Meteor Lumenator 1018 Instruction Manual Download Page 1

1018 -

 IP65 INSTRUCTION MANUAL

 

INTRODUCTION:

 

The entire staff of Meteor would like to thank you for selecting the 

 

1018

 (IP-65) 

LUMENATOR

 as your fixture of choice. We have 

expended that extra effort to make sure you are more then pleased 
and satisfied with your purchase. 
 
Please check and make notice of any external cosmetic box damage 
caused by transportation. Notify your dealer 

– he in turn will notify us. 

If there is any damage 

– either inside the box or outside the box – 

DO NOT INSTALL THE DEVICE. There is a possibility that 
something may have come undone or unplugged. 
 
Unpack the Lumenator. Inside the box 

– you should find: 

 

 

- Protective packing 

 

 

- The Lumenator 

 

 

- One power cable 

 

 

- One XLR cable 

 

 

- Instruction manual 

 

DESCRIPTION:

 

 

FEATURES: 

 

 

-    

16

 

BIT DIMMING 

-

 

OVER TEMPERATURE Protection 

-

 

Can set DMX Address via Controller 

-

 

4, 6 or 9 DMX channels selectable for numerous 
applications. 

-

 

Automatic Identify Master Signal and change to 
Slave mode. 

-

 

Step-less RGBW COLOR mixing 

-

 

Color CALIBRATE function 

-

 

Equipped with 18 - 10w LEDS (4 in 1) 

-

 

Switch-mode power supply 

– 90v-240v AC. 

 

SAFETY INSTRUCTIONS:

 

This lighting fixture has left our factory in perfect condition. In order to 
maintain this condition and to ensure safe operation, it is absolutely 
necessary for the user to follow the instructions and caution notes written in 
this user manual. 
This fixture falls under protection-class 1. Therefore it is essential that the 
device should be grounded. 
 

 111111

   

 

MAKE SURE TO PRESS 

11t11THE

 MIDI/ADD BUTTON AFTER 

 

 
A qualified person must carry out the Electrical connection (to power). If the 
external “flexible” cable or power cord of this fixture is damaged, it HAS to 
be and will be replaced by the manufacturer or service agent or a similarly 
qualified person in order to avoid hazard or electrical shock. 
 
Make sure that the available voltage is NOT higher than stated at the end of 
this instruction guide / manual. 
 
Make sure the power cord is NEVER “crimped” or damaged by sharp edges. 
If it is 

– replacing a cable must be done by an authorized dealer trained in 

electrical repair. 
 
Always disconnect from electrical MAINS, when the 

1018

 

Lumenator

 is NOT 

in use or before cleaning it. Definitely before cleaning it. 
You could wind up getting a severe electrical shock. 
 
Only handle power cord by the PLUG.  
Never PULL out the plug by tugging on the power cord. 
Very strong possibility of getting serious electrical shock.    
 
NEVER LOOK DIRECTLY INTO THE LIGHT FIXTURE WHILE IT IS 
POWERED UP 

– SENSITIVE PEOPLE MAY SUFFER FROM EPILECTIC 

SHOCK (far fetched) BUT IT COULD HAPPEN. 
 

IMPORTANT

Damage caused by the disregard of this user manual IS NOT SUBJECT TO 
WARRANTY. The 

DEALER

 is not and will not ACCEPT LIABILITY for any 

resulting defects or problems caused by not following instructions. 
IGNORANCE is NOT A VALID WARRANTY ISSUE. 
 
 

*** PLEASE MAKE NOTE

:  

The power cord has been deliberately left OFF as most IP65 FIXTURES 
ARE USED OUTSIDE and are usually hardwired into APPROVED 
OUTSIDE WEATHER-PROOF JUNCTION BOXES. 
 

Do not plug into standard unprotected outlet, except for test purposes.

 

 

     
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 

                                                       

 2

 

                                                          

 

Summary of Contents for Lumenator 1018

Page 1: ...unded 111111 MAKE SURE TO PRESS 11t11THE MIDI ADD BUTTON AFTER A qualified person must carry out the Electrical connection to power If the external flexible cable or power cord of this fixture is damaged it HAS to be and will be replaced by the manufacturer or service agent or a similarly qualified person in order to avoid hazard or electrical shock Make sure that the available voltage is NOT high...

Page 2: ...e Chan ChanCH 6 6 Channel Mode Chan CH 9 9 Channel Mode 3 Continued Chan CH 7 7 Channel Mode diCS Inst Instant Mode Light on off instant DELA Delay Mode Light on light off delay for 5 Seconds CnFg parameter config Loc Active self lock keyboard no operation LoCc on the button for 30 seconds Unloc Deactivate self lock keyboard if NO operation on the button for 30 seconds StAt HoLd Hold DMX status wh...

Page 3: ...and down button AT the same time for 3 seconds Then the time will clear to 0000 simultaneously CCAL Color Calibrate Press ENTER button when menu reads CCAL Then choose the r g b calibrate by pressing UP or DOWN button Press ENTER to enter individual colors Adjust brightness of the color you choose pressing UP or DOWN button Press ENTER to confirm or ESC to return to main menu tEp Temperature Infor...

Page 4: ...this fixture Please use a soft lint free and moistened cloth NEVER USE ALCOHOL or any KIND OF SOLVENTS CAUTION ALWAYS DISCONNECT POWER FROM THE FIXTURE BEFORE ANY TYPE OF CLEANING OR MAINTENANCE IS PERFORMED There are no serviceable parts inside this unit Maintenance and service operations should be carried out by only authorized dealers or qualified service technicians If you need any spare parts...

Page 5: ......

Reviews: