3
MAIN MENU
COMMAND
DESCRIPTION
LEARN MENU
LEARN DEVICE
Program a device to the receiver.
BLOCK LEARN DEVICE
Block program a range of devices to the receiver.
LEARN TO LOC #
Program a device to a 4-digit number location.
DELETE MENU
DELETE DEVICE
Delete a specified device that has been programmed to the receiver.
DELETE ALL DEVICES
Delete all programmed devices.
SUSPEND MENU
SUSPEND DEVICE
Temporarily disables the function of a specified device that has been
programmed to the receiver.
SUSPEND ALL DEVICES
Temporarily disables the function of ALL devices programmed to the
receiver.
UNSUSPEND DEVICE
Re-enable the function of a suspended device.
UNSUSPEND ALL DEVICES
Re-enable the function of ALL suspended devices.
QUERY MENU
LOC # USED
Displays a range of used locations starting from a specified location.
LOC # AVAILABLE
Displays a range of empty locations starting from a specified location.
LOC # SUSPENDED
Displays a range of suspended locations starting from a specified
location.
SETTINGS
PIN
Change or Delete the 6-digit PIN number for the receiver.
SERVICE INFO
Displays Merlin/Grifco 10-digit contact phone number.
FIRMWARE VERSION
Displays the current firmware version.
BEEP
Turn the audible feedback on or off.
MEMORY
DUPLICATE MEMORY Creates a memory backup. A backup memory module must be
installed.
RESTORE MEMORY
Restores a memory backup from a memory module.
NOTE: Content of memory backup module will over-write any
information already stored in the receiver memory.
RELAY
Sets the relay activation time from .25 to 1 second.
CONTRAST
Press Down or Up arrows to adjust LCD contrast.
LANGUAGE
Sets menu language: English (Default), Spanish, and French.
FACTORY DEFAULT
Reset receiver to factory default settings (deletes ALL codes).
PROGRAMMING COMMANDS
The table below describes the commands used to program the receiver.
DIAGNOSTICS
The receiver emits a series of audible beeps to signal programming and
error events. The table at right lists all of the events and their audible
notifications. The On/Off column indicates that the audible notification for
the
TO “RESET” PIN:
(follow the prompts on the display)
* Press “PPWR” to power the unit.
* Press “RESET” and identify the Customer Service Phone number for
your area.
* Press “NEXT” and record the “Device Serial # (5 digit)
At this point call the Customer Service centre where a temporary code will
be issued using the ”Device Serial #”.
(
NOTE:
You will need to identify yourself for security reasons).
* Press “NEXT” Enter the temporary code you have been issued.
* Enter
your
PIN (6 digit)
* Press “YES” Re Enter
your
PIN. Press “OK”.
event may be disabled in the BEEP SETTINGS menu.
EVENT
AUDIBLE
NOTIFICATIONS
ON/OFF
Key press
Single
YES
Successful Add
Double
Successful Delete
Triple
Successful Suspend
Double
Successful Unsuspend
Double
Master PIN entry error
Long
Programming error
Long
Location out of range
Long
Generic Success
Double
Generic Error
Long
Received unknown Tx
Slow
YES
Received known Tx
Double
YES
Received known suspended Tx
Long
YES
RELAY ON TIME
Sets the relay activation from MOMENTARY to CONSTANT
PRESSURE, for Keypads and Wireless Wall Buttons ONLY.
KEYPAD RELAY MODE