Step-by-step Instructions:
Step 7: Remove lens (D) starting at one end.
Pull one side first, rotate and detach. Keep lens.
Step 8: Remove reflector mounting screws and
reflector/LED assembly. Note fixtures with optional
emergency pack have a test switch and indicator light
mounted on the reflector.
.
Step 9: Bring electrical supply to the fixture as needed.
Make sure all Retaining Clips are secured and
fastened.
Step 10: Perform electrical wiring inside the fixture and
re-attach reflector/LED assembly with mounting screws.
Optional emergency driver must be fed from the same
branch circuit as the AC driver
Step 11: Re-attach lens. Start with one side first and
close the other side starting from the corner.
Step 12: Re-attach the filler and magnet E).