12
English
OVERLOAD PROTECTOR
This air compressor is equipped with a thermal overload
device which will turn the air compressor o
ff
automatically,
if the air compressor becomes overheated. If the motor
turns OFF repeatedly, check for the following possible
causes
fi
rst: Low Voltage from the outlet. Lack of proper
ventilation or outside air or room temperature too high.
Extension cord too long or wrong gauge wire used.
To reset the air compressor:
(1) Turn the air compressor o
ff
.
(2) Unplug the air compressor and allow it to cool for 30
minutes.
(3) Plug the air compressor into an approved outlet.
(4) Turn the air compressor on.
DUTY CYCLE:
To avoid overheating of the electric motor, this compressor
is designed for intermittent operation as indicated on the
dataplate:
S3 50 means 5 minutes ON and 5 minutes OFF.
If the compressor run time exceeds the S3 50 duty cycle,
then the application requires more air than the compressor
is capable to deliver.
To ensure tool performance, the SCFM output of the
compressor should exceed the CFM requirement of the
tool by 20%.
ASSEMBLY
UNPACKING
This product has been shipped completely assembled.
○
Carefully remove the compressor and any
accessories from the box. Make sure that all items
listed in the packing list are included.
○
Inspect the compressor carefully to make sure no
breakage or damage occurred during shipping.
○
Do not discard the packing material until you have
carefully inspected and satisfactorily operated the
compressor.
PACKING LIST
– Air
Compressor
– Instructions
Manual
WARNING:
If any parts are missing do
not operate the compressor
until the missing parts are
replaced. Failure to do so
could result in possible
serious personal injury.
WARNING:
Do not attempt to modify
this compressor or
create accessories not
recommended for use with
this compressor. Any such
alteration or modi
fi
cation is
misuse and could result in a
hazardous condition leading
to possible serious personal
injury.
ATTACHING HOSE
○
Insert the hose into the quick coupler already installed
on the compressor (Fig. 3).
WARNING:
Do not attach any tools to the
open end of the hose until
start-up has been completed.
○
Firmly grasp the open end of the hose; hold facing
away from yourself and others.
On/O
ff
switch
Safety
valve
Quick
couplers
Regulator
pressure gauge
Pressure
regulator knob
Tank pressure
gauge
Fig. 3
00Book̲EC914S̲NA.indb 12
00Book̲EC914S̲NA.indb 12
2020/06/08 13:46:34