background image

+15

10 AMP

NO

IMMOBILISER (FAIL SAFE SYSTEM)

Positive Logic (the relay switches over when the central unit is disarmed and ignition  +15 is present.)

SWITCH PROTECTION

HORN WITH POSITIVE CONTROL – SUBKEY

HORN WITH NEGATIVE CONTROL – SUBKEY

Fig.5  If not used, connect the wire to an earth point

+12V

+12V

Fig.6

+12V

+12V

Fig.7

Fig.4

yellow/green

SWITCH

TO BE

INSTALLED

SWITCH

TO BE

INSTALLED

HORN

HORN

P600 DIODES
to be installed

ORIGINAL
CONTROL

ORIGINAL
CONTROL

SUPPLEMENTARY

RELAY

SUPPLEMENTARY

RELAY

DIRECTION

INDICATORS

TO THE ORIGINAL

CONTROLS

IGNITION 

KEY SWITCH

IGNITION 

KEY SWITCH

FINAL CHECK

When installation is complete and the harness connector has been connected to the alarm central unit, proceed as follows:

1.

re-connect the battery of the machine.

2.

Turn the machine’s ignition key ON and then OFF again

3.

50 seconds later, the immobiliser will automatically arm: the direction indicators flash briefly once, the siren beeps once and the LED starts

to flash very slowly.

4.

Disarm the alarm system using the remote control: the direction indicators flash once, the siren beeps once and the LED switches off.

5.

Within 50 seconds turn the machine on to check that the connections made are operating correctly.

6.

Switch the engine off and turn the machine’s ignition key OFF. Arm the alarm system within 50 seconds:  the direction indicators flash twice,

the siren beeps twice and the LED flashes, with very brief switches off.

7.

During the initial 26 seconds immunity period, do the following tests which should provide a BEEP if they have a positive result:

a. Turn the machine’s key ON.
b. Activate any switch protection (opening of the saddle compartment, removal of the firewall, …)
c. Move the machine to activate its tilt protection.
The timing of the immunity period is reset every time a beep is heard.

8.

Once the immunity period is over, the LED flashes with an reversed sequence (long switches off) and the alarm system will be triggered for

one 26 sec. cycle by the activation of any of the protection switches, or by turning the machine’s key ON, by moving the machine0: the siren will
produce its distinctive, modulated sound, the direction indicators flash and the horn (if connected) will sound intermittently. Check the engine
immobiliser operates correctly during the alarm cycle.

9.

When the alarm system is disarmed, the LED will remain on and the siren will emit a BOOP sound to signal that it has memorised an alarm

trigger: refer to the user manual for the code of this signal and for all other features/settings of the product..

brown

brown

light blue

purple

Fig.2

dar

k blue

grey

RELAY

DEF-COM central unit

Ignition pack,
coil, petrol pump

NC

C

MotorCycle Alarm

by

DEF•COM 3

INSTALLATION MANUAL

INSTALLATION

EN

CONNECTIONS

Positive

supply

 (+12V)

Mount

15A

fuse

Direction

 indicators

Ignition switch

positive supply

(+15)

Negative

command

of horn relay

Protection against

removal of earth connection

(connect to

earth if not used)

ANTENNA

(do not cut and do not tape

together with rest of cable

harness)

Protection for
earth contact

NO

LED

Immobiliser

NC

RED

BLACK

BLACK

RED

WHITE

PURPLE

LIGHT BLUE

LIGHT BLUE

ORANGE

BROWN

DARK BLUE (C)

GREY (NO)

Negative 

supply 

( - )

YELLOW/GREEN

Fig.1

GENERAL WIRING DIAGRAM

+

80°C

H

2

O

<±45°

>±45°

KO

KO

OK

OK

BLOCCHETTO

CHIAVE

AVVIAMENTO

RELE'

SUPPLEMENTARE

Fig.3

blu

+ 15

30

85

87

87/A

86

grey

NC

C

From the magneto

COIL

RELAY DEF-COM central unit

NO

NO

NC

C

SUPPLEMENTARY

RELAY

IGNITION

KEY SWITCH

Summary of Contents for Def Com 3

Page 1: ...con il radiocomando le frecce effettueranno 2 lampeggi la sirena emetterà 2 BEEP ed il LED lampeggia con brevi spegnimenti 7 durante l immunità iniziale di 26 sec eseguire i seguenti test che devono generare un BEEP se l esito è positivo ruotare la chiave del motociclo in posizione ON attivare gli eventuali pulsanti di protezione apertura vano sella rimozione paratie muovere il motociclo attivando...

Page 2: ...h protection opening of the saddle compartment removal of the firewall c Move the machine to activate its tilt protection The timing of the immunity period is reset every time a beep is heard 8 Once the immunity period is over the LED flashes with an reversed sequence long switches off and the alarm system will be triggered for one 26 sec cycle by the activation of any of the protection switches o...

Page 3: ... brèves 7 Pendant l immunité initiale de 26 secondes effectuez les tests qui doivent produire un BEEP si le résultat est positif tournez la clé du motocycle sur la position ON activez les boutons éventuels de protection ouverture selle dépose de pièces bougez le motocycle pour activer la protection antidéplacement A chaque BIP le temps d immunité initiale redémarre de zéro 8 Après avoir terminé l ...

Page 4: ... con breves apagados 7 Durante la inmunidad inicial de 26 seg realizar el siguiente test que deben generar un BEEP si el resultado es positivo girar la llave de contacto de la moto hacia ON activar los pulsadores de protección apertura del cofre del asiento manipulación del carenado mover la moto activando la protección antidesplazamiento A cada BEEP el tiempo de inmunidad comienza desde cero 8 Un...

Page 5: ...idade inicial de 26 seg efectuar os seguintes testes que devem gerar um bip no caso em que êxito seja positivo rodar a chave do motociclo na posição ON activar os eventuais botões de protecção abertura do compartimento da sela desmontagem das divisórias etc deslocar o motociclo activando a protecção contra as deslocações A cada bip o tempo de imunidade volta a partir de zero 8 Terminada a imunidad...

Page 6: ...ge blinkt mit kurzen Dunkelzeiten 7 Während der anfänglichen Immunitätszeit von 26 Sekunden die folgenden Tests ausführen die ein BEEP erzeugen müssen um positiv zu sein Den Zündschlüssel des Krads auf ON drehen Die etwaigen Kontaktschalter aktivieren Öffnung des Sattelraums Entfernen von Trennblechen Das Krad bewegen um den Schutz gegen Bewegen zum Ansprechen zu bringen Bei jedem BEEP läuft die a...

Page 7: ...kort uit 7 tijdens de instelperiode van 26 seconden de volgende tests uitvoeren deze moeten een BEEP geluid veroorzaken als de uitslag positief is draai de sleutel van de motorfiets in de stand ON activeer de eventuele beveiligingsknoppen opening zadelruimte verwijdering scheidingsplaten verplaats de motorfiets waardoor de verplaatsingsbeveiliging geactiveerd wordt Bij ieder BEEP geluid begint de ...

Page 8: ...ÏÔ ı ÔÎÈÌ Ë ıÂÙÈÎ Î ÛË ÙˆÓ Ô Ô ˆÓ Ú ÂÈ Ó Â È Â ÈÒÓÂÙ È ÌÂ Ó Ì È Á Ú ÛÙ ÙÔ ÎÏÂÈ ÙÔ ÈÎ ÎÏÔ ÛÙË ı ÛË ON È ÛÙ ٠fiÓ Ï ÎÙÚ ÚÔÛÙ Û ÓÔÈÁÌ Û Ï Ê ÚÂÛË ÙÌËÌ ÙˆÓ ÌÂÙ ÎÈÓ ÛÙ ÙÔ Î ÎÏÔ ÂÓÂÚÁÔ ÔÈÒÓÙ ÙËÓ ÚÔÛÙ Û ÌÂÙ Î ÓËÛË Â Î ıÂ Ì È Ô ÚfiÓÔ ÙÔ ÂÚÁÔÛÙ ÛÈ ÎÔ ÂÚÈıˆÚ Ô ÍÂÎÈÓ ÂÈ fi ÙÔ ÌË Ó 8 ªÂÙ ÙËÓ ÚÔ Ô ÙÔ ÂÚÁÔÛÙ ÛÈ ÎÔ ÂÚÈıˆÚ Ô ÙÔ LED Ó ÔÛ ÓÂÈ Ì ÓÂÛÙÚ ÌÌ ÓË Ê ÛË Ú ÙÂÙ Ì Ó Û ËÛ Ì Ù Î È Ë ÂÓÂÚÁÔ Ô ËÛË Â ÊÒÓ ÚÔÛÙ Û ÙÔ...