Water contains lime which remains on the surface
after the water has evaporated. These lime
deposits can be prevented from forming by wiping
immediately after use.
To clean the chrome-plated surfaces use a soft
cloth, soap and warm water. Never use cleaning
agents that contain a corrosive acid or a scouring
additive.
CLEANING
NOTE: Removal of the flow restrictor in the shower rose may be necessary to optimise flow performance in low or
unequal pressure systems only
Install a ½” male threaded connection at the desired
height on wall/or position on ceiling, ensuring that
a minimum of 10mm of thread protrudes past the
finished wall.
FOR WALL ARM - RECOMMENDED MINIMUM HEIGHT
2100MM FROM FLOOR LEVEL
Slide chrome trim ring onto the appropriate end of
the arm. Screw the arm onto the ½” connection using
plumbers tape or similar to ensure a reliable seal.
Position the arm vertically and push trim ring into
place.
Remove the protective cap from the showerhead ball
joint and screw the unit onto the wall/ceiling arm
ensuring the filter washer is in place.
Tilt and rotate the shower head to the desired position.
Ball Joint
Filter Washer
Vertical
Trim Ring
Arm
Min 10mm
Max
Ø 25mm
1.
2.
3.
4.
5.
NOTE - If assembling a showerhead to a pre-existing arm skip to step 4