25
English
USING THE HOOK
WARNING
●
When using the hook, turn o
ff
the power
switch (green light “OFF”). Pay su
ffi
cient
attention so that the main equipment does
not fall.
If the tool falls, there is a risk of accident.
Hook can be installed on the left or right side.
(1) Securely hold the main unit and remove the screw
using an allen wrench.
(2) Remove the hook and hook plate.
(3) Install the hook on the other side and securely
fasten with screw.
CLEARING A JAM
If nails are jammed in
fi
ring head, remove it, and adjust the
nailing in the following order.
CAUTION
●
Remove the battery from the Nailer.
Remove the battery from the Nailer. (See page 16)
Remove all nails. (See page 23)
Remove the M5 bolts with wrench.
Do not loosen
these screws
Pull magazine away from the
fi
ring head, and clear
jam.
CAUTION
●
NEVER hit the driver blade.
●
NEVER point the tool at yourself or another
person, to avoid risk of injury by mis-
fi
ring.
Even if the battery is removed from the nailer,
there is still energy of compressed air remaining
inside.
Attach the magazine to the injector and tighten with
the M5 bolt.
NOTE
●
In case of frequent jam, contact a metabo HPT
authorized service center.
000Book̲NR3665DA̲metabo.indb 25
000Book̲NR3665DA̲metabo.indb 25
2021/02/22 12:20:26
2021/02/22 12:20:26