background image

Page 

1

 of 

4

 

 

Specifications and design subject to change without notice. 

 

570 Southgate Drive, Guelph, Ontario, Canada, N1G 4P6 

www.metalumen.com

  

 

Phone: 800-621-6785 Fax: 519-822-4589 

 
 
 

IS-0244-03 

rev.00

 

GRANDE RECESSED TBAR LED 

INSTALLATION INSTRUCTIONS 

 
 
 

NOTE:

  

The following instructions provide general guidelines for product installation. For additional information consult the 

applicable electrical codes or contact factory directly for support before attempting anything with uncertainty. 

 

CAUTION:

 

Do not assemble fixture runs on floor

.

 

 

WARNING: 

Risk of fire and electrical shock. 

DISCONNECT POWER AT ELECTRICAL PANEL 

before installing or 

servicing this product. 

 

General Safety Instructions: 

1.  Read all instructions prior to installing this fixture.  
2.  This product must be installed in accordance with the applicable installation code by a person familiar with the 

construction and operation of the product and the hazards involved. 

3.  All wiring must be performed by a qualified electrician in accordance with national and local building and electrical codes. 
4.  This fixture must be suitably grounded for your protection against shock hazards and to assure proper operation. 
5.  Make sure that the power source conforms to the requirements of this fixture. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Wiring Diagram:  

 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 

MAIN PARTS LIST: 

A.  Luminaire enclosure 
B.  Tbar Hanger Bracket 
C.  End plate 
D.  Lens 
E.  Lens Filler &Magnet 
F.  Retainer Clip 

 
OTHER PARTS: 

 

Reflector/LED assembly 
 

Standard wiring 

 

With optional Emergency Pack 

 

Summary of Contents for Grande RM4D Series

Page 1: ...ervicing this product General Safety Instructions 1 Read all instructions prior to installing this fixture 2 This product must be installed in accordance with the applicable installation code by a person familiar with the construction and operation of the product and the hazards involved 3 All wiring must be performed by a qualified electrician in accordance with national and local building and el...

Page 2: ... by step Instructions Step 1 Remove fixture packaging note marked supply wires coming out at one end of the luminaire Step 2 Ensure Retainer clip F is loose If not loosen retainer clips 4 Step 3 Place Luminaire Fixture A into ceiling and rest on tbar Step 4 Adjust Retainer Clips so its sits tight against tbar Step 5 Once Retainer clips are tight against tbar fasten screws to secure Retainer Clips ...

Page 3: ...ng screws and reflector LED assembly Note fixtures with optional emergency pack have a test switch and indicator light mounted on the reflector Step 9 Bring electrical supply to the fixture as needed Make sure all Retaining Clips are secured and fastened Step 10 Perform electrical wiring inside the fixture and re attach reflector LED assembly with mounting screws Optional emergency driver must be ...

Page 4: ...t to change without notice 570 Southgate Drive Guelph Ontario Canada N1G 4P6 www metalumen com Phone 800 621 6785 Fax 519 822 4589 IS 0244 03 rev 00 GRANDE RECESSED TBAR LED INSTALLATION INSTRUCTIONS Step by step Instructions Installed Fixture A ...