PANIC (LEGOS 3)
It is possible to trigger a 10 second alarm cycle by pressing the second button on the remote control. This alarm cycle can be interrupted
by pressing the same button again.
SPECIAL FUNCTIONS – CONFIGURATION
It is possible to set some alarm functions to adapt the alarm system to the motorcycle and its driver’s needs. To set the functions,
which are described in the table below, proceed as follows:
1. arm the alarm system with the remote control
2. turn the ignition key ON within 10 seconds: the siren will make a BEEP sound to confirm selection
3. press the remote control’s button briefly 4 times: the siren will make 4 BOOP sounds to confirm reception of the signal
4. turn the motorcycle’s ignition key OFF
5. turn the motorcycle’s ignition key ON and then OFF the same number of times as the number of the special function to be set (see
table). Leave the ignition key ON the last time: the LED is on
6. briefly press the button of the remote control once if the settings described in the first column are required (see table - BEEP column)
7. briefly press the button of the remote control twice if the settings described in the second column are required (see table - BOOP
column)
8. turn the ignition key OFF and briefly press the button of the remote control to exit programming mode, otherwise repeat from step 5
to set another function.
FUNCTION
BEEP
YES
NO
NO
NO
NO
YES
YES
YES
BOOP
1
2
3
4
5
6
7
8
Buzzer when arming and disarming
Direction indicators when arming and disarming
Horn/siren alarm output or control of activation
Control of alternate horn or continuous siren
Passive arming only of immoboliser or also alarm function
Passive arming with movement sensor enabled
Alarms of cyclical or single contacts
Allarm
Activation
Continuous
Derived
Also alarm
Alternated
Immobiliser
Cyclical
Enabling of automatic arming
14
TABLE SPECIAL FUNCTIONS – CONFIGURATION
(factory settings in bold type )
EN