+15
✄
10 AMP
NO
IMMOBILISER (FAIL SAFE SYSTEM)
Positive Logic (the relay switches over when the central unit is disarmed and ignition +15 is present.)
SWITCH PROTECTION
HORN WITH POSITIVE CONTROL – SUBKEY
HORN WITH NEGATIVE CONTROL – SUBKEY
Fig.5 If not used, connect the wire to an earth point
+12V
+12V
Fig.6
+12V
+12V
Fig.7
Fig.4
yellow/green
SWITCH
TO BE
INSTALLED
SWITCH
TO BE
INSTALLED
HORN
HORN
P600 DIODES
to be installed
ORIGINAL
CONTROL
ORIGINAL
CONTROL
SUPPLEMENTARY
RELAY
SUPPLEMENTARY
RELAY
DIRECTION
INDICATORS
TO THE ORIGINAL
CONTROLS
IGNITION
KEY SWITCH
IGNITION
KEY SWITCH
FINAL CHECK
When installation is complete and the harness connector has been connected to the alarm central unit, proceed as follows:
1.
re-connect the battery of the machine.
2.
Turn the machine’s ignition key ON and then OFF again
3.
50 seconds later, the immobiliser will automatically arm: the direction indicators flash briefly once, the siren beeps once and the LED starts
to flash very slowly.
4.
Disarm the alarm system using the remote control: the direction indicators flash once, the siren beeps once and the LED switches off.
5.
Within 50 seconds turn the machine on to check that the connections made are operating correctly.
6.
Switch the engine off and turn the machine’s ignition key OFF. Arm the alarm system within 50 seconds: the direction indicators flash twice,
the siren beeps twice and the LED flashes, with very brief switches off.
7.
During the initial 26 seconds immunity period, do the following tests which should provide a BEEP if they have a positive result:
a. Turn the machine’s key ON.
b. Activate any switch protection (opening of the saddle compartment, removal of the firewall, …)
c. Move the machine to activate its tilt protection.
The timing of the immunity period is reset every time a beep is heard.
8.
Once the immunity period is over, the LED flashes with an reversed sequence (long switches off) and the alarm system will be triggered for
one 26 sec. cycle by the activation of any of the protection switches, or by turning the machine’s key ON, by moving the machine0: the siren will
produce its distinctive, modulated sound, the direction indicators flash and the horn (if connected) will sound intermittently. Check the engine
immobiliser operates correctly during the alarm cycle.
9.
When the alarm system is disarmed, the LED will remain on and the siren will emit a BOOP sound to signal that it has memorised an alarm
trigger: refer to the user manual for the code of this signal and for all other features/settings of the product..
brown
brown
light blue
purple
Fig.2
dar
k blue
grey
RELAY
DEF-COM central unit
Ignition pack,
coil, petrol pump
NC
C
MotorCycle Alarm
by
DEF•COM 3
INSTALLATION MANUAL
INSTALLATION
EN
CONNECTIONS
Positive
supply
(+12V)
Mount
15A
fuse
Direction
indicators
Ignition switch
positive supply
(+15)
Negative
command
of horn relay
Protection against
removal of earth connection
(connect to
earth if not used)
ANTENNA
(do not cut and do not tape
together with rest of cable
harness)
Protection for
earth contact
NO
LED
Immobiliser
NC
RED
BLACK
BLACK
RED
WHITE
PURPLE
LIGHT BLUE
LIGHT BLUE
ORANGE
BROWN
DARK BLUE (C)
GREY (NO)
Negative
supply
( - )
YELLOW/GREEN
Fig.1
GENERAL WIRING DIAGRAM
+
80°C
H
2
O
↕
<±45°
>±45°
↕
KO
KO
OK
OK
BLOCCHETTO
CHIAVE
AVVIAMENTO
RELE'
SUPPLEMENTARE
Fig.3
blu
+ 15
30
85
87
87/A
86
grey
NC
C
From the magneto
COIL
RELAY DEF-COM central unit
NO
NO
NC
C
SUPPLEMENTARY
RELAY
IGNITION
KEY SWITCH