Parameter Default Description
MIN... MAX
Digital outputs
u1c
0
Relay configuration K1 configuration
0=compressor 1; 1=compressor 2; 3=evapo-
rator fans; 3=condensing fans; 4=defrosting;
5=cell light; 6=anti-fogging; 7=door ele-
ments; 8=neutral door elements; 9=drip tray
elements; 10=load 1 from button; 11=load 2
from button; 12=alarm; 13=on/stand-by
u2c
4
Relay configuration K2 configuration
0=compressor 1; 1=compressor 2; 2=evap-
orator fans; 3=condenser fans; 4=defrosting;
5=cell light; 6=anti-fogging; 7=door ele-
ments; 8=neutral zone element; 9=drip tray
element; 10=load 1 from button; 11=load 2
from button; 12=alarm; 13=on/stand-by
u3c
5
Relay configuration K3 configuration
0=compressor 1; 1=compressor 2; 2=evap-
orator fans; 3=condenser fans; 4=defrosting;
5=cell light; 6=anti-fogging; 7=door ele-
ments; 8=neutral zone element; 9=drip tray
element; 10=load 1 from button; 11=load 2
from button; 12=alarm; 13=on/stand-by
u4c
2
Relay configuration K4 configuration
0=compressor 1; 1=compressor 2; 2=evap-
orator fans; 3=condenser fans; 4=defrosting;
5=cell light; 6=anti-fogging; 7=door ele-
ments; 8=neutral zone element; 9=drip tray
element; 10=load 1 from button; 11=load 2
from button; 12=alarm; 13=on/stand-by
u5c
3
Relay configuration K5 configuration
0=compressor 1; 1=compressor 2; 2=evap-
orator fans; 3=condenser fans; 4=defrosting;
5=cell light; 6=anti-fogging; 7=door ele-
ments; 8=neutral zone element; 9=drip tray
element; 10=load 1 from button; 11=load 2
from button; 12=alarm; 13=on/stand-by
u2
0
Enable cell light and load from button in stand-by
0=no; 1=yes
in manual mode
u4
1
Enable alarm output muting
0=no; 1=yes
u5
-1.0
Door element threshold on
-99... 99 °C/°F
differential = 2°C/4°F
u6
5
Anti-fogging duration on
1... 120 min
u7
-5.0
Neutral zone threshold for heating ( in relation to set-
point)
-99... 99 °C/°F
differential = 2°C/4°F + se u7
u9
1
Enable alarm buzzer
0=no; 1=yes
Clock
Hr0
1
Enable clock
0=no; 1=yes
Energy saving (if r5=0)
HE2
0
Maximum energy saving duration
0... 999 min
Energy saving in real time (if r5=0)
H01
0
Energy saving time
0... 23 h
H02
0
Maximum energy saving duration
0... 24 h
Summary of Contents for 4247252
Page 27: ...Huomautuksia ...
Page 28: ......
Page 29: ...MANUAL GASTRONOMISKÅP EVJ SV MANUAL FÖR ANVÄNDNING OCH UNDERHÅLL GASTRONOMISKÅP EVJ ...
Page 55: ...Anmärkningar ...
Page 56: ......
Page 57: ...GASTRONOMY EVJ CABINET MANUAL EN USE AND MAINTENANCE MANUAL GASTRONOMY CABINET EVJ215 ...
Page 83: ......
Page 84: ...BN6LIBV003 ...