600.107UK
capacitors are fully discharged.
CONTINUITY TEST
1.
Connect the BLACK test lead to the “COM” jack
and the RED
to the “VΩ” jack (Note: The polarity of the red test lead is
positive “+”).
2.
Set the range switch to range
3.
Connect the test leads across the load to be measured.
4.
If the circuit resistance is lower than about 30
±20Ω, the built
-
in buzzer will sound.
DIODE MEASUREMENT
1.
Connect red lead to “VΩmA”, black lead to “COM”.
2.
Set RANGE switch to “
” position.
3.
Connect the red test lead to the anode of the diode to be
measured and black test lead to cathode.
4.
The meter will show the approximate forward voltage
of the diode. If
the connections are reversed, “1” will be
shown on the display.
CABLE TESTER
This network cable tester can be used to scan and judge the
continuation property of double-twisted cable. Both automated and
manual operations are available.
Main performance:
1.
Test unshielded or shielded network cable, telephone lines and
USB cables.