Mercury 600.652 Instruction Manual Download Page 2

 

 

I

.      Safety information 

Read the following safety information carefully before attempting to operate or service the meter. 

Use the meter only as specified in this manual; otherwise, the protection provided by the meter may be 

impaired. 

z

 

Environment conditions 

 

Altitude up to 2000 meters 

 

Relatively humidity 90% max. 

 

Operation Ambient 0~40

 

z

 

Maintenance & Clearing 

 

Repairs or servicing not covered in this manual should only be performed by qualified personnel. 

 

Periodically wipe the case with a dry cloth. Do not use abrasives or solvents on this instruments. 

z

 

Safety symbols 

        Meter is protected throughout by double insulation or reinforced insulation. 

When servicing, use only specified replacement parts. 

Comply with EMC 

 

II. General Description

 

Thank you for using our Sound Level Meter. To ensure that you can get the most from it, we recommend 

that you read and follow the manual carefully before use. 

This unit conforms to the IEC651 type 2, ANSI S1.4 type 2 for Sound Level Meters. 

This Sound Level Meter has been designed to meet the measurement requirements of safety Engineers, 

Health, Industrial safety offices and sound quality control in various environments. 

z

 

Ranges from 30dB to 130dB at frequencies between 31.5Hz and 8 KHz. 

z

 

Display with 0.1dB steps on a 4-digits LCD. 

z

 

With two equivalent weighted sound pressure levels, A and C. 

 

III Specifications

 

Standard applied ....................................................... IEC651 type 2, ANSI S1.4 type 2 

Frequency range: .................................................................................... 31.5Hz~8KHz 

Measuring level range:..................................................................................30~130dB 

Frequency weighting: ............................................................................................  A/C 

Microphone: ....................................................1/2 inch electret condenser microphone 

Calibration:............... Electrical calibration with the internal oscillator (1kHz sine wave) 

Display: ................................................................................................... LCD (4 digits) 

Resolution: .........................................................................................................  0.1dB 

Display Up data: ..............................................................................................0.5 sec. 

Time weighting: .............................................................. FAST(125mS), SLOW(1 sec.) 

Level ranges: ..............................................................Lo: 30-100dB  /  Hi: 60-130dB 

Accuracy: ............................................................ + 1.5dB (under reference conditions) 

Alarm function: ........................................... “OVER” is show when input is out of range 

Maximum hold:........   Hold readings the Maximum Value, with decay < 1dB/3minutes. 

Power supply: ................................ One 9V battery, 006P or IEC 6F22 or NEDA 1604. 

Power life: .....................................................................  About 50hrs(alkaline Battery) 

Operation temperature :  ........................................................... 0 to 40

(32 to 104

Operation humidity: .................................................................................. 10 to 90%RH 

Storage temperature: ...........................................................  -10 to 60

( 14 to 140

Storage humidity: ...................................................................................  10 to 75%RH 

Dimensions: ...........................................................................210(L)X55(W)X32(H)mm 

Weight:...................................................................................... 230g(including battery) 

 

Summary of Contents for 600.652

Page 1: ...Lo 35 100dB Hi 65 130dB F S dBA dBC O A C 600 652 Sound Level Meter Instruction Manual Gebruiksaanwijzing Gebrauchsanleitung Mode d Emploi...

Page 2: ...signed to meet the measurement requirements of safety Engineers Health Industrial safety offices and sound quality control in various environments z Ranges from 30dB to 130dB at frequencies between 31...

Page 3: ...g Lo Low Range 30 100dB Hi High Range 60 130dB BAT Low Battery Power ON OFF button I Turn the meter power ON OFF Backlight Button Turn the meter backlight ON OFF MAX Hold button MAX The max Hold posit...

Page 4: ...nals 2 To achieve more accurate measurement use an extension cable to separate the Microphone from the main body so that the effect of unexpected sound reflection can be eliminated 3 Calibrate the ins...

Page 5: ...iligheids medewerkers die zich vooral bezighouden met geluidskwaliteitscontroles en normen Specificaties z Bereik tussen 30dB en 130dB bij frequenties tussen 31 5Hz en 8 KHz z Display met 0 1dB stappe...

Page 6: ...0 100dB Hi High Range 60 130dB BAT Lege batterij 3 ON OFF toets l Zet de meter hier mee aan uit 4 Backlight toets Schakel de blacklight hier mee aan uit 5 A weighting C weighting keuze toets A C A A W...

Page 7: ...prake is van hoge temperaturen of hoge vochtigheid 4 Vermijd hoge vibraties en leg de meter droog weg 5 Verwijder de batterij wanneer de meter lange tijd niet gebruikt wordt Meting 1 Zet de meter aan...

Page 8: ...51 Typ 2 ANSI S1 4 Typ 2 f r Schallpegelmessger te Messbereiche von 30dB bis 130dB bei Frequenzen zwischen 31 5Hz und 8kHz 4 stelliges LCD Display mit 0 1 dB Schritten 2 Wichtungen A und C 3 Technisch...

Page 9: ...gro en Anteil tiefer Frequenzen 6 Reaktionszeitwahlschalter F Schnelle Reaktion f r normale Messungen schnell ver nderlicher Ger uschpegel S Langsame Reaktion Zur Messung des durchschnittlichen Pegel...

Page 10: ...nicht bei Hitze oder gro er Feuchtigkeit lagern oder benutzen 5 Das Mikrofon trocken halten und schwere Ersch tterungen vermeiden 6 Bei l ngerem Nichtgebrauch die Batterie entfernen und das Ger t tro...

Page 11: ...SCHNELL Bereich 30 bis 100dB Lo oder 60 bis 130dB Hi Messart MAX Hold und Data Hold desaktiviert 2 Das Mikrofon vorsichtig ins Loch des Eichmasses einf hren 3 Das Batteriefach ffnen und die Batterie...

Page 12: ...ervice L appareil est conforme aux normes IEC651 type 2 ANSI S1 4 type 2 pour d cibelm tres Plages de mesure de 30dB 130dB des fr quences comprises entre 31 5Hz et 8kHz Affichage LCD 4 digits par incr...

Page 13: ...quences 6 S lecteur de temps de mesure F r ponse rapide pour des mesures normales bruits forte variation S r ponse lente pour v rifier le niveau moyen d un bruit fluctuant 7 S lecteur de plage de niv...

Page 14: ...il sous la chaleur ou une forte humidit Maintenez le microphone au sec et vitez des vibrations fortes Retirez la pile et conservez l appareil dans un endroit sec s il ne sera pas utilis pendant une du...

Page 15: ...A Temps de r ponse RAPIDE Plage 30 100dB Lo ou 60 130dB Hi Mode de mesure MAX Hold et Data Hold d sactiv s 2 Ins rez le microphone doucement dans le trou du calibre 3 Ouvrez le compartiment pile et r...

Page 16: ......

Reviews: