INDEX

1.   Safety notice
2.   Package Contents
3.   Technical Description
           3.1 Product Description
           3.2 Performance criteria
           3.3 Meter specification
4.   Dimensions           
5.   Wiring diagrams
6.   Meter reading
7.   Main features
           7.1 Consumption Indicator
           7.2 Reading the Meter
           7.3 Pulse Output
           7.4 Far Infrared Interface
           7.4 Communication Port
8   Programming
           8.1 Password verify
           8.2 CT Rate setting
           8.3 Baud rate setting
           8.4 ID/Address Setting
9.  Technical support

3.  TECHNICAL DESCRIPTION

3 MB 100   •   Direct Connection  •  M-Bus • Pulse output

D Y N A M i T E

Smart

Link

KEY FEATURES

•  Three Phase metering
•  Standard DIN rail format (DIN43880)
•  CI.1 Accuracy EN50470
•  LCD display, 6 integer 1 decimal
•  Large display LCD
•  Smart communication port, M-Bus output
•  Isolate pulse output and IR (DIN43864)
•  Direct metering up to 100A 
•  M-bus communication
•  Front Panel Programming
•  Memory back-up (EEprom)
•  7 DIN module size

METERS

UK

LTD

 1. SAFETY NOTICE

The smart energy meter 3 MB 100 does not require special mechanical 

or electrical tools for its installation.   Mounting position (with any angle of tilt) 

has no effect on the measurement functions of the meter.

Connection of the meter must follow the wiring diagram. 

Incorrect connection of the meter to the electricity network will cause a major 

display problem and can also cause serious damage to the meter. 

Before connecting the meter, ensure the local conditions of the energy supply 

is consistent with the information under the model number of the meter. 

Preferably use shielded cables. Make sure that all connection cables are 

not damaged during the installation of the meter and not energized or showing 

any non-mechanical stress.

Repairs to the meter are to be made by a qualified electrician only. 

PLEASE NOTE:  The capacitors in the meter may still be charged after the meter 

is disconnected for all power.

2. PACKAGE CONTENTS

Three phase, electronic energy meter 

Instructions for assembly; ID setting; Baud rate setting; 

Password setting

Summary of Contents for 3MB100

Page 1: ...g Memory back up EEprom 7 DIN module size METERSUK L T D 1 SAFETY NOTICE The smart energy meter 3 MB 100 does not require special mechanical or electrical tools for its installation Mounting position...

Page 2: ...C to 55 C 3k6 75 yearly average 95 on 30 days per year EN50470 3 IEC62053 21 CI 1 IP51 0 16mm 0 2 5mm Direct Connection Current A Lref Ltr Lmax Lmin Ist General data Frequency Hz Memory back up upper...

Page 3: ...10 24 17 12 19 14 21 9 23 16 11 18 13 20 1 3 5 7 2 4 6 LINE 1 IN LINE 1 OUT LINE 2 OUT LINE 3 OUT LINE 2 IN LINE 3 IN NEUTRAL IN 21 22 M Bus Communication 23 24 Pulse Output 23 24 Pulse Width 80m sec...

Page 4: ...the minimum bus voltage at any device must not be lower than 24 V 36 V 24 V 12 V The cable resistance therefore limits the maximum possible cable length from the MBus Master Repeater to the device wi...

Page 5: ...gy They are test pulse output pins 23 24 Usually the test pulse output is used as testing accuracy or reading purpose in close quarters passive transistor output requiring an external voltage source f...

Page 6: ...ue Press the SET button to save the digit and move onto the next digit 8 3 Baud rate setting Press SET button to bypass entering the Baud rate Press Down and Up buttons to select the communication bau...

Page 7: ...complete the meter will automatically save the password after 30 seconds or when powered off PLEASE NOTE It is important to take a note of the new password as one cannot bypass the system If the passw...