3.3  METER SPECIFICATION

3MB100 

3.2 PERFORMANCE CRITERIA

Operating humidity              
Storage humidity                 
Operating temperature        
Storage temperature          
Humidity                                                    

International standard                                 
Accuracy class                                            
Protection against penetration of dust and water 

Insulating encased meter protective class

Connection area main terminals
Current terminals flexible 1×mm²                             

                            

 75%

 95%

-5°C to + 45°C (3K5)
-25°C to + 55°C (3k6)
75% yearly average
95% on 30 days per year
EN50470-3 & IEC62053-21
CI.1
IP51

0-16mm²
0 - 2.5mm² 
                            

Direct Connection

Current (A)

- Lref
- Ltr
- Lmax
- Lmin
- Ist

General data

Frequency (Hz) 
Memory back-up 

upper
lower

Pulse output

Pulse width(ms) 

Pulse Value =  1kWh

LED constant 
Width x Height x Depth (mm)

126 x 104.5 x 60

50/60

EEprom

Terminal 960  C

Cover 650  C

ABS+PC

400

80

400 PULSES

ABS+PC

100A

1A

0.5A

40mA

Environment resistance to 
heat and fire

3X230/400V

70%Un

Power consumption of current 
circuits (VA)
Power consumption of voltage 
circuits(W)

10A

< 0.01

< 1.3W

Voltage

4.  DIMENSIONS 

Summary of Contents for 3MB100

Page 1: ...g Memory back up EEprom 7 DIN module size METERSUK L T D 1 SAFETY NOTICE The smart energy meter 3 MB 100 does not require special mechanical or electrical tools for its installation Mounting position...

Page 2: ...C to 55 C 3k6 75 yearly average 95 on 30 days per year EN50470 3 IEC62053 21 CI 1 IP51 0 16mm 0 2 5mm Direct Connection Current A Lref Ltr Lmax Lmin Ist General data Frequency Hz Memory back up upper...

Page 3: ...10 24 17 12 19 14 21 9 23 16 11 18 13 20 1 3 5 7 2 4 6 LINE 1 IN LINE 1 OUT LINE 2 OUT LINE 3 OUT LINE 2 IN LINE 3 IN NEUTRAL IN 21 22 M Bus Communication 23 24 Pulse Output 23 24 Pulse Width 80m sec...

Page 4: ...the minimum bus voltage at any device must not be lower than 24 V 36 V 24 V 12 V The cable resistance therefore limits the maximum possible cable length from the MBus Master Repeater to the device wi...

Page 5: ...gy They are test pulse output pins 23 24 Usually the test pulse output is used as testing accuracy or reading purpose in close quarters passive transistor output requiring an external voltage source f...

Page 6: ...ue Press the SET button to save the digit and move onto the next digit 8 3 Baud rate setting Press SET button to bypass entering the Baud rate Press Down and Up buttons to select the communication bau...

Page 7: ...complete the meter will automatically save the password after 30 seconds or when powered off PLEASE NOTE It is important to take a note of the new password as one cannot bypass the system If the passw...

Reviews: