background image

10

SETTING THE LIMITS FOR RIGHT OR LEFT HAND OPERATION AND FORCE

Travel Limits set how far your door goes up and down. Your opener must also be configured for right or left hand
installation, if not the door will rotate in the reverse direction.
Program Buttons: the Control Panel diagram in section 7 identifies the Control Buttons and LED layout.
Audible Beep: An audible “BEEP” also features with each button press. This feature can be turned OFF.
Courtesy light: during the programming sequence, the courtesy light will flash at half strength.
NOTE: The WeatherDrive MR550EVO opener is factory configured for right hand installation.

14

DN

DN UP

UP PP SS

11

22

33

132A2940

DN

DN UP

UP PP SS

11

22

33

132A2940

DN

DN UP

UP PP SS

11

22

33

132A2940

DN

DN UP

UP PP SS

11

22

33

132A2940

DN

DN UP

UP PP SS

11

22

33

132A2940

DN

DN UP

UP PP SS

11

22

33

132A2940

DN

DN UP

UP PP SS

11

22

33

132A2940

DN

DN UP

UP PP SS

11

22

33

132A2940

DN

DN UP

UP PP SS

11

22

33

132A2940

1. Program

Start

2. Left/Right

Setting

3. Accept

Setting

4. Set UP

Limit

5. Accept UP

Limit

6. Set DOWN

Limit

7. Accept

DOWN
Limit

8. Learn UP

Force

9. Learn

DOWN
Force

Flash

x 2

Flash

x 2

Flash

x 2

Flash

x 2

Flash

x 2

Flash

x 2

Full

light

BEEP

BEEP

BEEP

BEEP

BEEP

BEEP

BEEP

DOWN

DOWN

UP

UP

The opener will operate during this procedure. Make sure the door is clear of obstruction.
Ensure your hands are away from any moving parts before activating the door.

Setting the Right or Left Hand Operation:

Refer to the diagrams on the right for guidance.
Ensure the door is positioned halfway and the opener is
engaged.
Turn the opener Power ON, the courtesy light will turn ON.

1. Press the “P” button for 5 seconds until LED 3 comes ON,

as well as LED 2 or LED 1 will flash. For Right Hand
setting LED 2 will flash, and for Left Hand setting LED 1
will flash.

2. To change to the opposite setting, simply press the yellow

“S” button, and the opposite LED will flash.

3. When the correct hand setting is selected, Press and

Release the “P” program button to accept this
setting. (continue)

Setting the Door Limits:
4. Press and hold the “UP” button until the door

reaches the desired OPEN position (You can toggle
between the UP and DN buttons to move the door to
the correct position. Make sure there is enough room
for your vehicle to pass under)

5. Press and release the black “P” program button to

accept this setting.

6. Press and hold the “DN” button until the door

reaches the desired CLOSED position (You can
toggle between the UP and DN buttons to move the
door to the correct position.)

7. Press and release the black “P” program button to

accept this setting. (LED 2 should flash to indicate
you are now in Force Learn mode) (continue)

Setting the Force Automatically:
8. Press and release the “UP” button. The door will travel to

the OPEN position with LED 2 flashing.

9. Press and release the “DN” button. The door will travel to

the CLOSED position with LED 1 flashing. When fully
closed, LED 1 will stop flashing and the courtesy light will
change to full power.
(This process is now complete)

Setting the Force manually: (Only perform if Limits are
already set)
• Start with the door fully CLOSED.
• Press the “S” button twice to enter into force learn mode.

The Courtesy light will go to half strength, and Led 2 will
flash quickly.

• Press and release the “UP” button. The door will travel to

the OPEN position, then LED 1 will flash quickly.

• Press and release the “DN” button. The door will travel to

the CLOSED position, then LED 1 will stop and the
courtesy light will change to full power. (This process is
now complete)

BEEP

Summary of Contents for WeatherDrive MR550EVO

Page 1: ...d Operating Instructions Owners Copy Please keep these instructions for future reference This manual contains IMPORTANT SAFETY information DO NOT PROCEED WITH THE INSTALLATION BEFORE READING THOROUGHL...

Page 2: ...e building MUST BE AVAILABLE when using the Key Lockable Feature This Merlin Unit is rated to IP34 and has a UV stabilizer added however to ensure the best operation of the opener the installer should...

Page 3: ...om all practicable Protection against splashing and directions jets of water from all practicable Protection against low pressure practicable directions strong jet of water from all Protection against...

Page 4: ...TRUCTIONS WARNING Failure to comply with the following instructions may result in serious personal injury or property damage Read and follow all instructions carefully The garage door opener is design...

Page 5: ...ll and 5 5 mm drill bit 6 Philips head screwdriver 7 Marker pen 8 8 mm allen key 9 Door stand or similar device to safely support door not shown DOOR REQUIREMENTS 3 Ensure that there is at least 40 mm...

Page 6: ...oor is well balanced and not sticking or binding Disable all locks and remove any ropes connected to the garage door Lift the door to about halfway and then release it The door should remain spring ba...

Page 7: ...to SAVE the REMOTE CONTROLS 6 Key Lock used to lock the engage disengage mechanisim for commercial applications 7 LEDs 1 Program DOWN and Diagnostic code indicator Number 1 2 Program UP indicator 3 Di...

Page 8: ...es from the floor The cord may need to be extended DO NOT DISENGAGE THE OPENER TO MANUAL OPERATION WITH CHILDREN PERSONS OR OTHER OBJECTS INCLUDING MOTOR VEHICLES WITHIN THE DOORWAY The door is under...

Page 9: ...garage door security To remedy any ballooning place self tapping metal screws or rivets where the curtain leaves the roll Secure these through the curtain into the drum wheel at each end of the roll A...

Page 10: ...olt and door mounting bracket from the wall Install the opener Slide the opener over the door axle and engage the drive legs into the door drum wheel either side of a spoke Refit the door mounting bra...

Page 11: ...utton for 5 seconds until LED 3 comes ON as well as LED 2 or LED 1 will flash For Right Hand setting LED 2 will flash and for Left Hand setting LED 1 will flash 2 To change to the opposite setting sim...

Page 12: ...m out of the reach of children Ensure the manual release instruction card is attached to the rope as detailed in section 8 Read the safety instructions page 3 for further details concerning safety FIX...

Page 13: ...nuously If the door encounters an obstruction while closing the opener will return to the OPEN position and the waiting period will begin again To activate the Timer to Close Start with IRs installed...

Page 14: ...all control program into the opener before mounting the unit as detailed in the Wireless Programming section TRAVEL SPEED OPTIONAL 19 There are two travel speeds available for this opener Regular and...

Page 15: ...OW STANDBY mode Turn the mains power OFF Press and Hold both UP and DN buttons Turn ON mains power while both buttons are still pressed Courtesy light comes ON and after 5 seconds another 1 flash Rele...

Page 16: ...side this range the remote will operate as normal To Deactivate this feature 1 Start with the door fully CLOSED 2 Enter PET Activation mode by pressing the P and UP buttons together for 3 seconds figu...

Page 17: ...tesy light will flash twice 3 Enter a 4 digit personal identification number PIN of your choice on the keypad 4 Press and hold the ENTER button Check to see if the courtesy light flashes Release the E...

Page 18: ...n 13 Manually operate door If it is unbalanced or binding call for professional garage door service Check to be sure door opens and closes fully Set limits and or force if necessary SPECIAL NOTE Chamb...

Page 19: ...Keyless entry system 8 Model 760 Outside keyswitch 9 Model CM1702 Outside quick release steel fix 10 Model DMK1 Outside quick release brick fix 11 Model 774ANZ The Protector System TM IR Beams 25 4 5...

Page 20: ...5 002A1866 002A1867 002A1868 002A1869 002A1870 002A1872 002A1871 27 SPARE PARTS Information for Service Personnel 002A1865 002A1868 002A1866 002A1867 002A1869 002A1874 002A1872 002A1864 002A1873 002A1...

Page 21: ...ay not be on if the opener is in Standby mode Activate the door to temporarily exit standby mode and check lights are on constantly If the LEDs are flashing realign the beams 8 The door opens but will...

Page 22: ...ed or were momentarily obstructed Realign both sensors to ensure both LEDs are steady and not flickering Make sure nothing is hanging or mounted on the door that would interrupt the sensors path while...

Page 23: ...oods As part of this commitment we seek to provide reliable service and support for our goods and are pleased to provide you the original purchaser with this Chamberlain Limited Warranty The benefits...

Page 24: ...arranty or gomerlin co nz warranty Warranty Registration To validate your warranty you must complete the registration form online at gomerlin com au warranty or gomerlin co nz warranty 114A4818D 2017...

Reviews: