12
FAQ
If the machine can't work properly, please kindly check
as below before you send it out for repair.
Problem
Checking
methods
Solution
Do not work Please check if the
plug is
disconnected from
the socket.
Power plug
should be
plugged properly
Please check if the
filter cover is
installed
completely
Recover the
filter cover
correctly
Odor cannot
be removed
Is there a very
strong odor in the
using
environment?
(Notes: air should
be purified
continuously)
Suggesting to
ventilate, then
start up the
machine.
Does the using life
time for activated
carbon filter come
to the end?
Please replace
new filters.
High noise
Is the PE bag for
filter removed?
Please take out
filters and tear
off PE bag.
Does the using life
time for HEPA
come to the end?
Please replace
new HEPA.
Air quality
indicator
doesn’t
work
properly
Is the air humidity
very high?
Is the machine
affected by fume
or sprays?
Please move the
machine to
another
room to test
again.
Small
changes for
humidity or
temperature
data
Is the machine
using area too big?
Please use this
machine in
applicable room.
If the problem still existed after above inspections, please
disconnect the power and send it for repair.
Maintenance and cleaning
instruction
Please remove plug from the socket before cleaning and
maintenance.
Cleaning the body for this device by damp cloth, then
wipe it dry.
If machine is too dirty, neutral detergent can be used
for cleaning, but please dilute the detergent before use.
Do not clean the unit with solvent.
TECHNICAL PARAMETERS
Filter parameters
Description
Size
Life time
HEPA
250
x
100x20
mm
About 12
months
Activated carbon
+ photo catalyst
238x
100x
1
0
mm
About 6
months
UV parameters
Description:
UV lamp
Model:
T5
Power rating:
6 W
Voltage:
220
∼
240 V
Wave length
:
254 nm
Life time:
8000 h
Parameters of the unit
Voltage supply:
220
-
240 V, 50 Hz
Air flow volume:
≥
280 m
3
/h
Noise level:
≤
44 dB(A)
Length of power cord:
≥
1.4 m
Product size:
360 x 206 x 536 mm
Net weight:
6.3 kg
Power rating:
45 W
Applicable area:
30
-35 m
2