Mesto VAQ113 Installation Maintenance And Operating Instructions Download Page 4

 

IMO 

3/20

IMO-349 EN

4. 

TECHNICAL SPECIFICATION

Model 

VAQ113 

Operation type 

Internal Pilot operated 

Type 

5/2 single solenoid

Port

1/4" BSP / 1/4" NPT

Operating Pressure

2.5 to 10 kg/cm2 

5. 

MAINTENANCE

NOTE:

 The VAQ113 must be removed from installation 

prior to maintenance. All the connections/ports have to 

be disconnected prior to disassembly All the mountings, 

accessories and spare parts used or replaced must be 

original from RMEBS.

RMEBS recommends “RMEBS M 55” grease for greasing.  

Apply the grease with soft brush or similar In case of any 

difficulty consult RMEBS distributor.

1.  Install, operate and maintain as per the instructions and 

recommendations of this manual.

2.  Any deviation from the above will cease the 

responsibilities of RMEBS.

6. 

DISASSEMBLY

WARNING:

ALL ELECTRIC AND PNEUMATIC CONNECTIONS SHOULD BE 

REMOVED BEFORE STARTING DISASSEMBLY.

CAUTION:

 Do not place dismantled part on any diary/work 

bench but keep it on clean paper/cloth in same sequence as 

you have dismantled it.

NOTE:

 It is advisable to replace all the rubber parts using 

genuine RMEBS spare kit. Numbers in parentheses, ( ) 

indicate the bubble number (reference number) used on 

the RMEBS Assembly details and Part List.

6.1 

Disassembly of VAQ113

1.  Remove coil nut (26), after that remove solenoid coil (24). 

2.  Remove the 2 screws (20) by loosening them from EL 

cover (2), Cover plate (5) and simultaneously remove 

guide plunger (9). 

3.  Remove 4 bolts (17) from EL cover (2) and separate the EL 

cover assembly.

4.  Take out EL cover assembly, remove MA (7), MA plate (8) 

O-ring (17) and MA spring (11) then remove O-ring (18) 

and helping piston (4) too.

5.  Separate out spring cover (10) and spring (12) by 

removing bolt (19), as both covers are removed, spool kit 

is disengaged, pull spool kit gently out of the valve body.

NOTE:

 remove spool kit gently with non metallic hammer, 

do not hammer heavily on the spool, by this spool may get 

jammed in bore during this operation.

Summary of Contents for VAQ113

Page 1: ...IMO 349 EN 3 2020 SPOOL VALVE VAQ113 Installation Maintenance and Operating Instructions ...

Page 2: ...epresentative Addresses and phone numbers are printed on the back cover See also www metso com valves for the latest documentation SAVE THESE INSTRUCTIONS TABLE OF CONTENTS 1 INTRODUCTION 3 1 1 Definitions 3 2 LABEL DESCRIPTION 3 3 INSTALLATION PROCEDURE 3 4 TECHNICAL SPECIFICATION 4 5 MAINTENANCE 4 6 DISASSEMBLY 4 6 1 Disassembly of VAQ113 4 6 2 Exploded view 5 7 ASSEMBLY 6 7 1 Part list 7 8 PACK...

Page 3: ...rs in shipment failure due to power surge and cosmetic damage Improper or incorrectly performed maintenance or report voids this Limited Warranty For detailed warranty information please contact RMEBS MANUFACTERURS ENGINEERS PRIVATE LIMITED Manapadaroad Dombivli e Maharashtra India Pin 421204 1 1 Definitions WARNING IF NOT OBSERVED USER INCURS A HIGH RISK OF SEVERE DAMAGE TO PRODUCT AND OR FATAL I...

Page 4: ...LY CAUTION Do not place dismantled part on any diary work bench but keep it on clean paper cloth in same sequence as you have dismantled it NOTE It is advisable to replace all the rubber parts using genuine RMEBS spare kit Numbers in parentheses indicate the bubble number reference number used on the RMEBS Assembly details and Part List 6 1 Disassembly of VAQ113 1 Remove coil nut 26 after that rem...

Page 5: ...IMO 3 20 IMO 349 EN 5 6 2 Exploded view ...

Page 6: ... the lip seal 14 on the piston 4 apply a thin layer of grease on the lip seal 6 Insert the spring 12 and then insert spool kit 3 in to the body 1 and screw it using bolt 19 7 Separately make the assembly of EL cover fit the MA 7 on EL cover 2 with O ring 17 and spring 11 and fix it with MA plate 8 Finally fit filter 22 in given groove of EL cover 2 8 Place Piston 4 with lip seal 14 in EL cover 2 9...

Page 7: ...BR JET BLK 1 18 ORING 10 00 x 1 00 NBR JET BLK 1 19 DIN 912 M4 x 10 10 SS304 2 20 DIN 7991 M4 x 33 33 SS304 2 21 BALL DIA 2 IS 2898 2 22 FILTER VAD VAJ DSA SINTERED BR 1 23 DUST CAP FOR 1 4 ROTEX 1 24 COIL 12VDC WHETHERPROOF 1 25 SOCKET FOR COIL 1 26 COIL NUT FOR ZERO SIZE 1 8 PACKAGING STORE 1 When not in use VAQ113 ASSEMBLY should be kept in a sealed plastic bag in a cardboard box to prevent moi...

Page 8: ...Inc Metso Corporation Töölönlahdenkatu 2 P O Box 1220 00100 Helsinki Finland Tel 358 20 484 100 Neles Finland Inc Vanha Porvoontie 229 P O Box 304 FI 01301 Vantaa Finland Tel 358 20 483 150 Neles USA Inc 44 Bowditch Drive P O Box 8044 Shrewsbury MA 01545 USA Tel 1 508 852 0200 http contact metso com www metso com valves ...

Reviews: