Pict. 3

Connection and installation measures:
TYPE   

        EZV 10 

 

 

EZV 5

Model       EZV 10N 

     EZV 10P 

EZV 5N  

EZV 5P

 A(mm)      480      

     480   

406 

 

406

 B(mm)      363   

        -   

297 

 

   -

 C(mm)      326   

     326   

274 

 

274

 D(mm)      230   

     230   

214 

 

214

 E(mm)          -   

     166   

   - 

 

161

 F(mm)       190   

     190   

140 

 

140

CONNECTION TO WATER SUPPLY

 

Input for cold water on the water heater  is marked with blue 

ring  while  hot  water  output  is  marked  with  a  red  ring,  which  is  to 

be  respected  when  connecting  water  heater  to  water  supply.   The 

models marked N are for installation above the fitting (pipe), while 

P models are for installation below fitting (pipe)  - see Picture 2 Low 

capacity water heater works without pressure (open system) and it is 

possible to use water only at one spot in the house.

 

The fittigns/mixing pipes appropriate for work without pres-

sure have to be used with this water heater – water inlet into the fit-

ting not over 3-4 mm diameter, and for low installation models, the 

fitting should have 3 pipes. On the inlet pipe before the mixing unit 

a non-return valve should be mounted to prevent tank to empty in 

case of pressure fall in water supply pipeline. 

Summary of Contents for EZV 10N

Page 1: ...INSTRUCTIONSFORINSTALLATION USEAND CARE OFWATERHEATERS EZV5and10litres...

Page 2: ...2 CONTENTS TECHNICAL INFORMATION 3 INSTALLATION 3 CONNECTION TO WATER SUPPLY 5 STEPS FOR CONNECTION TO WATER SUPPLY 6 CONNECTION TO POWER SUPPLY 7 USE AND MAINTENACE 7 WASTEDISPOSAL 8...

Page 3: ...ted Product technical characteris tics are given on the sticker Table with Characteristics between con nection pipes Picture 1 shows the water heater with all components P low installatiuon N wall hig...

Page 4: ...haracteristics of low capacity water heater Type EZV 10 EZV 5 Model EZV 10N EZV 10P EZV 5N EZV 5P Capacity litres 10 5 Nominal pressure Mpa 0 0 Weight when full of water kg 14 2 8 1 Heater power W 200...

Page 5: ...odels marked N are for installation above the fitting pipe while P models are for installation below fitting pipe see Picture 2 Low capacity water heater works without pressure open system and it is p...

Page 6: ...the water heater at desired place near the fitting For P ver sion the installation is made below the fitting and for N version above the fitting see picture 2 2 Connect the water heater and fitting us...

Page 7: ...er heater it must be unplugged from the power supply USE AND CARE Switch on the heating of water by turning the button of the regulator to a certain position depending on desired temperature Maximum w...

Page 8: ...pipe First filling and heating should be monitored till the moment the signal lamp goes off WASTE DISPOSAL WHAT AFTER YOUR WATER HEATER IS NO MORE USABLE The accumulation water heaters and the packing...

Reviews: