Product description 

Spraying / atomizing device for medium size areas and 

volume. the machine consumes little electrical power 

during its work. In addition, due to its high efficiency, it 

allows the spraying of one hundred square meters in just 

ten minutes. The droplet size and spray distance can be 

adjusted. Its field of application is very large, obtaining 

good results in almost all environments and 

circumstances. Its handling is safe. 
 

Basic principles of operation 

A high-powered motor moves the fan blades to generate 

a high-speed, high-flow airflow. At the same time, the 

motor increases the pressure in the tank which has  the 

disinfectant solution and pushes it towards a nozzle 

designed to inject the liquid  into the center of the air 

stream. The combined effect of air and liquid injector 

produces a Venturi effect that atomizes the disinfectant 

into fine droplets that are dispersed by the air jet over a 

long distance. 
 

Important information 

1.

 

Before starting up the machine, check that the supply 

voltage is 230  V,  50  Hz.  Also make sure that the 

intake air filter is in its housing and it is not clogged. 

If the air filter is wet, wait until it dries before turning 

on the machine. 

2.

 

Do not overfill the tank with sanitizing solution. Stay 

below the Max level line. The tank capacity is 5 L. 

Avoid overflows. 

3.

 

To ensure that the spraying effect is optimal, the 

motor speed must be constant. In case the spray 

distance is too close, adjust the jet launch distance 

control valve. 

4.

 

Only water-soluble liquids can be used. To keep the 

air filter clean, make sure that the liquid to be 

nebulized is free of impurities. 

5.

 

Turn off the appliance when any of the following 

circumstances occur: the machine is exposed to rain 

or  gets wet; the engine stopped working; abnormal 

noises in the engine; disinfectant solution leak; the 

engine fails to start; and / or other potentially 

dangerous situations. 

6.

 

During the use of the device, you must wear a 

disposable protective suit and a mask for the eyes 

and respiratory system

. Consult the sanitizer 

solution  manufacturer's  recommendations for safety 

measures. 

7.

 

After using the appliance, wipe off with water any 

residual solution splashes. The tank must be cleaned 

of residual disinfectant solution strictly following the 

instructions of the manufacturer of the disinfectant 

product. Finally, turn on the machine and empty the 

residual clean water that remains in the tank. The 

machine must be completely dry and without 

disinfectant product. The place of storage of the 

appliance must avoid any exposure to humidity, the 

sun, shock and be out of the reach of children. 

8.

 

Never plug in or unplug the appliance with wet 

hands. The machine should not be stored near 

flammable, explosive products or high temperature 

places. Do not pull the power cord with force to 

unplug it from the mains. 
 

Instructions for use 

1.

 

Fill the tank with the already mixed sanitizing 

solution and then close the cap. 
Important: 
A. Do not immerse the level control valve inside the 

tank. 

B. Do not overfill the tank. The maximum volume is 

5 liters. Exceeding it can damage the motor. 

C. Carry out the filling operations with the machine 

unplugged. 

2.

 

 Plug the appliance into the mains. All machines are 

equipped with electrical leakage protector.  Before 

starting to operate the appliance, it is recommended 

to check the operation of this safety device. To do 

this, you must press the test button and verify that it 

disconnects from the mains automatically. If it 

works properly, press the reset button. You can then 

start using the machine 

3.

 

Actuate the machine's power switch to start it. 

4.

 

You can adjust the droplet size using the rotary knob 

on the spray gun. 

5.

 

Place the device on your shoulder on the strap and 

begin to spread the disinfectant cloud by directing 

the spray cannon towards the target spaces as you 

walk. Avoid directing it towards people, animals or 

sensitive areas. Also, do not mist areas where there 

is electrical activity (electrical panels, cables, etc.). 

6.

 

After using the appliance, clean the residual solution 

as specified in the section “

important aspects

”. 

Cleaning and maintenance work must always be 

carried out with the appliance switched off. 

 

Summary of Contents for 100520

Page 1: ...Rev 03 09 2020 Ref 100520 ES 3 Manual original EN 6 ...

Page 2: ... desechable y máscara protectora de los ojos y vías respiratorias Consulte las recomendaciones del fabricante de la solución desinfectante en lo relativo a las medidas de seguridad 7 Después del uso del aparato limpie las salpicaduras de solución residual con agua El tanque se debe limpiar de restos de solución desinfectante siguiendo estrictamente las instrucciones del fabricante del producto des...

Page 3: ...ísticas técnicas Alimentación AC230V 50 Hz Potencia 1000 W Capacidad del tanque 5 L Volumen del pulverizador 470 mL min ajustable Tamaño de gotícula 10 150 μm Alcance efectivo 6 8 m Peso neto 2 6 kg Peso bruto 3 7 kg Dimensiones 570 x 250 x 335 mm Declaración de conformidad UE La empresa Talleres Mestraitua S L con domicilio social Txori erri Etorbidea 60 48150 Sondika Bilbao España por la present...

Page 4: ...ive suit and a mask for the eyes and respiratory system Consult the sanitizer solution manufacturer s recommendations for safety measures 7 After using the appliance wipe off with water any residual solution splashes The tank must be cleaned of residual disinfectant solution strictly following the instructions of the manufacturer of the disinfectant product Finally turn on the machine and empty th...

Page 5: ...tage AC230V 50 Hz Power 1000 W Tank capacity 5 L Sprayer volume 470 mL min adjustable Droplet size 10 150 μm Effective range 6 8 m Net weight 2 6 kg Gross weight 3 7 kg Dimensions 570 x 250 x 335 mm Declaration of conformity UE The firm Talleres Mestraitua S L with social address Txori erri Etorbidea 60 48150 Sondika Bilbao Spain Hereby declares that the product Electrical nebulizer for disinfenct...

Page 6: ...Your trusted brand Talleres Mestraitua S L Txori erri Etorbidea 60 T 34 944530388 F 34 944711725 mestra mestra es www mestra es 48150 SONDIKA BILBAO ESPAÑA ...

Reviews: