background image

DOCUMENT NON CONTRACTUEL

SPECIFICATIONS SUBJECT TO MODIFICATIONS

M E R L A U D

9 rue de La Briqueterie -  P.A.E. des FAUVETTES  - 95334 DOMONT CEDEX (FRANCE)
Tel. 01 39 91 77 78  -  Fax  01 39 91 90 66  -  

www.merlaud.com

-  merlaud@merlaud.com

e r l a u d

NOTICE D’UTILISATION ET DE DEPANNAGE / 

OPERATION & MAINTENANCE INSTRUCTIONS

COFFRET DE MODULATION

MODULATION SOURCES CASINGS

DO3-51-2067-AMC 02-V110204

Page 5/8

AMC 02

Code 2067

b) Absence of tape :

In case of tape‘s 

absence, the machine ignores the unloaded
drawer and let the next drawer start 

c) Jamming or cutting of tape : 

In case of 

tape’s jamming or cutting, the sequencial 
function will be cancelled and the machine 
will indicate teh absence of modulation: the
led will become red.

d) Blank tape : I

f a blank tape is used, the 

concerned drawer keeps playing for a 
complete cycle while the red lit led 
indicates absence of modulation.

e) Sequencial function: 

The use of TFMC 

or in case of tape’s jamming or cutting, the 
sequential function will be cancelled

f) Drawer’s location : 

Priorities and 

sequential function are independent of 
drawer’s location.

g) :Modulation indicator :

LED turns to red : Lack of modulation
LED  turns to green: Presence of modulation

3 TROUBLE SHOOTING

. LED doesn’t lit

: Check connection to 

mains supply

. LED doesn’t become green

: Check the 

presence of a recorded tape as well as the 
volume control position.Check if drawers are 
plugged correctly.

. Drawers LED blinking

: All TKC drawers 

are without tapes.

. Sequential function out of order

: Check if 

the tape in any of the drawers is out of order.

b) Absence d’une cassette : 

En cas 

d’absence d’une cassette le système 
ignore le tiroir non chargé et se comporte 
comme s’il n’existait pas.

c) Coupure ou blocage d’une cassette : 

En cas de coupure ou d’un blocage, le 
système se bloque en signalant l’absence 
de modulation. Le témoin s’allume en rouge.

d) Utilisation d’une cassette vierge : 

Le 

système continue la lecture de la cassette 
vierge jusqu’à la fin du cycle, mais en 
signalant l’absence de modulation. Le témoin 
s’allume en rouge.

e) Fonction séquentielle : 

L’utilisation 

d’un TFMD ou d’une bande coupée ou 
bloquée annule la fonction séquentielle

f) Ordre des tiroir : 

Les priorités n’auront 

aucun lien avec l’ordre des tiroirs

g) :Indicateur de modulation :

LED allumée en rouge : Absence de modulation
LED allumée en vert : Présence de modulation

3 DEPANNAGE

. La LED ne s’allume pas

: Vérifier le 

branchement secteur.

. La LED ne passe pas au vert 

: Vérifier la 

présence de cassettes enregistrées et la 
position du contrôle de volume. Vérifier si 

les tiroirs sont bien embrochés.

. Les LEDS des tiroirs TKC clignotent

Absence de cassette de tous les tiroirs TKC

. Fonction séquentielle bloquée

: Vérifier si 

la bande dans l’un des tiroirs est coupée.

Summary of Contents for AMC 02

Page 1: ...symétrique avec télécommande commutable par déplacement d un cavalier interne en entrée Haut Niveau Aux pouvant recevoir un pupitre type DC1A Bande Passante 40 10000 Hz Rapport Signal Bruit 50 dB Niveau de Sortie 10dB 245mV Code 2067 Entrée Mic 60dB Entrée Aux 10dB Alimentation 240V 50 60Hz Standard 19 2U EQD2U EQG2U Dimensions LxHxP mm 440x88x375 Poids 5Kg Black painted sheet steel casing to fit ...

Page 2: ...amme 1 3 Sortie Signal audio 1 2 Masse 6 Sortie 0 dB 3 Sortie Signal audio 1 2 Masse 4 Télécommande TMAD 7 Entrée antenne coaxiale 75 Ohms 8 Alimentation externe 1 2 Télécommande TMAD mise à la masse 3 4 Alimentation 24V avec fusible interne 1A 9 Embase secteur La masse est connectée à la terre du secteur 10 Fusible Fusible 1A retardé 5 Input 1 a Balanced Mic 1 3 Audio signal inputs 2 Common refer...

Page 3: ...67 AMC 02 V110204 Page 3 8 AMC 02 Code 2067 Fig 3 b a Entrée Auxiliaire Entrée Micro Symétrique c d Entrée Aux Sortie Alim 15V Input Aux output supply 15V Input Balanced Mic Input Aux Sortie FM programme 1 1st FM program output S1 S2 1 2 C7 C6 C10 C3 C4 16 R15 R4 R26 R1 R2 R5 R3 C2 C1 D3 R22 C11 R11 R14 R10 R9 R8 R12 Q1 R13 15V DC1 R6 88 IC1 IC2 C9 C5 Aux C8 D4 TELECOM REMOTE S1 S2 R25 R23 R21 R19...

Page 4: ...e modulation 2 FONCTIONNEMENT Brancher le coffret AMC 02 sur le secteur ou sur une batterie Voir tableau d utilisation a Lecture La lecture des bandes aura lieu en continu en 2 ou 4 pistes Le tiroir de gauche démarre en premier suivi du tiroir voisin après la lecture complète de la première bande 2 ou 4 pistes 1 INSTALLATION 1 Connect sources to appropriate inputs 2 Install adequately the drawers ...

Page 5: ...oesn t become green Check the presence of a recorded tape as well as the volume control position Check if drawers are plugged correctly Drawers LED blinking All TKC drawers are without tapes Sequential function out of order Check if the tape in any of the drawers is out of order b Absence d une cassette En cas d absence d une cassette le système ignore le tiroir non chargé et se comporte comme s i...

Page 6: ...ctionnement normal d un lecteur d alarme TMAD Prioritaire sur l entrée micro Fonctionnement normal d un lecteur de slogang avec lecteur d alarme prioritaire par télécommande TMAD Prioritaire sur micro qui sera prioritaire sur TMAD TKC démarre le premier et continue en lecture permanente si le TFMC est éteint En cas d allumage du TFMC le programme passe sur radio après un cycle complet de la bande ...

Page 7: ...comended for economical and technical reasons Permanent operation Microphone with remote overrides the TFMC Unrecomended for economical reasons Normal slogan tape machine operation Microphone with remote overrides the TMAD Normal alarm tape machine operation TMAD Overrides the microphone TMAD overrides TMAD and microphone Microphone with remote overrides TMAD If TFMC is Offf TKC starts in a contin...

Page 8: ...39 91 90 66 www merlaud com merlaud merlaud com e r l a u d NOTICE D UTILISATION ET DE DEPANNAGE OPERATION MAINTENANCE INSTRUCTIONS COFFRET DE MODULATION MODULATION SOURCES CASINGS DO3 51 2067 AMC 02 V110204 Page 8 8 AMC 02 Code 2067 DOCUMENT NON CONTRACTUEL SPECIFICATIONS SUBJECT TO MODIFICATIONS SCHEMA WIRING ...

Reviews: