16
Faults
8VHRQO\0(672VSDUHSDUWVDQGDFFHVVRULHV\RXZLOO¿QGVRPHLQWKHVSDUH
parts pouch [3],
)LJ
Fault
Cause
Remedy
No pressure builds up in
the device
The pump is not screwed on
tightly
Screw the pump on tightly
O-ring [12] on the pump is
faulty
)LJ
Replace the O-ring
Diaphragm [13] is defective
)LJ
Replace the diaphragm
/LTXLGÀRZVRXWRIWKH
pump
The valve disc [17] is dirty or
faulty
)LJ
Clean or replace the valve disc
The nozzle does not
spray even though pres-
sure is present
Filter [16]
)LJ
or /
and nozzle [14]
)LJ
is
clogged
&OHDQ¿OWHURUDQGQR]]OH
)LJV
Only spray, no atomi-
zation
Insert [15] missing
)LJ
Position the insert in the nozzle
The shut-off valve does
not close.
Liquid emerges without
the lever being activa-
ted..
Seal of the tension bolt [20]
not greased
Tension bolt [20] or
seal defective
)LJ
Unscrew screw [18] from the
shut-off valve [6] to remove the
lever [19].
)LJ
Unscrew screw seat [21] and
press out tension bolt [20].
)LJ
Clean and grease seal of the
tension bolt [20] or renew tensi-
on bolt [20].
)LJ
Install in reverse sequence.