background image

10

ENGLISCH

ENG

Do not keep the hot-air blower trained on a single 
spot for more than a short period of time.

Be aware that heat can be transferred to 
flammable materials outside the operator's line of 
vision.

Use the hot-air blower in well-ventilated spaces 
only.

Do not inhale any vapours released during 
operation.

Do not leave the hot-air blower unattended when 
in use.

After use, place the hot-air blower on its bearing 
surfaces and allow to cool down before returning it 
to its storage location.

Warning: to prevent any risk of burns avoid 
touching the blower nozzle.

Children should be supervised to ensure that they 
do not play with the tool.

Refer to illustrations on page 3.

1 (HE 2300 Control) LCD temperature display
2 Non-slip bearing surfaces on housing
3 Air filter
4 (HE 2000, HE 2300 Control)

Switch (two-part)
Air temperature and air volume can be set 
independently of each other.
(H 1600)
Slide-switch for setting air temperature 
and air volume

Before initial use, check that the mains 
voltage and mains frequency stated on 
the rating plate match the figures for 
your own mains supply.

Avoid overheating:
- Do not work with the air filters 
obstructed. 

Clean the air filters in good 

time.

- Do not obstruct the blow-out pipe. 

Maintain a minimum distance of 4 cm to the 
workpiece and do not direct the air jet 
vertically onto the workpiece.

Stationary use

To use the hot-air blower in a stationary position, 
set it up on its non-slip bearing surfaces (2).

H 1600

Use the slide-switch (4) to switch the tool on and 
off and to select one of the three blower and 
temperature settings.

HE 2000, HE 2300 Control

Use the two-part switch (4) to set the temperature 
and air volume settings independently of each 
other.
Use the black slide-switch to switch the tool on 
and off and to select one of the three blower 
settings.

Use the red slide to continuously adjust the air 
temperature to any setting within its range.
The electronic system serves to monitor 
temperature and thus protects the heating coil.

HE 2300 Control

The pre-selected air temperature can be read in 
the LCD temperature display (1).
After the temperature has been pre-selected, the 
display shows the temperature of the emerging air 
after 3 seconds (displayed in 10°C increments).

------------------------------------------------------

Blower stage I:

The cold blower stage 
- accelerates the cooling down of a previously 
warmed workpiece and 
- accelerates the cooling down of the device itself 
after working.

Blower stage II:

The first warm blower stage (operating with a 
reduced fan speed) is used to carefully warm 
up a workpiece. 
Heating the air causes it to expand, i.e. it increases 
in volume, thus increasing air throughput.

Blower stage III:

The second warm blower stage provides 
maximum air throughput.

------------------------------------------------------

5

Overview

6

Operation

Reviews: