background image

6

Non-Warranty Repairs and Replacement – US and Canada

Non-warranty repairs in the United States and Canada should be sent to a
Meterman Test Tools Service Center. Call Meterman Test Tools or inquire at your
point of purchase for current repair and replacement rates.

In USA

In Canada

Meterman Test Tools

Meterman Test Tools

1420 75

th

 Street SW

400 Britannia Rd. E. Unit #1

Everett, WA  98203

Mississauga, ON L4Z 1X9

Tel: 800-993-5853

Tel: 905-890-7600

Fax: 425-446-6390

Fax: 905-890-6866

Non-Warranty Repairs and Replacement – Europe

European non-warranty units can be replaced by your Meterman Test Tools
distributor for a nominal charge. Please check the “Where to Buy” section on
www.metermantesttools.com for a list of distributors near you.

European Correspondence Address*

Meterman Test Tools Europe
P.O. Box 1186
5602 BD Eindhoven
The Netherlands

*

(Correspondence only – no repair or replacement available from this address.

European customers please contact your distributor.)

WARRANTY

The 30XR Digital Multimeter is warranted against any defects of material or
workmanship within a period of one (1) year following the date of purchase of the
multimeter by the original purchaser or original user.  Any multimeter claimed to be
defective during the warranty period should be returned with proof of purchase to
an authorized Meterman Test Tools Service Center or to the local Meterman Test
Tools dealer or distributor where your multimeter was purchased. See maintenance
section for details.  Any implied warranties arising out of the sale of a  Meterman
Test Tools multimeter, including but not limited to implied warranties of
merchantability and fitness for a particular purpose, are limited in duration to the
above stated one (1) year period.  Meterman Test Tools shall not be liable for loss
of use of the multimeter or other incidental or consequential damages, expenses, or
economical loss or for any claim or claims for such damage, expenses or
economical loss. Some states do not allow limitations on how long implied
warranties last or the exclusion or limitation of incidental or consequential
damages, so the above limitations or exclusions may not apply to you. This
warranty gives you specific legal rights, and you may also have other rights which
vary from state to state.

Summary of Contents for 30XR

Page 1: ...Britannia Rd E Unit 1 Mississauga ON L4Z 1X9 Tel 905 890 7600 Fax 905 89 6866 European Correspondence Address Meterman Test Tools Europe P O Box 1186 5602 BD Eindhoven The Netherlands Correspondence o...

Page 2: ...V HOLD 30XR MIN MAX NON CONTACT VOLTAGE V BATT 9V BATT 1 5V COM 10A mA V 600 600 200 200 200m 200m 20M 2M 20k 200k 2k 200 200m 20m 20 20 2 2 V A 10A 200 2m BATT OFF 2m 200m 200 20m A 10A 1 5V 9V MADE...

Page 3: ...d the maximum overload limits per function see specifications nor the limits marked on the instrument itself Never apply more than 600VDC between the test lead and earth ground Inspect DMM test leads...

Page 4: ...ce continuity and diode test Measuring DC Voltage See Figure 1 1 Set the Range Switch to an appropriate L range Select the highest range and work down if the voltage level is unknown 2 Connect the Tes...

Page 5: ...1 Set the Range Switch to an appropriate range Select the highest range and work down if the resistance level is unknown 2 Connect the Test Leads Red to V G Black to COM 3 Turn off power to the circu...

Page 6: ...Specifically a test lead is in a current connector and the Range Switch is set to measure some other function If in this configuration the DMM is connected to a voltage source very high and potential...

Page 7: ...Battery 9 V NEDA mA Fuse Fast Blow 250mA 600V Meterman FP375 To replace the 10 A fuse remove the battery remove the four rear case screws separate the case remove the 10 A fuse cover and remove and re...

Page 8: ...ts of material or workmanship within a period of one 1 year following the date of purchase of the multimeter by the original purchaser or original user Any multimeter claimed to be defective during th...

Page 9: ...o UL1244 EN61010 1 Cat II 600V Cat III 300V Class 2 Pollution degree II The 30XR is recommended for use with local level power distribution appliances portable equipment etc where only smaller transie...

Page 10: ...otection A mA input F 0 25A 600V Min I R 30 kA 6 3x32mm 10A input F 10A 600V Min I R 100 kA 10x38mm 10 A for 4 minutes maximum followed by a 12 minute cooling period RESISTANCE Ranges 200 2k 20k 200k...

Page 11: ...20k 200k 2k 200 200m 20m 20 20 2 2 V A 10A 200 2m BATT OFF 2m 200m 200 20m A 10A 1 5V 9V 3 4 2 1 V MAX 600V 600V 200mA MAX FUSED 10A MAX FUSED CAT 600V CAT 300V HOLD 30XR MIN MAX NON CONTACT VOLTAGE V...

Page 12: ...200m 20m 20 20 2 2 V A 10A 200 2m BATT OFF 2m 200m 200 20m A 10A 1 5V 9V MAX 600V 600V 30XR 2 3 MAX 600V 600V 200mA MAX FUSED 10A MAX FUSED CAT 600V CAT 300V HOLD 30XR MIN MAX NON CONTACT VOLTAGE V B...

Page 13: ...0k 200k 2k 200 200m 20m 20 20 2 2 V A 10A 200 2m BATT OFF 2m 200m 200 20m A 10A 1 5V 9V 2 3 5 4 1 6 MAX 600V 600V 200mA MAX FUSED 10A MAX FUSED CAT 600V CAT 300V HOLD 30XR MIN MAX NON CONTACT VOLTAGE...

Page 14: ...V 200mA MAX FUSED 10A MAX FUSED CAT 600V CAT 300V HOLD 30XR MIN MAX V BATT 9V BATT 1 5V COM 10A mA V 600 600 200 200 200m 200m 20M 2M 20k 200k 2k 200 200m 20m 20 20 2 2 V A 10A 200 2m BATT OFF 2m 200m...

Page 15: ...MAX FUSED CAT 600V CAT 300V HOLD 30XR MIN MAX NON CONTACT VOLTAGE V BATT 9V BATT 1 5V COM 10A mA V 600 600 200 200 200m 200m 20M 2M 20k 200k 2k 200 200m 20m 20 20 2 2 V A 10A 200 2m BATT OFF 2m 200m 2...

Page 16: ...30XR 30XR Professional Digital Multimeter with Non Contact Voltage Tester Users Manual Mode d emploi Bedienungshandbuch Manuale d Uso Manual de uso...

Reviews: