441 Sedan
•
Owner’s Manual
Chapter 11: Electrical Systems
91
Parallel Switch (If Equipped with Dual Shore Power)
When only one dockside outlet is available, you can use the parallel switch to provide power to both lines.
1. Connect to shore power as described in the
Connecting to Shore Power
section on the previous page.
2. Switch the parallel switch (transfers power from line 1 to line 2)
On
instead of the “SHORE POWER 2”
master breaker.
3. Turn
On
the individual component breakers as required.
•
When using the parallel switch do
NOT
exceed 30 total amps.
•
The amperage of each component breaker is shown on the breaker itself.
•
The voltage on each line can be read on the voltmeter on the 110-volt AC master panel.
NOTI CE