1. 
2. 

3. 

4. 
5. 

6. 

7. 

8. 
9. 

10. 

Max. benchtop thickness 40mm. Cut a single 35mm diameter hole.
Insert o-ring provided into the groove in the bottom of the base ring. 

Unscrew 

mounting

 nuts and remove 

mounting

 plate, 

mounting

 gasket and one flexible inlet hose 

if necessary.
Place mixer   over hole ensuring that the o-ring remains in place.

Feed hose and 

mounting

 studs through the hole in the mounting surface.

Screw second hose into base of mixer if removed in step 3.

Slide 

mounting

 gasket and 

mounting

 plate onto 

mounting

 studs.

Position the mixer as desired.

Tighten mixer body to the mounting surface using the 

mounting

 nuts supplied.

Please Note: 

Make sure the o-ring in the base seals completely around the hole in the mounting surface.

Connect the ½” BSP Female hose fittings to the hot and cold supplies. Turn on the water supply 

and check carefully for leaks. Retighten joints if necessary.

IMPORTANT:

 Before you begin, turn off the water supply. It is recommended 

to fit isolation valves to both the hot and cold supply.

Installation: 

• 

• 

• 

• 

 

• 

 

 

• 

• 

• 

• 

 

IMPORTANT: 

Please read all of the 

instructions before installation.

General:

Methven recommends this product is installed 

by a licensed plumber in compliance with all 

relevant regional regulations. 

Do not hydrostatic test the installation with 

this mixer installed.  Damage to the ceramic 

cartridge may occur.

All pipe work must be thoroughly flushed prior 

to the installation of the mixer.

In-line filters must be fitted on both hot and 

cold supplies to prevent foreign particles 

damaging the ceramic cartridge.  

Do not remove the ceramic cartridge from the 

mixer when installing. 

After installation all connections must be 

checked for leaks.

All outlets used primarily for personal hygiene 

shall deliver water at a safe temperature as per 

regional regulations.

This mixer is not recommended for use in 

uncontrolled heating systems such as 

wet-backs or solar heating units unless a 

suitable tempering valve is fitted.

If limited water flow is experienced, locate 

aerator and filter washers and clean away 

foreign material as required.

It is the responsibility of the installer to ensure 

a waterproof seal is achieved between the 

product and mounting surface.  If in doubt 

about the quality of the seal, remove the 

product and reinstall.

Correct

Incorrect

Do not stretch or twist hose

DO NOT crush

Hose or swaged 

Ends

R35mm Min

20mm

• 

Flow restrictor

Valve

Low and Unequal pressure installation only: 

Unscrew aerator.  remove and replace aerator with flow straightener.

Unequal pressure installation only: 

Install Restrictor valve nipple to the cold inlet hose and adjust to balance hot and cold water flow.

Ferrule

Mounting Gasket

O-Ring

 

Mounting nuts

Flexible inlet hose:

cold 

hot

Mounting Studs

Mounting Plate

Remove Flow 

Resticted Aerator

Replace with 

Flow Straightener