background image

 

12 

FAQ

 

If the machine can't work properly, please kindly check 

as below before you send it out for repair. 

Problem 

Checking 

methods 

Solution 

Do not work  Please check if the 

plug is 

disconnected from 

the socket. 

Power plug 

should be 

plugged properly 

Please check if the 

filter cover is 

installed 

completely 

Recover the 

filter cover 

correctly 

Odor cannot 

be removed 

Is there a very 

strong odor in the 

using 

environment? 

(Notes: air should 

be purified 

continuously) 

Suggesting to 

ventilate, then 

start up the 

machine. 

Does the using life 

time for activated 

carbon filter come 

to the end? 

Please replace 

new filters. 

High noise 

Is the PE bag for 

filter removed? 

Please take out 

filters and tear 

off PE bag. 

Does the using life 

time for HEPA 

come to the end? 

Please replace 

new HEPA. 

Air quality 

indicator 

doesn’t 

work 

properly 

Is the air humidity 

very high? 

Is the machine 

affected by fume 

or sprays? 

Please move the 

machine to 

another 

room to test 

again. 

Small 

changes for 

humidity or 

temperature 

data 

Is the machine 

using area too big? 

Please use this 

machine in 

applicable room. 

If the problem still existed after above inspections, please 

disconnect the power and send it for repair. 

 
 
 
 
 
 
 
 
 

Maintenance and cleaning 

instruction 

Please remove plug from the socket before cleaning and 

maintenance. 

 

 

Cleaning the body for this device by damp cloth, then 

wipe it dry. 

 

If machine is too dirty, neutral detergent can be used 

for cleaning, but please dilute the detergent before use. 

 

Do not clean the unit with solvent. 

 

 
 

TECHNICAL PARAMETERS 

Filter parameters 

Description 

Size 

Life time 

HEPA 

250

x

100x20 

mm 

About 12 

months 

Activated carbon 

+ photo catalyst 

238x

100x

1

mm 

About 6 

months 

UV parameters 

Description: 

UV lamp 

Model: 

T5 

Power rating: 

6 W

 

Voltage: 

220

240 V

 

Wave length

254 nm 

Life time: 

8000 h

 

Parameters of the unit 

Voltage supply: 

220

-

240 V, 50 Hz

 

Air flow volume: 

 

280 m

3

/h 

Noise level: 

 44 dB(A) 

Length of power cord: 

 1.4 m 

Product size: 

360 x 206 x 536 mm

 

Net weight: 

6.3 kg 

Power rating: 

45 W

 

Applicable area: 

30

-35 m

2

 

 

Summary of Contents for 100512

Page 1: ...Rev 10 09 2020 Ref 100512 ES 3 Manual original EN 8...

Page 2: ...l de control Control panel Asa Handle Cubierta filtro Filter cover Entrada aire Air inlet Salida aire Air outlet Etiqueta Label Agujero cable alimentaci n Power cord hole Atenci n Retirar bolsa de los...

Page 3: ...eaken the insulation even cause fire Take out the plug and clean it with dry cloth Please remove the plug from the socket if not using for a long period ATENCI N Mal uso puede causar heridas PROHIBIDO...

Page 4: ...guraci n Caracter sticas t cnicas Detecci n inteligente de la calidad del aire sensor de part culas PM2 5 incorporado Panel de control t ctil muy c modo Pantalla digital PM2 5 temperatura humedad indi...

Page 5: ...rario o antihorario de manera que quede firme Encendido Pulse el bot n POWER en el panel frontal El aparato entra en el estado de trabajo inicial Selecci n de funciones Pulsando el bot n Settings se a...

Page 6: ...n al sensor inductivo lo que podr a causar errores Si observa una medici n muy desviada del rango normal le recomendamos que tome como referencia el valor PM2 5 ofrecido por los servicios meteorol gi...

Page 7: ...parato a otra habitaci n para volver a probar Peque os cambios del dato de humedad o temperatura Se est utilizando el aparato en un rea demasiado grande Utilice el aparato en una habitaci n con el tam...

Page 8: ...e insulation even cause fire Take out the plug and clean it with dry cloth Please remove the plug from the socket if not using for a long period ATTENTION Misusing may cause hurt FORBID Do not power t...

Page 9: ...iguration Technical features Air quality intelligent detection built in PM2 5 particle sensor Convenient control Digital display PM2 5 temperature humidity timer indicator intuitive and easy to unders...

Page 10: ...OWER icon on the product operating panel machine is entered the initial working status Function setting Press the Settings icon on the product operating panel The anions UV lamp and ozone can be chose...

Page 11: ...ed from the normal range here we advise you collect it as follow steps based on the weather forecast s PM2 5 numerical in your city 1 Open the window ventilated for 5 minutes PM2 5 sensor will re coll...

Page 12: ...e move the machine to another room to test again Small changes for humidity or temperature data Is the machine using area too big Please use this machine in applicable room If the problem still existe...

Page 13: ...Your trusted brand Talleres Mestraitua S L Txori erri Etorbidea 60 T 34 944530388 F 34 944711725 mestra mestra es www mestra es 48150 SONDIKA BILBAO ESPA A...

Reviews: