COPYRIGHT
1995 MERIT INDUSTRIES, INC.
4
SCORPION™ 9000 MANUAL
PM17170C
GAME OPERATION
Target Alarm
If darts are thrown while the game is in idle mode,
the target alarm will sound and the overhead light
will go off (for a few minutes). This feature can be
disabled by turning off DIP switch 1-8.
Clearing Credits
To clear credits, first power off the game. Next, press
and hold the PLAYER CHANGE button while turning
the game back on. When the “STUC BUTTON”
message appears on the overhead, release the
PLAYER CHANGE button and the credits will be
cleared.
Free Play
A 2-pin connector is provided on the main harness to
allow you to enable free play. See Figures 1 and 2
for the location of the connector.
If you wish to enable free play, you will need (2) .062
male molex pins, a connector housing and .18
gauge wire. Insert the molex pins into the connector
housing and attach it to the existing 2-pin connector
on the main harness. Loop the wire as seen in
Figure 3. Free play mode is enabled as long as the
connection is made.
If you want the ability to enable/disable free play
without having to connect and disconnect the wires,
Merit suggests you insert a switch. To do this, simply
cut the looped wire and solder the ends to the switch
(see Figure 3).
Figure 1 - LOCATION OF "FREE PLAY"
CONNECTOR ON MAIN HARNESS
(UPRIGHT MODEL)
Figure 2 - LOCATION OF "FREE PLAY"
CONNECTOR ON MAIN HARNESS
(WALL MOUNT MODEL)
Figure 3 - "FREE PLAY" CONNECTION
CONNECTOR & .18
GAUGE WIRE
STG01 CPU BOARD
MAIN HARNESS 2-PIN CONNECTOR
STG01 CPU
BOARD
MAIN HARNESS 2-PIN
CONNECTOR
CONNECTOR & .18
GAUGE WIRE
MOLEX 2-PIN HOUSING
MOLEX 2-PIN HOUSING
.18 GAUGE WIRE WITH
MOLEX PINS
SWITCH