KICKSPACE

HEATER

INSTALLATION INSTRUCTIONS

TYPE K & T

GENERAL DESCRIPTION

Kickspace

 

heaters are for use with forced hot water residential heating systems and consist of a copper tube, aluminum 

finned heating element, with an electric motor and blower of unique cross flow design. Their purpose is to deliver a 

comfortable stream of warmed air, at or near floor level, and their construction is extremely compact so minimum space 

is required for installation. The type K & T heaters are primarily used in horizonal floor installation, for example: under a 

kitchen counter cabinet, or bathroom sink enclosure. They are ideal for radiant systems with the use of a low temperature 

aquastat designed to turn the unit on at 110°F. Type W is for vertical mounting, fully recessed in the wall studs, with the 

air discharged upward through a flush mounted, louvered front panel. Type F is a surface mounted wall unit, with the 

air discharged evenly through a louvered front panel in an upward direction. All types have heating elements with 1/2" 

nominal (5/8 O.D.) copper tube connections, and 115V. electric blower motor, interwired with a 120°F (49°C) reverse 

acting aquastat that prevents operation until hot water is circulating. These units are NOT intended to be used on one or 

two pipe steam systems. See bottom of page 5. For gravity fed systems, it is recommended that a separate circulator pump 

be installed for the kickspace heater.

ATTENTION: READ THESE INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING TO INSTALL, OPERATE, OR 

SERVICE THE KICKSPACE

 

HEATERS! RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE.

INSPECT THE SHIPMENT IMMEDIATELY WHEN RECEIVED TO DETERMINE IF ANY DAMAGE HAS OCCURRED 

DURING SHIPMENT.

PRIOR TO INSTALLATION, CHECK FOR ANY VISIBLE DAMAGE.  MAKE CERTAIN THAT ANY LOOSE PARTICLES 

ARE REMOVED (ESPECIALLY IN THE BLOWER ASSEMBLY AREA).

SAFE TO USE WITH POTABLE WATER.

10/2019

Summary of Contents for Kickspace Series

Page 1: ...gh a flush mounted louvered front panel Type F is a surface mounted wall unit with the air discharged evenly through a louvered front panel in an upward direction All types have heating elements with...

Page 2: ...KICKSPACE MODEL 42 FIGURE 1 2 KICKSPACE MODEL 84 FIGURE 2 KICKSPACE MODEL 120 FIGURE 3 Dimensions shown in English and metric DIMENSIONAL DATA...

Page 3: ...ATION AND SERVICE IT IS RECOMMENDED THAT THIS ACCESS PANEL BE CONSTRUCTED SO ANNUAL CLEANING OF THE BLOWER FAN AND COIL FINS CAN BE EASILY ACCESSIBLE 3 At this location center and cut an opening in th...

Page 4: ...erated flow control or circuit setter can be placed between the two standard tee s in a one pipe system For consistent response of the reverse acting thermostat and effective outlet air temperature th...

Page 5: ...allation Figure 8 is a supply installation Figure 9 shows installation for the return side red ring between risers The return tee is installed opposite of the supply tee with the red ring between the...

Page 6: ...ower turns on check below for possible solutions a Water is not hot enough Check system water temp If radiant system low temperature aquastat may be needed b Water not circulating fast enough Kickspac...

Page 7: ...eck valve Do not return to bottom drain tapping Operation from steam boiler water is entirely possible as long as supply and return connection is installed be low level of water line on a steam boiler...

Page 8: ...anship of any installer of the Product This limited warranty is conditional upon a shipment to the Manufacturer of that part of the Product thought to be defective Goods can only be returned with prio...

Reviews: