Messtechnik dAV-C-HD Manual Download Page 7

dAV-C / dAV-R

Date:
09/19/13

Manual

Page 7

 5 

Trouble shooting

The following trouble shooting list is provided to assist you while having 
problems. It might let you use the system again without a long down time:

Error:

Possible reasons:

Solution:

No or erroneous 

transmission

Receiver does not 

receive an optical signal

Cables damaged or not
attached properly
Wrong optical fibers
(diameter)
Low battery

System turned off

Check optical fibers and 

connections, change
fibers if necessary
Connectors and cables
regarding damages
Use fiber with
62,5/125µm
Charge batteries

Turn on all devices

No transmission, noise 
at output

Low battery

No optical signal

Position of mic-/line IN 
switch is wrong

Charge batteries

Check for light at optical

output. Replace optical
fiber
Check switch position

Device cannot be 

turned on, cannot be 
charged 

Batteries damaged
Charger or cable
damaged
Batteries
over discharged 

Send device to us
Check / replace charger
and charging cable
Charge batteries, 
maybe use other 

charger (10 battery 
cells) 

High pitched whistle

Acoustic feedback

Turn down speaker

volume of receiver

Change position of

microphone

Common problems

Defective optical or 

electrical cables or 
connectors

Check connectors, fibers

and cables. Test with 
other ones. 

Replace cables

mk-messtechnik GmbH - Zeppelinstr. 1 - 73274 Notzingen - Tel: +(49) 7021-9566925

Summary of Contents for dAV-C-HD

Page 1: ...Manual dAV C r SD HD Camera system with digital transmission of analog A V signals...

Page 2: ......

Page 3: ...parts 8 7 Contact 9 Appendices Appendix I dAV C r SD A I 1 Appendix II dAV R r SD and setup with dAV C r SD operation and handling A II 1 Appendix III pan tilt unit PT 02 A III 1 Appendix IV camera m...

Page 4: ...era system Remote control of all camera functions option r Pan tilt unit PT 02 or PT 03 available together with option r Wide angle and close up lens External battery pack BP120 5f Shielded external p...

Page 5: ...1 4 tripod mount and two shielded battery connection cables with different lengths Depending on the range of use the battery pack can be placed close to the camera if high field strengths are suspecte...

Page 6: ...ue to self discharge issues with NiMH batteries recharge batteries before use if the system has not been used for a longer time Do not use cleaning agents or solvents to clean the devices only use a s...

Page 7: ...n on all devices No transmission noise at output Low battery No optical signal Position of mic line IN switch is wrong Charge batteries Check for light at optical output Replace optical fiber Check sw...

Page 8: ...o unit ID Check replace 6 Accessories Spare parts Part Order number Comment Optical fiber LWL 1 xm x length in m simplex External battery BP120 5f 12V 4Ah Pan tilt unit PT 02 Pan tilt unit for dAV Cr...

Page 9: ...l battery Seat box AV SB Made of wood height adjustable with 2D pan tilt for camera and place for external battery Manual MA dAV C R German or English 7 Contact mk messtechnik GmbH Zeppelinstra e 1 D...

Page 10: ...Date 09 19 13 dAV C dAV R Page 10 Manual mk messtechnik GmbH Zeppelinstr 1 73274 Notzingen Tel 49 7021 9566925...

Reviews: