6 Troubleshooting, Maintenance, Equipment Return
6.1 Troubleshooting
Problem
Possible causes
ant. open
message
no antenna connected
Alarm LED on
antenna cable defective
surge arrester defective
wrong antenna connected
ant. short
message
short-circuit in antenna cable or connector
Alarm LED on
antenna cable defective
surge arrester defective
wrong antenna connected
bad time
message
poor antenna location
Alarm LED on
6.2 Cleaning
Before cleaning the equipment make sure that the primary voltage has been
DANGER
→
disconnected.
Should it be necessary to clean the exterior of the equipment, use only a dry
cloth.
To avoid damages to the electrostatically sensitive electronic parts, no clean-
ing of internal parts should be performed.
6.3 Returning a Unit
To return a unit for service, please contact
at any of the addresses
found on the back cover of this document and obtain an
equipment return
code
(ERC).
Please do not return a unit to
whitout an ERC.
can’t track
ATTENTION
→
units returned whitout an ERC and will not assume any responsibilities in this
case.
The equipment shall be sent in its original package or an equally suitable one
in order to protect it against impacts and moisture.
Send the unit to the address supplied in the ERC. Please include sender’s iden-
tification and ERC on the outside of the package.
Summary of Contents for tima 2P
Page 1: ...tīma 2P 2R GPS Master Clocks Reference Manual tima reference en v3 14 20099 ...
Page 8: ...4 tīma 2P 2R GPS Master Clocks Reference Manual ...
Page 14: ...10 tīma 2P 2R GPS Master Clocks Reference Manual ...
Page 20: ...16 tīma 2P 2R GPS Master Clocks Reference Manual ...
Page 32: ...28 tīma 2P 2R GPS Master Clocks Reference Manual ...
Page 34: ...30 tīma 2P 2R GPS Master Clocks Reference Manual ...
Page 40: ...36 tīma 2P 2R GPS Master Clocks Reference Manual ...
Page 50: ...46 tīma 2P 2R GPS Master Clocks Reference Manual ...
Page 55: ......
Page 56: ...mergedK GmbH Reuchlinstr 10 11 10553 Berlin Germany Tel 49 30 38305710 www mergedk com ...