 4 4 vite minimo 70 70 G110 8 ugelli bruciatore 2x290 4x290 ugelli pilota 1 2...

Page 9: ...31 G25 G30 G31 G20 G20 G30 G31 G30 G31 G20 G110 G120 G30 G31 G20 G25 1 G30 G31 G20 G25 1 G30 G31 G20 G30 G31 Category II 2H 3 II 2E 3 III 1a 2H 3B P II 1a 2H II 2ELL 3B P I 2L II 2H 3B P II 2H 3B P II...

Page 10: ...3 5 G25 DE 20 mbar kW 5 1 5 10 3 G30 29 mbar kW 5 1 9 10 3 8 G30 50 mbar kW 5 2 3 10 4 6 G110 8 mbar kW 5 2 1 10 4 2 G120 8 mbar kW 5 2 3 10 4 6 G20 25 mbar m3 h 0 53 0 18 1 06 0 37 G25 1 25 mbar m3 h...

Page 11: ...40 3 6 3 6 G 5 3 60 5 4 G 5 9 2 11 42 5 6 5 2 OFTG 40B OFTG 60B ASENNUSKUVA INSTALLATIONSBILD INSTALLATION DIAGRAM Mitat cm M tt cm Measurements cm G Kaasuliit nt Gasanslutning Gas connection ISO 7 1...